Electrochemical detector for breath hydrogen determination: measurement of small bowel transit time in normal subjects and patients with the irritable bowel syndrome.

C L Corbett, S Thomas, N W Read, N Hobson, I Bergman, C D Holdsworth
PMCID: PMC1419428  PMID: 7297914

Abstract

A method is described for the measurement of hydrogen in expired air, using an electrochemical detector. The apparatus is simple to use and sensitive. Its application is illustrated by studies of small bowel transit time made by measuring the time between oral ingestion of the unabsorbable carbohydrate lactulose and a rise in the concentration of hydrogen in expired air. In 20 control subjects transit time was 93.0 +/- 6.6 minutes, while in 16 patients with diarrhoea due to the irritable bowel syndrome it was 54.1 +/- 6.3 minutes (P less than 0.001), suggesting an abnormality in small intestinal motility in these patients. Loperamide, a potent antidiarrhoeal agent, increased transit time in 12 of these patients from 56.3 +/- 6.7 to 100.0 +/- 10.2 minutes (P less than 0.001).

Full text

PDF
836

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. BOCKUS H. L., KALSER M. H., ZION D. E. Functional diarrhea: an analysis of the clinical and roentgen manifestations. Gastroenterology. 1956 Dec;31(6):629-46; discussion, 646-8. [PubMed] [Google Scholar]
  2. Bergman I. Electrochemical carbon monoxide sensors based on the metallised membrane electrode. Ann Occup Hyg. 1975 Aug;18(1):53–62. doi: 10.1093/annhyg/18.1.53. [DOI] [PubMed] [Google Scholar]
  3. Bond J. H., Jr, Levitt M. D., Prentiss R. Investigation of small bowel transit time in man utilizing pulmonary hydrogen (H2) measurements. J Lab Clin Med. 1975 Apr;85(4):546–555. [PubMed] [Google Scholar]
  4. Bond J. H., Jr, Levitt M. D. Use of pulmonary hydrogen (H 2 ) measurements to quantitate carbohydrate absorption. Study of partially gastrectomized patients. J Clin Invest. 1972 May;51(5):1219–1225. doi: 10.1172/JCI106916. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Bond J. H., Levitt M. D. Quantitative measurement of lactose absorption. Gastroenterology. 1976 Jun;70(6):1058–1062. [PubMed] [Google Scholar]
  6. Bond J. H., Levitt M. D. Use of breath hydrogen (H2) to quantitate small bowel transit time following partial gastrectomy. J Lab Clin Med. 1977 Jul;90(1):30–36. [PubMed] [Google Scholar]
  7. HOROWITZ L., FARRAR J. T. Intraluminal small intestinal pressures in normal patients and in patients with functional gastrointestinal disorders. Gastroenterology. 1962 Apr;42:455–464. [PubMed] [Google Scholar]
  8. Levitt M. D., Donaldson R. M. Use of respiratory hydrogen (H2) excretion to detect carbohydrate malabsorption. J Lab Clin Med. 1970 Jun;75(6):937–945. [PubMed] [Google Scholar]
  9. Levitt M. D. Production and excretion of hydrogen gas in man. N Engl J Med. 1969 Jul 17;281(3):122–127. doi: 10.1056/NEJM196907172810303. [DOI] [PubMed] [Google Scholar]
  10. Metz G., Gassull M. A., Drasar B. S., Jenkins D. J., Blendis L. M. Breath-hydrogen test for small-intestinal bacterial colonisation. Lancet. 1976 Mar 27;1(7961):668–669. doi: 10.1016/s0140-6736(76)92779-3. [DOI] [PubMed] [Google Scholar]
  11. Metz G., Gassull M. A., Leeds A. R., Blendis L. M., Jenkins D. J. A simple method of measuring breath hydrogen in carbohydrate malabsorption by end-expiratory sampling. Clin Sci Mol Med. 1976 Mar;50(3):237–240. doi: 10.1042/cs0500237. [DOI] [PubMed] [Google Scholar]
  12. Metz G., Jenkins D. J., Newman A., Blends L. M. Breath hydrogen in hyposucrasia. Lancet. 1976 Jan 17;1(7951):119–120. doi: 10.1016/s0140-6736(76)93157-3. [DOI] [PubMed] [Google Scholar]
  13. Metz G., Jenkins D. J., Peters T. J., Newman A., Blendis L. M. Breath hydrogen as a diagnostic method for hypolactasia. Lancet. 1975 May 24;1(7917):1155–1157. doi: 10.1016/s0140-6736(75)93135-9. [DOI] [PubMed] [Google Scholar]
  14. Rhodes J. M., Middleton P., Jewell D. P. The lactulose hydrogen breath test as a diagnostic test for small-bowel bacterial overgrowth. Scand J Gastroenterol. 1979;14(3):333–336. doi: 10.3109/00365527909179892. [DOI] [PubMed] [Google Scholar]

Articles from Gut are provided here courtesy of BMJ Publishing Group

RESOURCES