Abstract
To evaluate whether the lines occasionally detected on clinical magnetic resonance (MR) images are genuine hippocampal layers, a formalin fixed hippocampal specimen was scanned using T2 weighted sequences at 7 Tesla (voxel dimensions 0.064×0.064×1 mm) and at 1.5 Tesla (voxel dimensions: 0.156×0.156×1 mm) and compared with the results of histological examination. In addition, a healthy volunteer was scanned with a T2 weighted sequence at 1.5 Tesla (voxel dimensions: 0.469×0.469×2 mm). On 7 Tesla images hippocampal layers and the granule cell layer of the dentate were visible. On 1.5 Tesla images of the specimen, the hippocampal layers were again identified, but the granule cell layer of the dentate was not detectable. On 1.5 Tesla images of the hippocampus in vivo, 3 layers could be distinguished in the hippocampus on some slices. These mainly represented the alveus, pyramidal cell layer and stratum radiatum. A dark line consisting of a few pixels possibly represented the dentate gyrus. Our results show that the lines occasionally detected on clinical MR images are likely to be real hippocampal layers. However, the resolution currently used in clinical imaging (typically 0.469×0.469×2 mm or lower) is not sufficient for the detection of all hippocampal layers. For the reliable detection of all hippocampal layers on MR images an increase by a factor of approximately 20 would be necessary.
Keywords: Neuroimaging, hippocampal formation
Full Text
The Full Text of this article is available as a PDF (546.0 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Bronen R. MR of mesial temporal sclerosis: how much is enough? AJNR Am J Neuroradiol. 1998 Jan;19(1):15–18. [PMC free article] [PubMed] [Google Scholar]
- Buckley D. L., Bui J. D., Phillips M. I., Zelles T., Inglis B. A., Plant H. D., Blackband S. J. The effect of ouabain on water diffusion in the rat hippocampal slice measured by high resolution NMR imaging. Magn Reson Med. 1999 Jan;41(1):137–142. doi: 10.1002/(sici)1522-2594(199901)41:1<137::aid-mrm19>3.0.co;2-y. [DOI] [PubMed] [Google Scholar]
- Constable R. T., Gore J. C. The loss of small objects in variable TE imaging: implications for FSE, RARE, and EPI. Magn Reson Med. 1992 Nov;28(1):9–24. doi: 10.1002/mrm.1910280103. [DOI] [PubMed] [Google Scholar]
- Jackson G. D., Berkovic S. F., Duncan J. S., Connelly A. Optimizing the diagnosis of hippocampal sclerosis using MR imaging. AJNR Am J Neuroradiol. 1993 May-Jun;14(3):753–762. [PMC free article] [PubMed] [Google Scholar]
- Jackson G. D., Berkovic S. F., Tress B. M., Kalnins R. M., Fabinyi G. C., Bladin P. F. Hippocampal sclerosis can be reliably detected by magnetic resonance imaging. Neurology. 1990 Dec;40(12):1869–1875. doi: 10.1212/wnl.40.12.1869. [DOI] [PubMed] [Google Scholar]
- Miller M. J., Mark L. P., Ho K. C., Haughton V. M. MR appearance of the internal architecture of Ammon's horn. AJNR Am J Neuroradiol. 1996 Jan;17(1):23–26. [PMC free article] [PubMed] [Google Scholar]
- Pan J. W., Vaughan J. T., Kuzniecky R. I., Pohost G. M., Hetherington H. P. High resolution neuroimaging at 4.1T. Magn Reson Imaging. 1995;13(7):915–921. doi: 10.1016/0730-725x(95)02002-b. [DOI] [PubMed] [Google Scholar]
- Tovi M., Ericsson A. Measurements of T1 and T2 over time in formalin-fixed human whole-brain specimens. Acta Radiol. 1992 Sep;33(5):400–404. [PubMed] [Google Scholar]
- Wolf H. K., Campos M. G., Zentner J., Hufnagel A., Schramm J., Elger C. E., Wiestler O. D. Surgical pathology of temporal lobe epilepsy. Experience with 216 cases. J Neuropathol Exp Neurol. 1993 Sep;52(5):499–506. doi: 10.1097/00005072-199309000-00008. [DOI] [PubMed] [Google Scholar]