Abstract
The diagnosis of mild hypertension and the treatment of hypertension require accurate measurement of blood pressure. Blood pressure readings are altered by various factors that influence the patient, the techniques used and the accuracy of the sphygmomanometer. The variability of readings can be reduced if informed patients prepare in advance by emptying their bladder and bowel, by avoiding over-the-counter vasoactive drugs the day of measurement and by avoiding exposure to cold, caffeine consumption, smoking and physical exertion within half an hour before measurement. The use of standardized techniques to measure blood pressure will help to avoid large systematic errors. Poor technique can account for differences in readings of more than 15 mm Hg and ultimately misdiagnosis. Most of the recommended procedures are simple and, when routinely incorporated into clinical practice, require little additional time. The equipment must be appropriate and in good condition. Physicians should have a suitable selection of cuff sizes readily available; the use of the correct cuff size is essential to minimize systematic errors in blood pressure measurement. Semiannual calibration of aneroid sphygmomanometers and annual inspection of mercury sphygmomanometers and blood pressure cuffs are recommended. We review the methods recommended for measuring blood pressure and discuss the factors known to produce large differences in blood pressure readings.
Full text
PDF





Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Amery A., Birkenhäger W., Brixko P., Bulpitt C., Clement D., Deruyttere M., De Schaepdryver A., Dollery C., Fagard R., Forette F. Mortality and morbidity results from the European Working Party on High Blood Pressure in the Elderly trial. Lancet. 1985 Jun 15;1(8442):1349–1354. doi: 10.1016/s0140-6736(85)91783-0. [DOI] [PubMed] [Google Scholar]
- Burke M. J., Towers H. M., O'Malley K., Fitzgerald D. J., O'Brien E. T. Sphygmomanometers in hospital and family practice: problems and recommendations. Br Med J (Clin Res Ed) 1982 Aug 14;285(6340):469–471. doi: 10.1136/bmj.285.6340.469. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Curb J. D., Labarthe D. R., Cooper S. P., Cutter G. R., Hawkins C. M. Training and certification of blood pressure observers. Hypertension. 1983 Jul-Aug;5(4):610–614. doi: 10.1161/01.hyp.5.4.610. [DOI] [PubMed] [Google Scholar]
- Geddes L. A., Whistler S. J. The error in indirect blood pressure measurement with the incorrect size of cuff. Am Heart J. 1978 Jul;96(1):4–8. doi: 10.1016/0002-8703(78)90119-9. [DOI] [PubMed] [Google Scholar]
- King G. E. Errors in clinical measurement of blood pressure in obesity. Clin Sci. 1967 Apr;32(2):223–237. [PubMed] [Google Scholar]
- Larochelle P., Bass M. J., Birkett N. J., De Champlain J., Myers M. G. Recommendations from the Consensus Conference on Hypertension in the Elderly. CMAJ. 1986 Oct 1;135(7):741–745. [PMC free article] [PubMed] [Google Scholar]
- Logan A. G. Report of the Canadian Hypertension Society's consensus conference on the management of mild hypertension. Can Med Assoc J. 1984 Nov 1;131(9):1053–1057. [PMC free article] [PubMed] [Google Scholar]
- MITCHELL P. L., PARLIN R. W., BLACKBURN H. EFFECT OF VERTICAL DISPLACEMENT OF THE ARM ON INDIRECT BLOOD-PRESSURE MEASUREMENT. N Engl J Med. 1964 Jul 9;271:72–74. doi: 10.1056/NEJM196407092710204. [DOI] [PubMed] [Google Scholar]
- Mancia G., Parati G. Experience with 24-hour ambulatory blood pressure monitoring in hypertension. Am Heart J. 1988 Oct;116(4):1134–1140. doi: 10.1016/0002-8703(88)90177-9. [DOI] [PubMed] [Google Scholar]
- Messerli F. H., Ventura H. O., Amodeo C. Osler's maneuver and pseudohypertension. N Engl J Med. 1985 Jun 13;312(24):1548–1551. doi: 10.1056/NEJM198506133122405. [DOI] [PubMed] [Google Scholar]
- Myers M. G., Carruthers S. G., Leenen F. H., Haynes R. B. Recommendations from the Canadian Hypertension Society Consensus Conference on the Pharmacologic Treatment of Hypertension. CMAJ. 1989 May 15;140(10):1141–1146. [PMC free article] [PubMed] [Google Scholar]
- O'Hanrahan M., Laher M., O'Boyle C., O'Malley K., O'Brien E. T. Management of high blood pressure in general practice. Ir Med J. 1982 Apr;75(4):102–105. [PubMed] [Google Scholar]
- Petrie J. C., O'Brien E. T., Littler W. A., de Swiet M. Recommendations on blood pressure measurement. Br Med J (Clin Res Ed) 1986 Sep 6;293(6547):611–615. doi: 10.1136/bmj.293.6547.611. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pickering T. G. The influence of daily activity on ambulatory blood pressure. Am Heart J. 1988 Oct;116(4):1141–1145. doi: 10.1016/0002-8703(88)90178-0. [DOI] [PubMed] [Google Scholar]
- Scherwitz L. W., Evans L. A., Hennrikus D. J., Vallbona C. Procedures and discrepancies of blood pressure measurements in two community health centers. Med Care. 1982 Jul;20(7):727–738. doi: 10.1097/00005650-198207000-00008. [DOI] [PubMed] [Google Scholar]
- Silverberg D. S., Shemesh E., Iaina A. The unsupported arm: a cause of falsely raised blood pressure readings. Br Med J. 1977 Nov 19;2(6098):1331–1331. doi: 10.1136/bmj.2.6098.1331. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Webster J., Newnham D., Petrie J. C., Lovell H. G. Influence of arm position on measurement of blood pressure. Br Med J (Clin Res Ed) 1984 May 26;288(6430):1574–1575. doi: 10.1136/bmj.288.6430.1574. [DOI] [PMC free article] [PubMed] [Google Scholar]