Abstract
Two specially shaped sample injection tubes orient flat-shaped mature sperm heads in a flow cytometer. Orientation allows control of a photometric difficulty experienced with some flow cytometers in the measurement of fluorescent and scattered light from sperm and other flat cells. Both relative DNA-stain content and a measure of cell flatness can now be determined simultaneously for each cell at the high rates possible with flow instruments.
Full text
PDF






Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Fulwyler M. J. Hydrodynamic orientation of cells. J Histochem Cytochem. 1977 Jul;25(7):781–783. doi: 10.1177/25.7.330728. [DOI] [PubMed] [Google Scholar]
- Gledhill B. L., Lake S., Steinmetz L. L., Gray J. W., Crawford, Dean P. N., Van Dilla M. A. Flow microfluorometric analysis of sperm DNA content: effect of cell shape on the fluorescence distribution. J Cell Physiol. 1976 Mar;87(3):367–375. doi: 10.1002/jcp.1040870312. [DOI] [PubMed] [Google Scholar]
- Kachel V. Basic principles of electrical sizing of cells and particles and their realization in the new instrument "Metricell". J Histochem Cytochem. 1976 Jan;24(1):211–230. doi: 10.1177/24.1.1254918. [DOI] [PubMed] [Google Scholar]
- Kachel V., Kordwig E., Glossner E. Uniform lateral orientation, caused by flow forces, of flat particles in flow-through systems. J Histochem Cytochem. 1977 Jul;25(7):774–780. doi: 10.1177/25.7.330727. [DOI] [PubMed] [Google Scholar]
- Kay D. B., Wheeless L. L., Jr Experimental findings on gynecologic cell orientation and dynamics for three flow nozzle geometries. J Histochem Cytochem. 1977 Jul;25(7):870–874. doi: 10.1177/25.7.330737. [DOI] [PubMed] [Google Scholar]
- Stovel R. T., Sweet R. G., Herzenberg L. A. A means for orienting flat cells in flow systems. Biophys J. 1978 Jul;23(1):1–5. doi: 10.1016/S0006-3495(78)85427-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Van Dilla M. A., Gledhill B. L., Lake S., Dean P. N., Gray J. W., Kachel V., Barlogie B., Göhde W. Measurement of mammalian sperm deoxyribonucleic acid by flow cytometry. Problems and approaches. J Histochem Cytochem. 1977 Jul;25(7):763–773. doi: 10.1177/25.7.70455. [DOI] [PubMed] [Google Scholar]
- Van Dilla M. A., Trujillo T. T., Mullaney P. F., Coulter J. R. Cell microfluorometry: a method for rapid fluorescence measurement. Science. 1969 Mar 14;163(3872):1213–1214. doi: 10.1126/science.163.3872.1213. [DOI] [PubMed] [Google Scholar]