Abstract
Background: Congenital heart disease is a major cause of mortality in small babies and children, where early diagnosis is very important for proper treatment and improving clinical outcomes. Unfortunately, conventional auscultation-based diagnosis methods mostly rely on expert interpretation that limits their scalability in very far and mountain regions having comparatively low-resource environments. To address these major problems, we propose a deep learning-based method with a spectral minimax-guided context attention transformer framework. Methods: The input signal to the framework is phonocardiogram signals. The proposed framework leverages the optimal use of spectral representation of heart sounds to capture time-frequency features and introduces a novel minimax transformation block designed for cardiac sound mapping analysis. The minimax attention block enhances spectral discrimination by mapping features to a relatively high-dimensional space to improve stratification, thereby compressing them to reduce sensitivity to repetition and noise. Additionally, we employ a cosine-oriented contextual attention module to improve feature representation, adaptively adjusting spatial and temporal features. This approach allows the proposed framework to highlight important acoustic differences and more effectively understand interlayer variations in heart sound patterns. The design also incorporates window-based focus and hierarchical feature clustering to efficiently represent local and global correlations. Results: We conducted experiments on the heart sound dataset known as the ZCHSound. We found that the proposed framework outperforms the basic methods on many assessment metrics. Conclusion: Although some challenges remain in multi-class classification with unbalanced datasets, the results demonstrate the potential of simple spectral learning and cosine-oriented attention to improve the automated diagnosis of congenital heart disease.
Keywords: deep learning, health analytics, transfermer framework, congential heart disease
1. Introduction
Congenital heart disease (CHD) is the most prevalent congenital abnormality worldwide and remains a major contributor to neonatal and childhood mortality [1,2,3,4]. It encompasses a wide spectrum of structural defects affecting the heart and great vessels, with a substantial global burden, particularly in low- and middle-income regions where access to specialized cardiac care is limited. Timely and precise diagnosis is essential, since delayed identification may result in significant clinical issues, such as stunted growth, neurological impairments, and heightened mortality. Nonetheless, inequalities in healthcare facilities and diagnostic proficiency persistently obstruct prompt CHD screening.
CHD includes a very wide spectrum of structural heart defects. According to the WHO report [5], more than 30 types of CHD have been reported, but most have not been fully explored by researchers. The most frequently diagnosed lesions in these are Atrial Septal Defect (ASD), Ventricular Septal Defect (VSD), Patent Foramen Ovale (PFO), and Patent Ductus Arteriosus (PDA). Our current experimental validation dataset also considers only five classes. Globally, VSD is considered the most common and frequent CHD in infants. Similarly, ASD is also very prevalent, particularly in grown-up kids, due to late diagnosis. On the other hand, PDA is more common in premature infants. Studies also reported that PDA is more prevalent at high altitudes. Overall, 60% of CHDs in the Tibetan area are PDA [6]. It is also observed that the distribution of CHD varies among various geographical regions due to genetic variations, environmental factors, nutritional effects, and socio-economic factors. For example, VSD is reported more frequently in Asian and Middle Eastern countries, whereas ASD and PFO detection rates are higher in Europe and North America. Reports also show that CHD is more common in low-income countries than in high-income countries; please see Figure 1, ref. [5].
Figure 1.

People living with CHD according to income regions from year 1990 to 2023.
Phonocardiography (PCG) offers a non-invasive, economical, and portable method for evaluating cardiac function by recording acoustic signals linked to heart activity. When PCG signals are converted into a time-frequency representation, such as a spectrogram, they show complex spectro-temporal patterns that provide important insights for diagnosing disease states. Despite this potential, the high variability of heart sounds, noise, interference patterns, and subtle differences between normal and abnormal cardiac features make PCG diagnosis difficult. Furthermore, acoustic PCG spectrograms exhibit high-dimensional features with complex relationships between frequency bands, which makes feature extraction and representation a challenging task.
Support vector machines (SVMs), k-nearest neighbor (kNN) algorithms, and decision trees are examples of traditional machine learning methods for heart sound classification that mainly rely on manually generated features and often fail to accurately capture the complex spectral-time dynamics present in PCG signals. Convolutional neural networks (CNNs), a recent development in deep learning, have dramatically increased performance by enabling automatic feature extraction from unprocessed or variable inputs. Although CNN-based models are good at detecting spatial patterns, they are unable to capture long-term dependencies and general contextual correlations, which are essential for understanding subtle variations in heart sounds associated with congenital heart diseases.
One of the major health problems in low-income countries is CHD. We are working on a long-term project to help medical professionals use the latest AI-based technologies for CHD diagnosis. One such effort led to the present paper. Our previous posts on the same topic include [7,8,9,10]. Our ongoing efforts to use AI and deep learning to treat CHD are also an extension of this study. We have used a hybrid method combining CNNs and vision transformers (ViTs) in our latest publication, which we call HViTs [10]. Through self-focusing methods, transformer-based architectures–particularly ViTs–have shown impressive success in modeling global dependencies. They are ideal for examining complex time-frequency representations due to their ability to record long-range interactions. However, using direct transformer models for PCG-based CHD diagnosis has several drawbacks, including (1) underemphasis on discriminative color features, (2) susceptibility to noise and redundant information, and (3) limited ability to capture subtle contextual differences in similar cardiovascular conditions.
We propose a minimax-guided context attention transformer (MG-CAT) framework for automated CHD diagnosis to overcome the drawbacks of HViTs described above. A unique minimax transformation (MMT) block designed for PCG spectrum analysis is introduced in the proposed method. By projecting input features into a high-dimensional space to maximize spectral discrimination, this block improves feature representation. This is followed by a compression stage that reduces redundancy and suppresses noise. The proposed model can selectively highlight informative frequency components while preserving important cardiac properties.
We use a guided dynamic context attention (CS-DCA) module to improve feature learning for cosine matching. The CS-DCA unlike traditional attention techniques, dynamically reweights spatial context features according to their similarity in the learned feature space. This enables the model to more accurately reveal subtle differences and relationships between classes in PCG patterns. This process increases robustness under noisy conditions and is particularly good at distinguishing acoustically similar CHD instances. The architecture also uses a window-based dynamic focusing method to efficiently model local and global relationships while maintaining computing efficiency.
The main contributions of this work are summarized as follows:
To improve the representation of spectral and temporal features, we propose a new MG-CAT framework for CHD diagnosis that combines a spectral minimum transform block and a dynamic contextual attention converter.
To enhance the model’s ability to detect subtle acoustic fluctuations and inter-class relationships in PCG signals, we introduce a cosine similarity-driven dynamic context attention module that adaptively reweights relevant information.
Using an expert-annotated paediatric PCG dataset, we validate the proposed framework and show that it performs better and is more robust than existing baseline techniques.
2. Related Work
CHD diagnosis using AI remains a relatively underdeveloped area. Different diagnostic strategies are adapted by medical practitioners for CHD recognition. The initial screening is normally conducted with a pulse oximeter (POX), followed by a stethoscope. Some advanced methods include magnetic resonance imaging (MRI), electrocardiogram (EKG), and echocardiogram (ECH). Each of these methods provides various advantages; for example, cost-effectiveness when using POX, and very detailed and comprehensive anatomical structures in Computed Tomography Scan (CTS). Some of these methods also pose serious challenges; for example, the need for expert knowledge and an experienced doctor. Medical practitioners use different diagnostic strategies to recognize CHD. In this section of the paper, we discuss these diagnostic modalities to address CHD diagnosis using AI.
2.1. Computed Tomography
Ecabert et al. [11] proposed an early model-based method for CHD using the CTS modality. The method uses a 3D Generalized Hough Transform (GHT) for localization, then piecewise affine transformation, and lastly deformable adaptation. The authors of the paper reported results with a mean surface-to-surface error of 0.82 mm, which showed high accuracy for segmenting CTS of a heart into its major components. Later, Khalil et al. [7] proposed a model named Cardiac Deep Learning Model (CDLM). The CDLM employs a 3D U-Net framework with graph matching for vessel classification. According to the authors of the paper, better heart segmentation results in blood pool and vessels being shown. Also, CDLM shows notable accuracy in aortic segmentation with high mean Dice scores across heart structures, surpassing earlier methods. While CTS may seem promising in CHD diagnosis, collecting data for training and the affordability of equipment may suggest that it may not be the most effective way for heart defect classification. Jingjing et al. [12] proposed a method that uses heart sound recording for CHD diagnosis. The authors named their proposed method AI-assisted auscultation (AI-AA). The proposed method (AI-AA) uses CNNs to classify the time-frequency representation of heart sounds. Results are reported with Sensitivity (0.97%), Specificity (0.89%), and Accuracy (0.96%).
2.2. Ultrasound
Qiao et al. [13] used ultrasound images as a modality for CHD recognition. The proposed method uses a specialized transformer model named Multi-Scale Gated Axial-Transformer Network (MSGATNet). Reported results are Precision, Recall, and Accuracy of 0.96%, 0.94%, and 0.95%, respectively. Chen et al. [14] used EKG signals and wavelet-transformed features. According to the authors, the ROC-AUCs were 0.915 (internal test sets) and 0.917 (external test sets). The specificity value obtained was 0.881, which, according to the authors, outperforms previously reported results by a huge margin. Another work reported by Du et al. [15] used a Residual of Residual (RoR) Network for CHD recognition, with the modality being the EKG signal. Reported Accuracy, Sensitivity, and Specificity values are 92.45%, 74.73%, and 94.07%, respectively.
2.3. Phonocardiogram Data
An attention-based transformer is combined with CNNs in the paper proposed by Hassanuzzaman et al. [16]. The authors used the PCG signal as a processing modality. The classification task was limited to binary classification (normal vs. abnormal). A small dataset of 484 samples was used in these experiments. According to the authors, promising results are reported, with accuracy, sensitivity, specificity, F1-score, and AUC values of 92.3%, 98.3%, 83.3%, 03.0% and 0.964, respectively.
Lightweight CNN models are introduced by Chen et al. [17] again utilizing PCG data. The framework introduced was a hierarchy of two architectures: a dense block architecture and a clique-based model. This model also uses a small dataset of 528 samples. According to the paper, the dense-based model shows better results, with accuracies of 96.21% and 98.77%, specificities of 98.08% and 98.77%, and precisions of 91.67% and 98.77%, respectively. The second architecture (clique-based) achieved an accuracy of 91.68%, specificity of 89.17%, sensitivity of 93.40%, and precision of 88.96%. This work also addresses CHD as a binary classification problem. According to the authors, one main advantage of this method is its use of limited computational resources, making it a good fit for real-time CHD diagnosis.
Fourier transform, along with Cepstrum analysis, is used by Yadav et al. [18] for CHD recognition. Downsampling of the recorded signal has been performed from 2000 Hz to 1000 Hz for band-pass filtering. This also reduces noise and speeds up processing. The mean and maximum values of the Fourier transform ratio are used to help classify CHD and non-CHD cases. Additionally, the authors used the mean values of the cepstrum coefficients. PhysioNet was used as a dataset for experiments. The dataset size in this case was also small, with just 100 recordings. SVM was used as a classifier. An Accuracy of 95%, a sensitivity of 100 %, and a Specificity of 90%, respectively.
In the literature, CHD recognition using machine learning or AI is not a well-explored or mature area. We present a summary of different methods in Table 1. Table 1 not only presents a summary of the literature, but it also tells us which kind of modality is used for each method.
Table 1.
Different methods reporting CHD using machine learning.
| Paper | Method and Application |
|---|---|
| Lee et al. [19] | Used CNN on EKG for CHD classification |
| Haq et al. [20] | Applied customized 1D-CNN on PCG signal |
| Mayour et al. [21] | Employed CNN on ECG data to predict ventricular dysfunction |
| Shi et al. [22] | Developed traditional machine learning models using ICD codes for CHD identification |
| Sharifi et al. [23] | Utilized EfficientNetV2 on chest X-ray images for CHD classification |
| Jia et al. [24] | applied RF and KNN on clinical data for CHD prediction |
| Zhixin et al. [25] | Implemented 3D/2D U-Net for cardiac structure segmentation in CHD |
| Han et al. [26] | Applied ResNet18 on imaging data for CHD classification |
| Cheng et al. [27] | Employed ResNet18 on Ech for CHD detection |
| Marelli et al. [28] | Combined RF and SVM for CHD prediction |
| Pace et al. [29] | Applied 3D U-Net for segmentation in CHD EKG |
| Siefkes et al. [30] | Used RF, Logistic Regression, and Gradient Boosting for CHD classification |
| Qiao et al. [31] | Proposed a hybrid model for CHD diagnosis using cardiac imaging |
| Xuu et al. [32] | Used ResNets for feature extraction in CHD diagnosis |
| Sapitri et al. [33] | Applied YOLOv7 for real-time CHD detection in ultrasound |
| Arnaout et al. [34] | Used ensemble of ResNet50 networks on fetal Ech for complex CHD detection |
| Yang et al. [35] | Combined ResNet50 and LSTM on sequential cardiac data for CHD analysis |
| Jiang et al. [36] | Applied CNNs on imaging for automated CHD classification |
| Tan et al. [37] | Used Bayesian models for probabilistic CHD risk assessment |
| Gearhart et al. [38] | Applied CNNs on ECG for CHD-related dysfunction detection |
| Truong et al. [39] | Used Random Forest on clinical data for CHD screening |
| Oliveira et al. [40] | Used CNNs on echocardiograms for CHD classification |
| Kavitha et al. [41] | Applied MLDDP framework for multi-level CHD diagnosis |
| Wu et al. [42] | Implemented YOLOv5 for fetal CHD ultrasound |
| Lv et al. [12] | Employed SVM for CHD classification from clinical data |
| Belinha et al. [43] | Combined ANN and Decision Trees for CHD prediction |
| Tan et al. [44] | Used SVM on features for CHD diagnosis |
| Gong et al. [45] | Generated synthetic CHD data using GANs |
| Karimi et al. [46] | Applied GANs for data augmentation and CHD segmentation |
| Thomas et al. [47] | Used SVM for CHD classification |
| Rani et al. [48] | Applied ANN on clinical parameters for CHD detection |
| Bozkurt et al. [49] | Employed CNNs on EKG videos for CHD detection |
| Linag [50] | Combined CNN with Logistic Regression for CHD diagnosis |
3. Proposed Method and Data
3.1. Minimax Guided Context Attention Transformer (MG-CAT)
The proposed MG-CAT framework for automated CHD diagnosis using pediatric PCG signals is designed to jointly model local spatio-spectral acoustic characteristics and long-range contextual dependencies. An overview of the end-to-end architecture is illustrated in Figure 2.
Figure 2.

Overview of the proposed MG-CAT framework for CHD diagnosis using PCG signals.
Let the input non-stationary PCG signal be denoted as . To capture both temporal dynamics and frequency-domain acoustic structures, is transformed into a two-dimensional spectro-temporal representation via the Short-Time Fourier Transform (STFT):
| (1) |
where H and W represent the time and frequency dimensions, respectively, and C denotes the channel dimension (initialized to for single-channel acoustic inputs). This transformation represents cardiac acoustic phenomena—such as transient murmurs, ejection clicks, and valve closure irregularities—as spatial energy patterns in the time-frequency plane.
The input spectrogram X is partitioned into P non-overlapping patches of size and linearly projected into a latent embedding space:
| (2) |
where denotes the embedding dimension.
3.2. Theoretical & Technical Comparison with Existing Paradigms
To clarify the conceptual and technical contributions of the proposed components, Table 2 details how the MMT block and the CS-DCA module differ from conventional channel-recalibration mechanisms and standard self-attention modules.
Table 2.
Comparison of the proposed MG-CAT with existing paradigms.
| Component | Baseline Paradigms | Proposed MG-CAT Modules | Technical Advantage in PCG Analysis |
|---|---|---|---|
| Spectral Recalibration Mechanism | Pure unconstrained dynamic range compression via global average pooling and unconstrained non-linear MLPs. | Formulated as a dual-stage information filter that minimizes intra-class spectral noise while maximizing inter-class diagnostic margin. | Effectively suppresses low-frequency ambient/friction artifacts while preserving subtle, high-frequency murmur harmonics. |
| Attention Formulation | Relies on scalar product magnitude (), highly sensitive to acoustic loudness variation. | Integrates normalized angular similarity () with dot-product magnitude and relative position bias. | Provides scale-invariant alignment across varying recording amplitudes and stethoscope pressures. |
| Contextual Reweighting | Global softmax normalization that can smooth out temporal transients in deep layers. | Adaptive window-level rescale operator driven by mean local attention energy. | Prevents feature over-smoothing and preserves fine-grained transient events like S1/S2 heart sound splitting. |
3.3. Spectral Minimax Transformation (MMT) Block
Pathological heart sounds typically present as low-amplitude, localized spectral aberrations embedded within ambient physiological noise. Traditional channel-attention mechanisms (e.g., Squeeze-and-Excitation) adjust channel weights purely based on absolute energy levels, making them vulnerable to acoustic interference. The MMT part is shown in Figure 3.
Figure 3.

Spectral minimax transformation block for CHD diagnosis.
Inspired by minimax optimization and feature recalibration theory, the MMT block operates as a trainable spectral filter designed to minimize redundant intra-class noise while maximizing inter-class spectral margin:
| (3) |
Given an intermediate feature tensor , the MMT block executes two distinct phases
3.3.1. 1. Min Phase (Acoustic Redundancy & Noise Compression)
Spatial information across time-frequency bins is aggregated into a global channel descriptor vector using channel-wise spatial pooling:
| (4) |
This aggregation compresses local spectral variations, minimizing sensitivity to uncorrelated background noise and stationary acoustic artifacts.
3.3.2. 2. Max Phase (Discriminative Spectral Expansion & Recalibration)
To maximize the separation between distinct pathological signatures, the descriptor z is passed through a bottleneck dimensionality reduction and non-linear restoration mechanism:
| (5) |
| (6) |
where and are learnable weight matrices, r denotes the reduction ratio, and represents the sigmoid activation function. The output scaling vector acts as an adaptive spectral gate. The recalibrated feature map is obtained by element-wise channel multiplication:
| (7) |
This dual-phase formulation forces the network to attenuate non-informative frequency channels () while amplifying clinically relevant acoustic indicators ().
3.4. Cosine Similarity-Guided Dynamic Context Attention (CS-DCA)
We present our proposed CS-DCA as part of the algorithm in Figure 4. Standard vision transformers utilize dot-product self-attention:
| (8) |
Figure 4.

Proposed CS-DCA for CHD diagnosis.
Because the dot product scales with token magnitudes, standard attention maps are sensitive to absolute acoustic amplitude and recording volume. To overcome this limitation, the CS-DCA module incorporates normalized angular similarity directly into the attention formulation.
Given window-partitioned input tokens (where w is the local window size), projection matrices compute Query (Q), Key (K), and Value (V) representations:
| (9) |
3.4.1. Scale-Invariant Angular Alignment
To evaluate spatial-spectral patterns independently of recording gain or signal loudness, the normalized cosine similarity matrix is computed:
| (10) |
where denotes -norm normalization along the feature dimension. Cosine similarity bounded within captures the geometric alignment between token representations.
3.4.2. Hybrid Attention Score Formulation
The composite attention affinity matrix combines dot-product magnitude, angular orientation, and 2D relative positional bias :
| (11) |
where is a learnable scaling parameter that balances magnitude-based and angular attention.
3.4.3. Dynamic Context Scaling & Output Projection
To adaptively modulate token interaction based on context, a dynamic context scaling vector is calculated by taking the mean attention energy across tokens within the local window:
| (12) |
The scaled attention matrix is obtained via Hadamard product (⊙):
| (13) |
The final output is generated via softmax normalization and value aggregation:
| (14) |
| (15) |
3.5. Hierarchical Architecture and Classification Stage
Each transformer layer combines MMT spectral recalibration, CS-DCA contextual attention, Layer Normalization (LN), and Multi-Layer Perceptrons (MLP) with residual connections:
| (16) |
| (17) |
where the MLP block consists of two linear layers with GELU non-linearity:
| (18) |
To construct hierarchical multi-scale feature maps, patch merging layers aggregate adjacent patch tokens:
| (19) |
where is a trainable projection matrix.
The resulting multi-scale representation is flattened and passed to a linear classification head to produce predicted class probabilities :
| (20) |
| (21) |
3.6. Dataset and Experimental Setup
The framework was evaluated using the open-source ZCHSound dataset, a dedicated pediatric PCG collection containing recordings from 1259 subjects (aged newborn to 14 years) collected across three pediatric medical centers. Details about the dataset are shown in Figure 5. Acoustic recordings were acquired at a sampling rate of 8000 Hz using a Childcare G-100 digital stethoscope, with durations ranging from 11 to 30 s per file.
Figure 5.

Overview of the ZCHSound dataset used in this study.
The dataset contains five diagnostic target classes:
Normal (533 samples)
Ventricular Septal Defect (VSD)
Atrial Septal Defect (ASD)
Patent Foramen Ovale (PFO)
Patent Ductus Arteriosus (PDA, minority class with 32 samples)
The dataset is partitioned into high-quality (941 recordings, ) and low-quality (318 recordings, ) subsets. Data splits follow standard protocols, utilizing a 60% training, 20% validation, and 20% test split, alongside a 10-fold cross-validation scheme to evaluate generalization.
4. Results and Discussion
This section summarizes the experimental setup and the reported outcomes and their comparison with previous results on the same dataset.
Implementation and Experimental Setup: All experiments were implemented using PyTorch 2.1 on an NVIDIA RTX 3090 GPU (24 GB VRAM). To guarantee strict end-to-end reproducibility, a fixed random seed of 42 was applied to Python 3.15, NumPy, and PyTorch random generators across all data partitioning, weight initializations, and cross-validation routines. To address class imbalance during training, we utilized a Class-Weighted Cross-Entropy Loss, where each class weight is computed as for target classes. The full architectural and training hyperparameter configurations are summarized in Table 3.
Table 3.
Experimental and Hyperparameter Setup Details for the Proposed MG-CAT Model.
| Category | Hyperparameter | Value/Specification |
|---|---|---|
| STFT Preprocessing | FFT Window Length () | 512 samples ( at ) |
| Hop Size | 128 samples (, overlap) | |
| Window Function | Hann window (257 frequency bins) | |
| Architecture | Patch Size | |
| Embedding Dimension () | 256 | |
| Transformer Layers | 6 | |
| Attention Heads () | 8 () | |
| Feed-Forward Dimension | 1024 | |
| Dropout Rate | ||
| Optimization | Optimizer | AdamW (, weight decay ) |
| Initial Learning Rate | ||
| Learning Rate Scheduler | Cosine Annealing () | |
| Batch Size | 32 | |
| Epochs/Early Stopping | 100 epochs (15 epochs patience) | |
| Training Setup | Data Augmentation | SpecAugment (), Gaussian noise, time-shift |
| Imbalance Handling | Class-Weighted Cross-Entropy Loss | |
| Random Seed | 42 (fixed across splits and initializations) |
Discussion
For CHD diagnosis using PCG data, the only dataset available in the research community is ZCHSound [24]; therefore, we will compare only with ZCHSound. The dataset used in this study is the most recent (published in 2024), and aside from the original paper, our previous work [51] only reports its results. In the following paragraphs, we summarize the results and our remarks.
A limitation of the present study is that the evaluation was conducted using the publicly available ZCHSound dataset, which, to the best of our knowledge, is currently the only publicly available pediatric phonocardiogram (PCG) dataset specifically developed for congenital heart disease (CHD) classification. Although ZCHSound contains recordings collected from three pediatric medical centers, all experiments in the present study are based on the same dataset and therefore do not constitute independent external validation. The 10-fold cross-validation employed in this study provides an assessment of the robustness of the proposed framework within the available cohort; however, it cannot fully establish generalizability to independent patient populations, institutions, recording devices, or acquisition conditions. Therefore, the results should be interpreted as evidence of the effectiveness of the proposed MG-CAT framework on the ZCHSound cohort rather than as evidence of readiness for clinical deployment or large-scale real-world screening. Independent multicenter validation using datasets collected from diverse clinical settings and patient populations will be necessary to further establish the generalizability, scalability, and clinical applicability of the proposed framework.
Despite the strong performance demonstrated through rigorous 10-fold cross-validation on the ZCHSound dataset, the current study lacks independent external validation across multi-center, heterogeneous cohorts, which remains a vital prerequisite for broader clinical translation. Furthermore, in the context of automated pediatric screening, the potential consequences of false-negative predictions carry severe clinical implications—including delayed therapeutic interventions, progressive physiological deterioration, and heightened infant mortality—thereby emphasizing that high sensitivity and robust threshold optimization are essential safeguards for reliable deployment in resource-limited environments.
The pre-processing step improves the quality of heart-sound representations, thereby enhancing model performance. The method converts raw PCG data into a time-frequency representation, aligned with human auditory perception. In addition, frame segmentation and Mel-filter projection together produce a concise, information-rich representation that demonstrates increased robustness to noise.
Although imaging-based techniques are highly accurate, their application in resource-limited settings is limited by expensive equipment and reliance on professional interpretation. Recent advances in CNNs and transformer-based models have helped signal-based methods–particularly those that use PCG recordings–provide a more accessible option. Progress has been further accelerated by the availability of large expert-annotated PCG datasets, highlighting the PCG-based deep learning framework as a potential route for automated and scalable early CHD screening.
For evaluating our model, we use the following parameters. We must mention here that we use micro-averaging while reporting all the following results in our paper.
For the same dataset [51], we improve our results and the algorithm we proposed in our previous work. ViTs are preferred over traditional deep learning models due to their superior ability to represent global and long-range relationships. Interpretation of cardiac sound signals depends on this global, long-range connection. In the same vein, transformer-based models outperform models in terms of generalization and robustness. In our previous work, we used a hybrid CNN-ViT technique to exploit global context and extract local features. All things considered, we outperform previous research on the ZCHSound [24] dataset. However, in a multi-class classification problem, we had a problem with subordinate classes. The performance of the proposed model (MG-CAT) is compared with other published results on the same dataset in Table 4. The HViT-based architecture performs well in the binary CHD diagnosis test, but in the multiclass case, it performs worse. This discrepancy is primarily driven by the dataset’s significant class imbalance, where subtypes such as PDA and PFO have far fewer recordings than ASD or VSD. HViTs rely heavily on large, balanced datasets because their self-attention mechanism lacks the inductive bias of convolution; consequently, attention maps for minority classes tend to be unstable and skewed toward majority-class patterns. This imbalance is reflected in the confusion matrix as well, where rare subtypes exhibit the largest misclassification rates. Compared with HViTs, we achieved better results across minor classes as well.
Table 4.
Performance comparison of the proposed model MG-CAT with HViTs [51] and ZCHSound [24] for binary and multiclass classification tasks.
For multi-class data, confusion matrices are normally used for model evaluation. It is a two-dimensional table, where one dimension corresponds to the true labels and the other dimension corresponds to the predicted labels. The confusion matrix (Figure 6) shows that the model can discriminate almost perfectly between normal and abnormal states for binary classes Figure 6a. MG-CAT demonstrates strong overall classification performance, particularly for the Normal and VSD classes, which achieve the highest number of correct predictions at 99 and 32 instances, respectively. Similarly, Figure 6b shows the multi-class classification results. Figure 6b analyses the results with data distribution, where we see that a limited number of samples for CHD subtypes might contribute to the worse results. For example, the class PDA with the fewest samples (32) in the dataset performed worst, while the normal class with 533 samples performed best. Thus, this pattern indicates that the classification’s lower performance on multi-class data stems from insufficient data, making it difficult for the proposed model to effectively learn differences between CHD subtypes.
Figure 6.

Reported confusion matrices for binary and multi-class problems.
In the confusion matrix, the diagonal elements confirm that the majority of samples across all conditions—including those with congenital heart defects such as PFO, ASD, and PDA—are accurately identified. The matrix demonstrates high diagnostic reliability despite some ambiguity, with a relatively low number of serious misclassifications between pathological and normal categories. By explicitly directing the attention mechanism towards both general contextual information and spatial patterns characteristic of the categories, the proposed MG-CAT framework exhibits better robustness towards under-represented categories than HViT models. The model is encouraged to learn more balanced representations across categories using a min-max directed contextual attention technique, which reduces the dominance of the most represented category features during training. The separation of categories in the latent space is enhanced as a result of under-represented subtypes such as PDA and PFO receiving strong feature reinforcement. In addition, the model can capture subtle acoustic features that are often missed in traditional transducer construction due to context clustering. This improves the overall performance of multi-category classification and reduces the misclassification rate.
Figure 7 shows the binary classification performance of the proposed model for CHD, with consistently high precision, recall, F1-score, and precision for both normal and abnormal classes, resulting in an overall accuracy of 97%. These results show consistent differences between normal and abnormal heart sounds. Similar differences in performance between CHD subtypes can be seen in Figure 8, which shows the multiclass classification results. High accuracy and F1 scores are used for standard classification. Low recall scores and F1 scores indicate decreased performance for demographics including ASD and PDAs. Obvious PFO and VSD produce intermediate results, minimizing the effects of class asymmetry and subtle acoustic differences between CHD subtypes. The results show that although the model is very good at screening for bilateral CHD, multiclass assessment is difficult and requires more comprehensive subtype-specific data and effective error control techniques.
Figure 7.

Binary class performance comparison on MG-CAT, ZCHSound [24], and HViTs [51].
Figure 8.

Multiclass classification performance comparison on MG-CAT, ZCHSound [24], and HViTs [51].
According to experimental results, MG-CAT regularly outperforms HViTs in terms of precision, recall, and F1-score. In difficult and under-represented categories such as ASD, VSD, and PDA, where the baseline model showed low sensitivity and inconsistent performance, the improvement was particularly evident. MG-CAT reduces misclassification rates across several CHD categories, improves feature generalization, and enhances class separation by leveraging minimally guided contextual attention. Compared with the HViT model, these results demonstrate that the combination of threshold optimization and context-aware learning significantly improves transformer-based medical image classification and establishes MG-CAT as a more reliable and efficient framework for automated CHD.
For a more detailed comparison, we compared our reported accuracy and specificity with previously reported methods (i.e., ZCHSound [24] and HViTs [51] in Figure 9a,b. Similarly, sensitivity and F1-score are compared in Figure 10a,b. Both Figure 9 and Figure 10 demonstrate the performance improvements resulting from the proposed evaluation strategy. The figures show consistent gains in precision, recall, F1-score, and overall accuracy. This indicates enhanced predictive consistency. These figures exhibit a clear upward shift reflecting improved discriminative capability and class separability.
Figure 9.

Accuracy and Specificity comparison of MG-CAT, ZCHSound [24], and HViTs [51].
Figure 10.

Sensitvity and F1-score comparison of MG-CAT, ZCHSound [24], and HViTs [51].
5. Conclusions
In this study, we proposed the MG-CAT framework for automated CHD diagnosis based on PCG recordings. The proposed method successfully captures clinically important cardiac sound patterns using the time-frequency spectral representation obtained by STFT. We presented an MMT module that uses adaptive channel recalibration to reduce noise and redundancy while enhancing critical spectral components to improve discriminative feature learning. In addition, we developed the CS-DCA technique to enhance the contextual modeling of the transformer cluster. The proposed module uses similarity-aware weighting as opposed to traditional subjective attention, allowing for more reliable modeling of subtle acoustic differences and inter-class correlations in heart sound signals. The MG-CAT architecture effectively captures local and global dependencies while maintaining computational efficiency when combined with a hierarchical window-based attention strategy.
According to extensive experiments conducted on the ZCHSound dataset, the proposed model consistently outperforms existing baselines, including previous hybrid vision transformer technologies. When it comes to binary and multiclass classification, MG-CAT performs better compared to previous algorithms. These results support the effectiveness of similarity-based contextual attention and minimum-based spectrum enhancement in enhancing diagnostic performance.
Despite these encouraging results, multiclass classification problems remain due to significant class imbalance and small sample sizes for several CHD subtypes, such as PDA and PFO. To further increase the robustness and generalizability of pediatric practical screening applications, future research will focus on advanced data augmentation methods, disparity-aware learning methods, and validation of large multicenter data sets.
Acknowledgments
The Researchers would like to thank the Deanship of Graduate Studies and Scientific Research at Qassim University (https://www.qu.edu.sa) for financial support (QU-APC-2026).
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding author.
Conflicts of Interest
The author declares no conflict of interest.
Funding Statement
This research received no external funding.
Footnotes
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
References
- 1.Zhang X., Feng Y., Ren J., Jin X. Global, regional, and national burden of congenital heart disease, 1990–2021: A systematic analysis for the global burden of disease study 2021. Eur. J. Pediatr. 2025;184:253. doi: 10.1007/s00431-025-06085-w. [DOI] [PubMed] [Google Scholar]
- 2.Al-Shawki Y.M.A.A. The global burden and diagnostic challenges of undiagnosed congenital heart disease in resource-limited settings: A comprehensive review from 2019 to 2025. Risk Manag. Healthc. Policy. 2026;17:125–140. [Google Scholar]
- 3.Vicente M., Lopes M.S., Pires A. Congenital Heart Disease in Sub-Saharan Africa: Equity Crisis and Global Test for Cardiovascular Medicine. JACC Case Rep. 2026;31:108163. doi: 10.1016/j.jaccas.2026.108163. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Ahamad S., Tulsi A., Singh P., Kukshal P. Familial recurrence and phenotype concordance in non-syndromic congenital heart disease: A tertiary care center study from India. Int. J. Health Sci. 2026;20:202–209. doi: 10.25259/ijhs_114_2026. [DOI] [Google Scholar]
- 5.Kumar R.K., Di Cesare M., Shrikhande S., Pendrick E., Zheleva B., Adeoye M., Evans N., Hall T., Hasan B., Yao N.-A., et al. World Heart Report 2026: Congenital Heart Disease. World Heart Federation; Geneva, Switzerland: 2026. [(accessed on 21 October 2026)]. Available online: https://world-heart-federation.org/wp-content/uploads/whf-report-2026-digital.pdf. [Google Scholar]
- 6.Białkowski J., Głowacki J., Zabal C., Garcia-Montes A., Bermudez-Canete R., Flores-Arizmendi R., Sagado-Sandova A., Diaz de Leon H., Delagadillo R.M., Kreutzer J. Patent ductus arteriosus at low and high altitudes: Anatomical and haemodynamic features and their implications for transcatheter closure. Kardiol. Pol. 2011;69:431–436. [PubMed] [Google Scholar]
- 7.Khan K., Ahmad T., Uddin I. 2023 15th International Conference on Software, Knowledge, Information Management and Applications (SKIMA) IEEE; Piscataway, NJ, USA: 2023. Cardiac deep learning model for congenital heart disease recognition; pp. 293–297. [Google Scholar]
- 8.Khan K., Ullah F., Syed I., Ullah I. The role of machine learning in congenital heart disease diagnosis: Datasets, algorithms, and insights. arXiv. 20252501.04493 [Google Scholar]
- 9.Khan K., Ullah F., Syed I., Ali H. Accurately assessing congenital heart disease using artificial intelligence. PeerJ Comput. Sci. 2024;10:e2535. doi: 10.7717/peerj-cs.2535. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Khan K., Irfanud D., Khan R.U. Hybrid vision transformer framework for congenital heart disease diagnosis. Sci. Rep. 2026;16:16724. doi: 10.1038/s41598-026-45133-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Ecabert O., Peters J., Schramm H., Lorenz C., von Berg J., Walker M.J., Vembar M., Olszewski M.E., Subramanyan K., Lavi G., et al. Automatic model-based segmentation of the heart in CT images. IEEE Trans. Med. Imaging. 2008;27:1189–1201. doi: 10.1109/tmi.2008.918330. [DOI] [PubMed] [Google Scholar]
- 12.Lv J., Dong B., Lei H., Shi G., Wang H., Zhu F., Wen C., Zhang Q., Fu L., Gu X., et al. Artificial intelligence-assisted auscultation in detecting congenital heart disease. Eur. Heart J.–Digit. Health. 2021;2:119–124. doi: 10.1093/ehjdh/ztaa017. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Qiao S., Pang S., Sun Y., Luo G., Yin W., Zhao Y., Pan S., Lv Z. SPReCHD: Four-chamber semantic parsing network for recognizing fetal congenital heart disease in medical metaverse. IEEE J. Biomed. Health Inform. 2022;28:3672–3682. doi: 10.1109/jbhi.2022.3218577. [DOI] [PubMed] [Google Scholar]
- 14.Chen J., Huang S., Zhang Y., Chang Q., Zhang Y., Li D., Qiu J., Hu L., Peng X., Du Y., et al. Congenital heart disease detection by pediatric electrocardiogram based deep learning integrated with human concepts. Nat. Commun. 2024;15:976. doi: 10.1038/s41467-024-44930-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Du Y., Huang S., Huang C., Maalla A., Liang H. Proceedings of the 2020 IEEE International Conference on Progress in Informatics and Computing (PIC) IEEE; Piscataway, NJ, USA: 2020. Recognition of child congenital heart disease using electrocardiogram based on residual networks; pp. 145–148. [Google Scholar]
- 16.Hassanuzzaman M., Hasan N.A., Mamun M.A.A., Alkhodari M., Ahmed K.I., Khandoker A.H., Mostafa R. Proceedings of the 2023 45th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) IEEE; Piscataway, NJ, USA: 2023. Recognition of pediatric congenital heart diseases by using phonocardiogram signals and transformer-based neural networks; pp. 1–4. [DOI] [PubMed] [Google Scholar]
- 17.Chen D., Xuan W., Gu Y., Liu F., Chen J., Xia S., Jin H., Dong S., Luo J. Automatic classification of normal–abnormal heart sounds using CA convolutional neural network and long-short term memory. Electronics. 2022;11:1246. doi: 10.3390/electronics11081246. [DOI] [Google Scholar]
- 18.Yadav A., Dutta M.K., Travieso C.M., Alonso J.B. Proceedings of the 2018 IEEE International Work Conference on Bioinspired Intelligence (IWOBI) IEEE; Piscataway, NJ, USA: 2018. Automatic classification of normal and abnormal PCG recording heart sound recording using Fourier transform; pp. 1–9. [Google Scholar]
- 19.Lee Y.S., Chung H.T., Lin J.J., Hwang M.S., Liu H.C., Hsu H.M., Chang Y.T., Peng S.J. Prediction of significant congenital heart disease in infants and children using continuous wavelet transform and deep convolutional neural network with 12-lead electrocardiogram. BMC Pediatr. 2025;25:324. doi: 10.1186/s12887-025-05628-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Haq I.U., Husnain G., Ghadi Y.Y., Innab N., Alajmi M., Aljuaid H. Enhancing pediatric congenital heart disease detection using customized 1D CNN algorithm and phonocardiogram signals. Heliyon. 2025;11:e42257. doi: 10.1016/j.heliyon.2025.e42257. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Mayourian J., El-Bokl A., Lukyanenko P., La Cava W.G., Geva T., Valente A.M., Triedman J.K., Ghelani S.J. Electrocardiogram-based deep learning to predict mortality in paediatric and adult congenital heart disease. Eur. Heart J. 2025;46:856–868. doi: 10.1093/eurheartj/ehae651. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Shi H., Book W.M., Ivey L.C., Rodriguez F.H., III, Raskind-Hood C., Downing K.F., Farr S.L., McCracken C.E., Leedom V.O., Haynes S.E., et al. A Generalized Machine Learning Model for Identifying Congenital Heart Defects (CHDs) Using ICD Codes. Birth Defects Res. 2025;117:e2440. doi: 10.1002/bdr2.2440. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Sharifi S., Donyadadi A. Detection and diagnosis of congenital heart disease from chest X-rays with deep learning models. Int. J. Appl. Data Sci. Eng. Health. 2025;1:1–9. [Google Scholar]
- 24.Jia W., Wang Y., Chen R., Ye J., Li D., Yin F., Yu J., Chen J., Shu Q., Xu W. ZCHSound: Open-source zju paediatric heart sound database with congenital heart disease. IEEE Trans. Biomed. Eng. 2024;71:2278–2286. doi: 10.1109/tbme.2023.3348800. [DOI] [PubMed] [Google Scholar]
- 25.Li Z., Luo G., Ji Z., Wang S., Pan S. CHD-CXR: A de-identified publicly available dataset of chest x-ray for congenital heart disease. Front. Cardiovasc. Med. 2024;11:1351965. doi: 10.3389/fcvm.2024.1351965. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Han P.-L., Jiang L., Cheng J.-L., Shi K., Huang S., Jiang Y., Jiang L., Xia Q., Li Y.-Y., Zhu M., et al. Artificial intelligence-assisted diagnosis of congenital heart disease and associated pulmonary arterial hypertension from chest radiographs: A multi-reader multi-case study. Eur. J. Radiol. 2024;171:111277. doi: 10.1016/j.ejrad.2023.111277. [DOI] [PubMed] [Google Scholar]
- 27.Cheng M., Wang J., Liu X., Wang Y., Wu Q., Wang F., Li P., Wang B., Zhang X., Xie W. Development and Validation of a Deep-Learning Network for Detecting Congenital Heart Disease from Multi-View Multi-Modal Transthoracic Echocardiograms. Research. 2024;7:0319. doi: 10.34133/research.0319. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Marelli A.J., Li C., Liu A., Nguyen H., Moroz H., Brophy J.M., Guo L., Buckeridge D.L., Tang J., Yang A.Y., et al. Machine learning informed diagnosis for congenital heart disease in large claims data source. Cardiovasc. Adv. 2024;2:100801. doi: 10.1016/j.jacadv.2023.100801. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Pace D.F., Dalca A.V., Geva T., Powell A.J., Moghari M.H., Golland P. Medical Image Computing and Computer-Assisted Intervention–MICCAI 2015. Springer; Berlin/Heidelberg, Germany: 2015. Interactive whole-heart segmentation in congenital heart disease; p. 18. Part III. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Siefkes H., Oliveira L.C., Koppel R., Hogan W., Garg M., Manalo E., Cresalia N., Lai Z., Tancredi D., Lakshminrusimha S., et al. Machine Learning–Based Critical Congenital Heart Disease Screening Using Dual-Site Pulse Oximetry Measurements. J. Am. Heart Assoc. 2024;13:e033786. doi: 10.1161/jaha.123.033786. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Pachiyannan P., Jasińska M., Gołuński R. A Novel Machine Learning-Based Prediction Method for Early Detection and Diagnosis of Congenital Heart Disease Using ECG Signal Processing. Technologies. 2024;12:4. doi: 10.3390/technologies12010004. [DOI] [Google Scholar]
- 32.Xu X., Jia Q., Yuan H., Qiu H., Dong Y., Xie W., Yao Z., Zhang J., Nie Z., Li X., et al. A clinically applicable AI system for diagnosis of congenital heart diseases based on computed tomography images. Med. Image Anal. 2023;90:102953. doi: 10.1016/j.media.2023.102953. [DOI] [PubMed] [Google Scholar]
- 33.Sapitri A.I., Nurmaini S., Rachmatullah M.N., Tutuko B., Darmawahyuni A., Firdaus F., Rini D.P., Islami A. Deep learning-based real time detection for cardiac objects with fetal ultrasound video. Inform. Med. Unlocked. 2023;36:101150. doi: 10.1016/j.imu.2022.101150. [DOI] [Google Scholar]
- 34.Arnaout R., Curran L., Zhao Y., Levine J.C., Chinn E., Moon-Grady A.J. An ensemble of neural networks provides expert-level prenatal detection of complex congenital heart disease. Nat. Med. 2021;5:882–891. doi: 10.1038/s41591-021-01342-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Yang H., Pan J., Wang W., Guo T., Ma T. Application of artificial intelligence-based auxiliary diagnosis in congenital heart disease screening. Anatol. J. Cardiol. 2023;4:205. doi: 10.14744/anatoljcardiol.2022.1386. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Jiang X., Yu J., Ye J., Jia W., Xu W., Shu Q. A deep learning-based method for pediatric congenital heart disease detection with seven standard views in echocardiography. World J. Pediatr. Surg. 2023;6:e000580. doi: 10.1136/wjps-2023-000580. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Jyothi S., Vanisree K. Proceedings of the 2016 Second International Conference on Computational Intelligence Communication Technology (CICT) IEEE; Piscataway, NJ, USA: 2016. Congenital heart septum defect diagnosis on chest X-ray features using neural networks; pp. 265–269. [Google Scholar]
- 38.Gearhart A., Goto S., Deo R.C., Powell A.J. An automated view classification model for pediatric echocardiography using artificial intelligence. J. Am. Soc. Echocardiogr. 2022;12:1238–1246. doi: 10.1016/j.echo.2022.08.009. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Truong V.T., Nguyen B.P., Nguyen-Vo T.-H., Mazur W., Chung E.S., Palmer C., Tretter J.T., Alsaied T., Pham V.T., Do H.Q., et al. Application of machine learning in screening for congenital heart diseases using fetal echocardiography. Int. J. Cardiovasc. Imaging. 2022;5:1007–1015. doi: 10.1007/s10554-022-02566-3. [DOI] [PubMed] [Google Scholar]
- 40.Oliveira J., Renna F., Costa P.D., Nogueira M., Oliveira C., Ferreira C., Jorge A., Mattos S., Hatem T., Tavares T., et al. The CirCor DigiScope dataset: From murmur detection to murmur classification. IEEE J. Biomed. Health Inform. 2021;6:2524–2535. doi: 10.1109/jbhi.2021.3137048. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Kavitha D., Renumadhavi C.H. An efficient multilayer deep detection perceptron (MLDDP) methodology for detecting testicular anomalies with or without congenital heart disease (TACHD) J. Supercomput. 2022;3:4057–4072. doi: 10.1007/s11227-021-04008-8. [DOI] [Google Scholar]
- 42.Wu H., Wu B., He S., Liu P. Proceedings of the IEEE International Conference on Systems, Man, and Cybernetics. IEEE; Piscataway, NJ, USA: 2022. Congenital heart defect recognition model based on YOLOV5. [Google Scholar]
- 43.Belinha S., Oliveira B.M., Rodrigues P.P. Congenital Heart Disease Detection Using Clinical Data and Auscultation Heart Sounds: A Machine Learning Approach; Proceedings of the SMARTERCARE Workshop, Intelligent Systems (IA); Milan, Italy. 29 November 2021. [Google Scholar]
- 44.Tan J., Au A., Meng Q., FinesilverSmith S., Simpson J., Rueckert D., Razavi R., Day T., Lloyd D., Kainz B. Advances in Simplifying Medical UltraSound (ASMUS 2020) Springer; Berlin/Heidelberg, Germany: 2020. Automated detection of congenital heart disease in fetal ultrasound screening. [Google Scholar]
- 45.Gong Y., Zhang Y., Zhu H., Lv J., Cheng Q., Zhang H., He Y., Wang S. Fetal congenital heart disease echocardiogram screening based on DGACNN: Adversarial one-class classification combined with video transfer learning. IEEE Trans. Med. Imaging. 2019;4:1206–1222. doi: 10.1109/tmi.2019.2946059. [DOI] [PubMed] [Google Scholar]
- 46.Karimi-Bidhendi S., Arafati A., Cheng A.L., Wu Y., Kheradvar A., Jafarkhani H. Fully-automated deep-learning segmentation of pediatric cardiovascular magnetic resonance of patients with complex congenital heart diseases. J. Cardiovasc. Magn. Reson. 2020;1:80. doi: 10.1186/s12968-020-00678-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47.Thomas B.T., Binu N.J., Varghese A., Peter A.A., Thomas G., Kurupath V. 2020 International Conference on Futuristic Technologies in Control Systems & Renewable Energy (ICFCR) IEEE; Piscataway, NJ, USA: 2020. Artificial Intelligence Based Phonocardiogram Proposed for Cardiac Screening of School Children. [Google Scholar]
- 48.Rani S., Masood S. Predicting congenital heart disease using machine learning techniques. J. Discret. Math. Sci. Cryptogr. 2020;23:293–303. doi: 10.1080/09720529.2020.1721890. [DOI] [Google Scholar]
- 49.Bozkurt B., Germanakis I., Stylianou Y. A study of time-frequency features for CNN-based automatic heart sound classification for pathology detection. Comput. Biol. Med. 2018;100:132–143. doi: 10.1016/j.compbiomed.2018.06.026. [DOI] [PubMed] [Google Scholar]
- 50.Liang H., Tsui B.Y., Ni H., Valentim C.C.S., Baxter S.L., Liu G., Cai W., Kermany D.S., Sun X., Chen J., et al. Evaluation and accurate diagnoses of pediatric diseases using artificial intelligence. Nat. Med. 2019;3:433–438. doi: 10.1038/s41591-018-0335-9. [DOI] [PubMed] [Google Scholar]
- 51.Khan K. Hybrid vision transformer framework for congenital heart disease detection using pediatric phonocardiogram signals. 2025. Manuscript in preparation .
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding author.