Abstract
Concentration of oxygen, methane, and hydrogen were measured in intracolonic gas samples aspirated through the colonoscope at the time of colonoscopy from 46 patients. Of the above patients 20 prepared either with mannitol (n = 10) or with castor oil (n = 10) had the instrument passed to the caecum without air insufflation or suction. After mannitol, mean intracolonic hydrogen concentration (4.07%) was significantly higher (p less than 0.001) than after castor oil (0.51%). Mean oxygen and methane concentrations were approximately similar. Potentially explosive concentrations of hydrogen (greater than 4.1%) and or methane (greater than 5%) were present in 6/10 patients given mannitol and 2/10 patients given castor oil. Nevertheless only one patient from each group had coexisting oxygen concentrations of more than 5% producing thus a combustile mixture. Routine colonoscopy (using air insufflation and suction) was performed in 26 patients prepared with mannitol. Mean intracolonic hydrogen and methane was 0.63% and 0.88% respectively. The highest recorded concentration of hydrogen was 2.6%, and of methane 2.1%, while all patients had oxygen concentrations of more than 5%. It is suggested, therefore, that routine insufflation and suction before colonoscopic electrosurgical polypectomy should result in safe levels of these gases. The remote possibility of pockets of undiluted gas in explosive concentration, however, indicates the use of an inert gas such as carbon dioxide if mannitol preparation is used before electrosurgery.
Full text
PDF



Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Bigard M. A., Gaucher P., Lassalle C. Fatal colonic explosion during colonoscopic polypectomy. Gastroenterology. 1979 Dec;77(6):1307–1310. [PubMed] [Google Scholar]
- Bond J. H., Jr, Engel R. R., Levitt M. D. Factors influencing pulmonary methane excretion in man. An indirect method of studying the in situ metabolism of the methane-producing colonic bacteria. J Exp Med. 1971 Mar 1;133(3):572–588. doi: 10.1084/jem.133.3.572. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bond J. H., Levy M., Levitt M. D. Explosion of hydrogen gas in the colon during proctosigmoidoscopy. Gastrointest Endosc. 1976 Aug;23(1):41–42. doi: 10.1016/s0016-5107(76)73579-x. [DOI] [PubMed] [Google Scholar]
- CARTER H. G. Explosion in the colon during electrodesiccation of polyps. Am J Surg. 1952 Nov;84(5):514–517. doi: 10.1016/0002-9610(52)90078-0. [DOI] [PubMed] [Google Scholar]
- LEVY E. I. Explosions during lower bowel electrosurgery. Am J Surg. 1954 Nov;88(5):754–758. doi: 10.1016/0002-9610(54)90270-6. [DOI] [PubMed] [Google Scholar]
- La Brooy S. J., Avgerinos A., Fendick C. L., Williams C. B., Misiewicz J. J. Potentially explosive colonic concentrations of hydrogen after bowel preparation with mannitol. Lancet. 1981 Mar 21;1(8221):634–636. doi: 10.1016/s0140-6736(81)91553-1. [DOI] [PubMed] [Google Scholar]
- Levitt M. D. Production and excretion of hydrogen gas in man. N Engl J Med. 1969 Jul 17;281(3):122–127. doi: 10.1056/NEJM196907172810303. [DOI] [PubMed] [Google Scholar]
- Raillat A., de Saint-Julien J., Abgrall J. Explosion colique au cours d'une électrocoagulation endoscopique après préparation au mannitol. Gastroenterol Clin Biol. 1982 Mar;6(3):301–302. [PubMed] [Google Scholar]
- Taylor E. W., Bentley S., Youngs D., Keighley M. R. Bowel preparation and the safety of colonoscopic polypectomy. Gastroenterology. 1981 Jul;81(1):1–4. [PubMed] [Google Scholar]