Abstract
With the object of simplifying the fluorescent protein tracer technique, the following fluorochromes were examined as possible alternatives to fluorescein: aminoeosin, aminorhodamine B, 3-phenyl-7-isocyanatocumarin (Geigy), 5-β-carboxyethylaminoacridine, R 4388 (Geigy), fluolite C (I.C.I.), lissamine flavine FFS (I.C.I.), lissamine rhodamine GS (I.C.I.), and lissamine rhodamine B 200 (I.C.I.) (RB 200). With the exception of RB 200, none was suitable as a protein label largely because of unsatisfactory fluorescence intensity or colour.
RB 200 has proved a successful alternative to fluorescein. The conjugation of dye to protein by a sulphonamido linkage is quick and simple and does not materially affect the physico-chemical or biological properties of the protein. The resulting conjugates are stable, have a brilliant orange fluorescence in ultraviolet light and good contrast with tissue autofluorescence. The contrast is sufficient to permit the use in microscopy of ultraviolet plus blue light with a yellow filter above the object to ensure a black background; fluorescence is greatly enhanced in this way.
When injected intravenously into rats or rabbits, conjugates are distributed in the tissues and eliminated from the plasma in much the same way as proteins labelled with fluorescein or radio-active isotopes. Serum antibody conjugated with RB 200 retains immunological specificity as demonstrated by the staining of the corresponding antigen. Practical use has been made of RB 200 conjugates as plasma tracers and as specific immunological stains: they have been applied alone and in combination with fluorescein conjugates in double tracing experiments.
Full text
PDFImages in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- CHADWICK C. S., McENTEGART M. G., NAIRN R. C. Fluorescent protein tracers; a simple alternative to fluorescein. Lancet. 1958 Feb 22;1(7017):412–414. doi: 10.1016/s0140-6736(58)90721-9. [DOI] [PubMed] [Google Scholar]
- COHEN S., HOLLOWAY R. C., MATTHEWS C., MCFARLANE A. S. Distribution and elimination of 131 I- and 14C-labelled plasma proteins in the rabbit. Biochem J. 1956 Jan;62(1):143–154. doi: 10.1042/bj0620143. [DOI] [PMC free article] [PubMed] [Google Scholar]
- DINEEN J. K., ADA G. L. Rapid extraction with ethyl acetate of free fluorescein derivatives from fluorescein isocyanate-globulin conjugates. Nature. 1957 Dec 7;180(4597):1284–1284. doi: 10.1038/1801284a0. [DOI] [PubMed] [Google Scholar]
- GOLDMAN M., CARVER R. K. Preserving fluorescein isocyanate for simplified preparation of fluorescent antibody. Science. 1957 Oct 25;126(3278):839–840. doi: 10.1126/science.126.3278.839. [DOI] [PubMed] [Google Scholar]
- NAIRN R. C., CHADWICK C. S., McENTEGART M. G. Fluorescent protein tracers in the study of experimental liver damage. J Pathol Bacteriol. 1958 Jul;76(1):143–153. doi: 10.1002/path.1700760115. [DOI] [PubMed] [Google Scholar]
- WEBER G. Polarization of the fluorescence of macromolecules. II. Fluorescent conjugates of ovalbumin and bovine serum albumin. Biochem J. 1952 May;51(2):155–167. doi: 10.1042/bj0510155. [DOI] [PMC free article] [PubMed] [Google Scholar]