Skip to main content
Environmental Health Perspectives logoLink to Environmental Health Perspectives
. 1984 Mar;54:193–199. doi: 10.1289/ehp.8454193

Renal function in relation to low levels of cadmium exposure in a group of smelter workers.

G Kazantzis, B G Armstrong
PMCID: PMC1568191  PMID: 6734555

Abstract

Blood and urine samples were obtained from 274 smelter workers and urine samples from 48 controls. Cadmium, beta 2-microglobulin, and creatinine were estimated in blood and urine, and total protein in urine. Concentrations of cadmium in urine (mean 2.0 nmole/mmole creatinine) and blood (mean 21.8 nmole/L) observed in the smelter workers confirmed that this group had absorbed more cadmium than the general population, but less than most other occupationally exposed groups studied. Mean beta 2-microglobulin in urine was not significantly different in the smelter workers and the controls. The mean total protein in urine was 20% higher in the smelter workers, a difference which was significant (p congruent to 0.01). There was no consistent picture within the smelter workers of a relationship between history of cadmium exposure and the effect measures of beta 2-microglobulin in urine and blood, total protein in urine, creatinine clearance and relative beta 2-microglobulin clearance. Small but significant positive correlation coefficients were observed between cadmium in urine and beta 2-microglobulin in urine (r = 0.13), total protein in urine (r = 0.23) and beta 2-microglobulin clearance (r = 0.15), although these may be artifactual.

Full text

PDF
193

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bradford M. M. A rapid and sensitive method for the quantitation of microgram quantities of protein utilizing the principle of protein-dye binding. Anal Biochem. 1976 May 7;72:248–254. doi: 10.1016/0003-2697(76)90527-3. [DOI] [PubMed] [Google Scholar]
  2. Cernik A. A., Sayers M. H. Determination of lead in capillary blood using a paper punched disc atomic absorption technique. Application to the supervision of lead workers. Br J Ind Med. 1971 Oct;28(4):392–398. doi: 10.1136/oem.28.4.392. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Evrin P. E., Peterson P. A., Wide L., Berggård I. Radioimmunoassay of 2 -microglobulin in human biological fluids. Scand J Clin Lab Invest. 1971 Dec;28(4):439–443. doi: 10.3109/00365517109095721. [DOI] [PubMed] [Google Scholar]

Articles from Environmental Health Perspectives are provided here courtesy of National Institute of Environmental Health Sciences