Abstract
A survey in which 939 ventilation tubes of 8 different patterns were inserted and reviewed (up to a maximum of 2 1/4 years) is analysed. Various factors determining the rate of extrusion are discussed. The Sheehy Collar Button tube remained functional for a longer period than any of the other tubes included in the survey.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- Holt J. J., Harner S. G. Effects of large-bore middle ear ventilation tubes. Otolaryngol Head Neck Surg (1979) 1980 Sep-Oct;88(5):581–585. doi: 10.1177/019459988008800511. [DOI] [PubMed] [Google Scholar]
- Pappas J. J. Middle ear ventilation tubes. Laryngoscope. 1974 Jul;84(7):1098–1117. doi: 10.1288/00005537-197407000-00004. [DOI] [PubMed] [Google Scholar]
- Paradise J. L. On tympanostomy tubes: rationale, results, reservations, and recommendations. Pediatrics. 1977 Jul;60(1):86–90. [PubMed] [Google Scholar]
- Shah N. Use of grommets in 'glue' ears. J Laryngol Otol. 1971 Mar;85(3):283–287. doi: 10.1017/s0022215100073448. [DOI] [PubMed] [Google Scholar]