Abstract
Convection properties of jackrabbit ears were examined in a wind tunnel and in the field in an attempt to study the possible thermal role of the large ears. This work was part of a study on energy exchange of appendages. Cylindrical copper models of various shapes, aluminum castings of domestic and jackrabbit ears, and an amputated jackrabbit ear were studied in a wind tunnel (a) to define the range for convective heat loss for appendages of various shapes, and (b) to study the effect on convection of model shape and orientation to the wind. Shape, i.e. length and closure, proved important. Orientation to the wind produced no consistent or significant variation in the convection coefficient. The convection coefficients from the ear castings fell within the range generated from the cylindrical models. The convection coefficients for the amputated rabbit ear fell partially within the range. Net thermal radiation loss at midday from the jackrabbit ears was found to be small. Convection from the ears, however, could account for the loss of over 100% of the animal's metabolic heat at an air temperature of 30°C. If air temperature exceeds body temperature, the animal must either store heat or resort to the evaporation of water.