Skip to main content
Environmental Health Perspectives logoLink to Environmental Health Perspectives
. 1995 Feb;103(Suppl 1):21–23. doi: 10.1289/ehp.95103s121

Trace metals speciation by HPLC with plasma source mass spectrometry detection.

F A Byrdy 1, J A Caruso 1
PMCID: PMC1519334  PMID: 7621792

Abstract

The analysis of environmental and biological samples often requires detection at the parts per billion (ppb) level. Plasma source mass spectrometry has potential as a method for the analysis and speciation of trace elements. This is due to the technique's highly selective nature and excellent sensitivity. In comparison to atomic emission detection, detection limits are usually two to three orders of magnitude lower for plasma MS determinations. Interfacing HPLC with plasma MS provides a means of separation that is necessary for speciation. Speciation involves the determination and quantitation of the various chemical forms of a particular element. A host of HPLC-ICP-MS techniques may be used to obtain this information. This brief report will focus on the most recent work in this area, with emphasis on the work done in our laboratory.

Full text

PDF
21

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Crews H. M., Dean J. R., Ebdon L., Massey R. C. Application of high-performance liquid chromatography--inductively coupled plasma mass spectrometry to the investigation of cadmium speciation in pig kidney following cooking and in vitro gastro-intestinal digestion. Analyst. 1989 Aug;114(8):895–899. doi: 10.1039/an9891400895. [DOI] [PubMed] [Google Scholar]
  2. Heitkemper D., Creed J., Caruso J. A. Helium microwave-induced plasma mass spectrometric detection for reversed-phase high-performance liquid chromatography. J Chromatogr Sci. 1990 Apr;28(4):175–181. doi: 10.1093/chromsci/28.4.175. [DOI] [PubMed] [Google Scholar]
  3. Kumar U. T., Dorsey J. G., Caruso J. A., Evans E. H. Speciation of inorganic and organotin compounds in biological samples by liquid chromatography with inductively coupled plasma mass spectrometric detection. J Chromatogr A. 1993 Nov 19;654(2):261–268. doi: 10.1016/0021-9673(93)83369-4. [DOI] [PubMed] [Google Scholar]
  4. Sheppard B. S., Caruso J. A., Heitkemper D. T., Wolnik K. A. Arsenic speciation by ion chromatography with inductively coupled plasma mass spectrometric detection. Analyst. 1992 Jun;117(6):971–975. doi: 10.1039/an9921700971. [DOI] [PubMed] [Google Scholar]
  5. Suyani H., Creed J., Davidson T., Caruso J. Inductively coupled plasma mass spectrometry and atomic emission spectrometry coupled to high-performance liquid chromatography for speciation and detection of organotin compounds. J Chromatogr Sci. 1989 Mar;27(3):139–143. doi: 10.1093/chromsci/27.3.139. [DOI] [PubMed] [Google Scholar]
  6. al-Rashdan A., Heitkemper D., Caruso J. A. Lead speciation by HPLC-ICP-AES and HPLC-ICP-MS. J Chromatogr Sci. 1991 Mar;29(3):98–102. doi: 10.1093/chromsci/29.3.98. [DOI] [PubMed] [Google Scholar]

Articles from Environmental Health Perspectives are provided here courtesy of National Institute of Environmental Health Sciences

RESOURCES