Skip to main content
Clinical and Experimental Immunology logoLink to Clinical and Experimental Immunology
. 1969 May;4(5):607–617.

The application of microphotometry to the indirect immunofluorescent antibody technique using the human gastric parietal cell antigen–antibody system

W J Irvine, Moira M W Chan, W G Williamson
PMCID: PMC1579079  PMID: 4892045

Abstract

This paper is an account of our experience in the use of the Leitz microphotometer equipment in the attempt to quantitate the degree of specific fluorescence in the indirect immunofluorescent antibody technique using the human gastric parietal cell antigen–antibody system. The main limitation of the equipment at present is the variability of the HBP 200 W lamp. This fact, together with the biological variation within the tissue section, makes multiple readings necessary. The method is, therefore, time consuming and perhaps mainly applicable to the investigation of standardization of the immunofluorescent technique itself and of the reagents used rather than the quantitation of results obtained in a routine manner using an accepted technique.

Full text

PDF
607

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. COONS A. H., KAPLAN M. H. Localization of antigen in tissue cells; improvements in a method for the detection of antigen by means of fluorescent antibody. J Exp Med. 1950 Jan 1;91(1):1–13. doi: 10.1084/jem.91.1.1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Goldman M. An improved microfluorimeter for measuring brightness of fluorescent antibody reactions. J Histochem Cytochem. 1967 Jan;15(1):38–45. doi: 10.1177/15.1.38. [DOI] [PubMed] [Google Scholar]
  3. IRVINE W. J. GASTRIC ANTIBODIES STUDIED BY FLUORESCENCE MICROSCOPY. Q J Exp Physiol Cogn Med Sci. 1963 Oct;48:427–438. doi: 10.1113/expphysiol.1963.sp001685. [DOI] [PubMed] [Google Scholar]
  4. Mansberg H. P., Kusnetz J. Quantitative fluorescence microscopy: fluorescent antibody automatic scanning techniques. J Histochem Cytochem. 1966 Mar;14(3):260–273. doi: 10.1177/14.3.260. [DOI] [PubMed] [Google Scholar]
  5. Pittman B., Herbert G. A., Cherry W. B., Taylor G. C. The quantitation of nonspecific staining as a guide for improvement of fluorescent antibody conjugates. J Immunol. 1967 Jun;98(6):1196–1203. [PubMed] [Google Scholar]

Articles from Clinical and Experimental Immunology are provided here courtesy of British Society for Immunology

RESOURCES