Abstract

In 15 children with advanced chronic renal failure, glomerular filtration rate was determined by different methods. Inulin clearance correlated well with the mean of creatinine and urea clearance, and also with 51-chromium edetic acid (EDTA) clearance measured over 24 hours. The absolute values of creatinine clearance and of 51Cr-EDTA clearance measured up to 8 hours were higher than inulin clearance. In advanced renal failure both the 51Cr-EDTA clearance measured over 24 hours, and the mean of creatinine and urea clearance, provide acceptable estimates of true glomerular filtration rate.

Full text

PDF
721

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Broberger U. Determination of glomerular filtration rate in the newborn. Comparison between results obtained by the single injection technique without collection of urine and the standard clearance technique. Acta Paediatr Scand. 1973 Nov;62(6):625–629. doi: 10.1111/j.1651-2227.1973.tb17076.x. [DOI] [PubMed] [Google Scholar]
  2. Chantler C., Barratt T. M. Estimation of glomerular filtration rate from plasma clearance of 51-chromium edetic acid. Arch Dis Child. 1972 Aug;47(254):613–617. doi: 10.1136/adc.47.254.613. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Chantler C., Garnett E. S., Parsons V., Veall N. Glomerular filtration rate measurement in man by the single injection methods using 51Cr-EDTA. Clin Sci. 1969 Aug;37(1):169–180. [PubMed] [Google Scholar]
  4. Counahan R., Chantler C., Ghazali S., Kirkwood B., Rose F., Barratt T. M. Estimation of glomerular filtration rate from plasma creatinine concentration in children. Arch Dis Child. 1976 Nov;51(11):875–878. doi: 10.1136/adc.51.11.875. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Donath A. The simultaneous determination in children of glomerular filtration rate and effective renal plasma flow by the single injection celarance technique. Acta Paediatr Scand. 1971 Sep;60(5):512–520. doi: 10.1111/j.1651-2227.1971.tb06983.x. [DOI] [PubMed] [Google Scholar]
  6. Favre H. Détermination des fonctions rénales par la technique de l'injection unique. Analyse statistique du modéle bicompartimental proposé par Sapirstein. J Urol Nephrol (Paris) 1973 Dec;79(12):1007–1052. [PubMed] [Google Scholar]
  7. Helger R., Rindfrey H., Hilgenfeldt J. Eine Methode zur direkten Bestimmung des Creatinins in Serum und Harn ohne Enteiweissung nach einer modifizierten Jaffé-Methode. Z Klin Chem Klin Biochem. 1974 Jul;12(7):344–349. [PubMed] [Google Scholar]
  8. Kim K. E., Onesti G., Ramirez O., Brest A. N., Swartz C. Creatinine clearance in renal disease. A reappraisal. Br Med J. 1969 Oct 4;4(5674):11–14. doi: 10.1136/bmj.4.5674.11. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Lavender S., Hilton P. J., Jones N. F. The measurement of glomerular filtration-rate in renal disease. Lancet. 1969 Dec 6;2(7632):1216–1218. doi: 10.1016/s0140-6736(69)90752-1. [DOI] [PubMed] [Google Scholar]
  10. Lubowitz H., Slatopolsky E., Shankel S., Rieselbach R. E., Bricker N. S. Glomerular filtration rate. Determination in patients with chronic renal disease. JAMA. 1967 Jan 23;199(4):252–256. doi: 10.1001/jama.199.4.252. [DOI] [PubMed] [Google Scholar]
  11. Maisey M. N., Ogg C. S., Cameron J. S. Measuring glomerular filtration-rate. Lancet. 1969 Apr 5;1(7597):733–733. doi: 10.1016/s0140-6736(69)92685-3. [DOI] [PubMed] [Google Scholar]
  12. Milutinovic J., Cutler R. E., Hoover P., Meijsen B., Scribner B. H. Measurement of residual glomerular filtration rate in the patient receiving repetitive hemodialysis. Kidney Int. 1975 Sep;8(3):185–190. doi: 10.1038/ki.1975.98. [DOI] [PubMed] [Google Scholar]
  13. Skov P. E. Glomerular filtration rate in patients with severe and very severe renal insufficiency. Determined by simultaneous inulin, creatinine and 125 iothalamate clearance. Acta Med Scand. 1970 May;187(5):419–428. doi: 10.1111/j.0954-6820.1970.tb02965.x. [DOI] [PubMed] [Google Scholar]
  14. Vögeli B., Riedwyl H., Donath A., Oetliker O. Comparison of glomerular filtration rate and effective renal plasma flow determinations obtained by a single injection technique and by means of a standard clearance technique in children. Acta Paediatr Scand. 1971 Sep;60(5):528–532. doi: 10.1111/j.1651-2227.1971.tb06985.x. [DOI] [PubMed] [Google Scholar]
  15. Zender R., Vuagnat P., Falbriard A. Etude statistique des causes d'erreur dans la mesure d'une clearance rénale conventionnelle. Clin Chim Acta. 1968 Apr;20(1):85–88. doi: 10.1016/0009-8981(68)90388-4. [DOI] [PubMed] [Google Scholar]