Red Blood Cell Damage by Shear Stress

L B Leverett, J D Hellums, C P Alfrey, E C Lynch
PMCID: PMC1484094  PMID: 5016112

Abstract

A series of careful studies has been made on blood damage in a rotational viscometer. Specific attention has been focused on the effects of solid surface interaction, centrifugal force, air interface interaction, mixing of sheared and unsheared layers, cell-cell interaction, and viscous heating. The results show that there is a threshold shear stress, 1500 dynes/cm2, above which extensive cell damage is directly due to shear stress, and the various secondary effects listed above are negligible. By analysis of these results and those of prior workers it is shown that the exposure time-shear stress plane is divided into two distinct regimes. In the regime of relatively low stresses and exposure times there is relatively little damage, and the damage is dominated by solid surface interaction effects. In the other regime, at high stresses and exposure times, stress effects alone dominate and very high rates of hemolysis occur. The experimental findings of all prior workers are shown to be consistent when interpreted in this way.

Full text

PDF
257

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bacher R. P., Williams M. C. Hemolysis in capillary flow. J Lab Clin Med. 1970 Sep;76(3):485–496. [PubMed] [Google Scholar]
  2. HANKS G. E., CASSELL M., RAY R. N., CHAPLIN H., Jr Further modification of the benzidine method for measurement of hemoglobin in plasma; definitionn of a new range of normal values. J Lab Clin Med. 1960 Sep;56:486–498. [PubMed] [Google Scholar]
  3. MARSH G. W. INTRAVASCULAR HAEMOLYTIC ANAEMIA AFTER AORTIC-VALVE REPLACEMENT. Lancet. 1964 Nov 7;2(7367):986–988. doi: 10.1016/s0140-6736(64)90931-6. [DOI] [PubMed] [Google Scholar]
  4. SAYED H. M., DACIE J. V., HANDLEY D. A., LEWIS S. M., CLELAND W. P. Haemolytic anaemia of mechanical origin after open heart surgery. Thorax. 1961 Dec;16:356–360. doi: 10.1136/thx.16.4.356. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Williams A. R., Hughes D. E., Nyborg W. L. Hemolysis near a transversely oscillating wire. Science. 1970 Aug 28;169(3948):871–873. doi: 10.1126/science.169.3948.871. [DOI] [PubMed] [Google Scholar]

Articles from Biophysical Journal are provided here courtesy of The Biophysical Society

RESOURCES