Abstract
Kidney biopsies were obtained in 28 children with glomerular diseases and studied using indirect immunofluorescence and immunoperoxidase for IgG, IgA, IgM, C1q, C3c, C4, fibrinogen and the neoantigens of the terminal C5b-9 complement complex. C5b-9 deposits were detected in glomeruli of 14, in tubules of eight and in vessels of 12 cases. Patients with C5b-9 deposits fared worse than those without such deposits, even with the same histopathological type of glomerulonephritis. The C5b-9 complex suggests an in situ complement activation.
Full text
PDF






Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Adler S., Baker P. J., Pritzl P., Couser W. G. Detection of terminal complement components in experimental immune glomerular injury. Kidney Int. 1984 Dec;26(6):830–837. doi: 10.1038/ki.1984.225. [DOI] [PubMed] [Google Scholar]
- Bhakdi S., Bjerrum O. J., Bhakdi-Lehnen B., Tranum-Jensen J. Complement lysis: evidence for an amphiphilic nature of the terminal membrane C5b-9 complex of human complement. J Immunol. 1978 Dec;121(6):2526–2532. [PubMed] [Google Scholar]
- Bhakdi S., Muhly M. A simple immunoradiometric assay for the terminal SC5b-9 complex of human complement. J Immunol Methods. 1983 Feb 25;57(1-3):283–289. doi: 10.1016/0022-1759(83)90088-1. [DOI] [PubMed] [Google Scholar]
- Bhakdi S., Muhly M., Roth M. Preparation and isolation of specific antibodies to complement components. Methods Enzymol. 1983;93:409–420. doi: 10.1016/s0076-6879(83)93054-9. [DOI] [PubMed] [Google Scholar]
- Bhakdi S., Tranum-Jensen J. Membrane damage by complement. Biochim Biophys Acta. 1983 Aug 11;737(3-4):343–372. doi: 10.1016/0304-4157(83)90006-0. [DOI] [PubMed] [Google Scholar]
- Biesecker G., Katz S., Koffler D. Renal localization of the membrane attack complex in systemic lupus erythematosus nephritis. J Exp Med. 1981 Dec 1;154(6):1779–1794. doi: 10.1084/jem.154.6.1779. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Boesken W. H., Kopf K., Schollmeyer P. Differentiation of proteinuric diseases by discelectrophoretic molecular weight analysis of urinary proteins. Clin Nephrol. 1973 Sep-Oct;1(5):311–318. [PubMed] [Google Scholar]
- Falk R. J., Dalmasso A. P., Kim Y., Tsai C. H., Scheinman J. I., Gewurz H., Michael A. F. Neoantigen of the polymerized ninth component of complement. Characterization of a monoclonal antibody and immunohistochemical localization in renal disease. J Clin Invest. 1983 Aug;72(2):560–573. doi: 10.1172/JCI111004. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kolb W. P., Müller-Eberhard H. J. Neoantigens of the membrane attack complex of human complement. Proc Natl Acad Sci U S A. 1975 May;72(5):1687–1689. doi: 10.1073/pnas.72.5.1687. [DOI] [PMC free article] [PubMed] [Google Scholar]
- LOWRY O. H., ROSEBROUGH N. J., FARR A. L., RANDALL R. J. Protein measurement with the Folin phenol reagent. J Biol Chem. 1951 Nov;193(1):265–275. [PubMed] [Google Scholar]
- Mancini G., Carbonara A. O., Heremans J. F. Immunochemical quantitation of antigens by single radial immunodiffusion. Immunochemistry. 1965 Sep;2(3):235–254. doi: 10.1016/0019-2791(65)90004-2. [DOI] [PubMed] [Google Scholar]
- Müller-Eberhard H. J. Complement. Annu Rev Biochem. 1975;44:697–724. doi: 10.1146/annurev.bi.44.070175.003405. [DOI] [PubMed] [Google Scholar]
- Ríha I., Hasková V., Kaslík J., Maierová M., Stránský J. The use of polyethyleneglycol for immune complex detection in human sera. Mol Immunol. 1979 Jul;16(7):489–493. doi: 10.1016/0161-5890(79)90075-0. [DOI] [PubMed] [Google Scholar]

