Skip to main content
Journal of the Royal Society of Medicine logoLink to Journal of the Royal Society of Medicine
. 1983 Aug;76(8):667–680. doi: 10.1177/014107688307600809

Twenty-five years of heart valve substitutes: a review.

M M Black, P J Drury, W B Tindale
PMCID: PMC1439283  PMID: 6350585

Full text

PDF
667

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Ashraf M., Bloor C. M. Structural alterations of the porcine heterograft after various durations of implantation. Am J Cardiol. 1978 Jun;41(7):1185–1190. doi: 10.1016/0002-9149(78)90874-3. [DOI] [PubMed] [Google Scholar]
  2. Bellhouse B., Bellhouse F. Fluid mechanics of model normal and stenosed aortic valves. Circ Res. 1969 Dec;25(6):693–704. [PubMed] [Google Scholar]
  3. Broom N. D. Fatigue-induced damage in glutaraldehyde-preserved heart valve tissue. J Thorac Cardiovasc Surg. 1978 Aug;76(2):202–211. [PubMed] [Google Scholar]
  4. Brubakk O., Simonsen S., Källman L., Fredriksen A. Strut fracture in the new Bjørk-Shiley mitral valve prosthesis. Thorac Cardiovasc Surg. 1981 Apr;29(2):108–109. doi: 10.1055/s-2007-1023454. [DOI] [PubMed] [Google Scholar]
  5. CARTWRIGHT R. S., PALICH W. E., FORD W. B., GIACOBINE J. W., ZUBRITZKY S. A., RATAN R. S. Combined replacement of aortic and mitral valves. JAMA. 1962 Apr 7;180:6–10. doi: 10.1001/jama.1962.03050140008002. [DOI] [PubMed] [Google Scholar]
  6. Emery R. W., Anderson R. W., Lindsay W. G., Jorgensen C. R., Wang Y., Nicoloff D. M. Clinical and hemodynamic results with the St. Jude medical aortic valve prosthesis. Surg Forum. 1979;30:235–238. [PubMed] [Google Scholar]
  7. Emery R. W., Nicoloff D. M. St. Jude Medical cardiac valve prosthesis: in vitro studies. J Thorac Cardiovasc Surg. 1979 Aug;78(2):269–276. [PubMed] [Google Scholar]
  8. GIBBON J. H., Jr Application of a mechanical heart and lung apparatus to cardiac surgery. Minn Med. 1954 Mar;37(3):171–passim. [PubMed] [Google Scholar]
  9. Housman L. B., Pitt W. A., Mazur J. H., Litchford B., Gross S. A. Mechanical failure (leaflet disruption) of a porcine aortic heterograft: rare cause of acute aortic insufficiency. J Thorac Cardiovasc Surg. 1978 Aug;76(2):212–213. [PubMed] [Google Scholar]
  10. Ionescu M. I., Ross D. N. Heart-valve replacement with autologous fascia lata. Lancet. 1969 Aug 16;2(7616):335–338. doi: 10.1016/s0140-6736(69)92696-8. [DOI] [PubMed] [Google Scholar]
  11. Kaiser G. A., Hancock W. D., Lukban S. B., Litwak R. S. Clinical use of a new design stented xenograft heart valve prosthesis. Surg Forum. 1969;20:137–138. [PubMed] [Google Scholar]
  12. Martin T. R., Tindale W. B., van Noort R., Black M. M. In vitro heart valve evaluation: fact or fantasy? Trans Am Soc Artif Intern Organs. 1981;27:475–479. [PubMed] [Google Scholar]
  13. McMILLAN I. K. R., DALEY R., MATTHEWS M. B. The movement of aortic and pulmonary valves studied post mortem by colour cinematography. Br Heart J. 1952 Jan;14(1):42–46. doi: 10.1136/hrt.14.1.42. [DOI] [PMC free article] [PubMed] [Google Scholar]
  14. Padula R. T., Cowan G. S., Jr, Camishion R. C. Photographic analysis of the active and passive components of cardiac valvular action. J Thorac Cardiovasc Surg. 1968 Dec;56(6):790–798. [PubMed] [Google Scholar]
  15. ROSS D. N. Homograft replacement of the aortic valve. Lancet. 1962 Sep 8;2(7254):487–487. doi: 10.1016/s0140-6736(62)90345-8. [DOI] [PubMed] [Google Scholar]
  16. Reece I. J., van Noort R., Martin T. R., Black M. M. The physical properties of bovine pericardium: a study of the effects of stretching during chemical treatment in glutaraldehyde. Ann Thorac Surg. 1982 May;33(5):480–485. doi: 10.1016/s0003-4975(10)60789-8. [DOI] [PubMed] [Google Scholar]
  17. Reis R. L., Hancock W. D., Yarbrough J. W., Glancy D. L., Morrow A. G. The flexible stent. A new concept in the fabrication of tissue heart valve prostheses. J Thorac Cardiovasc Surg. 1971 Nov;62(5):683–passim. [PubMed] [Google Scholar]
  18. Reul H., Tesch B., Schoenmackers J., Effert S. Hydromechanical simulation of systemic circulation. Med Biol Eng. 1974 Jul;12(4):431–436. doi: 10.1007/BF02478598. [DOI] [PubMed] [Google Scholar]
  19. Ross D. N. Replacement of aortic and mitral valves with a pulmonary autograft. Lancet. 1967 Nov 4;2(7523):956–958. doi: 10.1016/s0140-6736(67)90794-5. [DOI] [PubMed] [Google Scholar]
  20. Scotten L. N., Walker D. K., Brownlee R. T. Construction and evaluation of a hydromechanical simulation facility for the assessment of mitral valve prostheses. J Med Eng Technol. 1979 Jan;3(1):11–18. doi: 10.3109/03091907909161597. [DOI] [PubMed] [Google Scholar]
  21. Senning A. Aortic valve replacement with fascia lata. Acta Chir Scand Suppl. 1966;356B:17–20. [PubMed] [Google Scholar]
  22. Senning A. Ergebnisse nach Ersatz der Aortenklappe mit autologer Fascia lata. Thoraxchir Vask Chir. 1971 Aug;19(4):304–308. doi: 10.1055/s-0028-1099136. [DOI] [PubMed] [Google Scholar]
  23. Tindale W. B., Black M. M., Martin T. R. In vitro evaluation of prosthetic heart valves: anomalies and limitations. Clin Phys Physiol Meas. 1982 May;3(2):115–130. doi: 10.1088/0143-0815/3/2/002. [DOI] [PubMed] [Google Scholar]
  24. Wain W. H., Greco R., Ignegeri A., Bodnar E., Ross D. N. 15 years experience with 615 homograft and autograft aortic valve replacements. Int J Artif Organs. 1980 May;3(3):169–172. [PubMed] [Google Scholar]

Articles from Journal of the Royal Society of Medicine are provided here courtesy of Royal Society of Medicine Press

RESOURCES