Skip to main content
Archives of Disease in Childhood logoLink to Archives of Disease in Childhood
. 1989 Oct;64(10 Spec No):1374–1378. doi: 10.1136/adc.64.10_spec_no.1374

Left ventricular output during postnatal circulatory adaptation in healthy infants born at full term.

P Winberg 1, M Jansson 1, L Marions 1, B P Lundell 1
PMCID: PMC1590109  PMID: 2589872

Abstract

Left ventricular output was measured non-invasively at predefined time intervals from less than 15 minutes to 72 hours after birth in 16 infants who had been born at full term. The blood flow velocity in the ascending aorta was measured by a range gated Doppler technique and multiplied by the cross sectional diameter measured by cross sectional and M mode echocardiography. Left ventricular output remained high in the first two hours, 235-243 ml/min/kg, despite a 10% decrease in heart rate. The fall in heart rate was compensated for by a 15% increase in stroke volume. Between 2 and 24 hours there was a significant fall in mean (SD) left ventricular output to 187 (35) ml/min/kg caused mainly by a reduction in stroke volume. The fall in left ventricle output after two hours may reflect an adaptation to the decreased demand on the left ventricle as the ductus constricts.

Full text

PDF
1374

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. ADAMS F. H., LIND J. Physiologic studies on the cardiovascular status of normal newborn infants (with special reference to the ductus arteriosus). Pediatrics. 1957 Mar;19(3):431–437. [PubMed] [Google Scholar]
  2. Alverson D. C., Eldridge M., Dillon T., Yabek S. M., Berman W., Jr Noninvasive pulsed Doppler determination of cardiac output in neonates and children. J Pediatr. 1982 Jul;101(1):46–50. doi: 10.1016/s0022-3476(82)80178-9. [DOI] [PubMed] [Google Scholar]
  3. Clark C., Schultz D. L. Velocity distribution in aortic flow. Cardiovasc Res. 1973 Sep;7(5):601–613. doi: 10.1093/cvr/7.5.601. [DOI] [PubMed] [Google Scholar]
  4. Emmanouilides G. C., Moss A. J., Monset-Couchard M., Marcano B. A., Rzeznic B. Cardiac output in newborn infants. Biol Neonate. 1970;15(34):186–197. doi: 10.1159/000240225. [DOI] [PubMed] [Google Scholar]
  5. Friedman W. F., Kirkpatrick S. E. In situ physiological study of the developing heart. Recent Adv Stud Cardiac Struct Metab. 1975;5:497–504. [PubMed] [Google Scholar]
  6. Friedman W. F. The intrinsic physiologic properties of the developing heart. Prog Cardiovasc Dis. 1972 Jul-Aug;15(1):87–111. doi: 10.1016/0033-0620(72)90006-0. [DOI] [PubMed] [Google Scholar]
  7. Gentile R., Stevenson G., Dooley T., Franklin D., Kawabori I., Pearlman A. Pulsed Doppler echocardiographic determination of time of ductal closure in normal newborn infants. J Pediatr. 1981 Mar;98(3):443–448. doi: 10.1016/s0022-3476(81)80719-6. [DOI] [PubMed] [Google Scholar]
  8. Gessner I., Krovetz L. J., Benson R. W., Prystowsky H., Stenger V., Eitzman D. V. Hemodynamic adaptations in the newborn infant. Pediatrics. 1965 Nov;36(5):752–762. [PubMed] [Google Scholar]
  9. Goldberg S. J., Sahn D. J., Allen H. D., Valdes-Cruz L. M., Hoenecke H., Carnahan Y. Evaluation of pulmonary and systemic blood flow by 2-dimensional Doppler echocardiography using fast Fourier transform spectral analysis. Am J Cardiol. 1982 Dec;50(6):1394–1400. doi: 10.1016/0002-9149(82)90481-7. [DOI] [PubMed] [Google Scholar]
  10. Hiraishi S., Misawa H., Oguchi K., Kadoi N., Saito K., Fujino N., Hojo M., Horiguchi Y., Yashiro K. Two-dimensional Doppler echocardiographic assessment of closure of the ductus arteriosus in normal newborn infants. J Pediatr. 1987 Nov;111(5):755–760. doi: 10.1016/s0022-3476(87)80263-9. [DOI] [PubMed] [Google Scholar]
  11. Hirsimäki H., Kero P., Wanne O., Erkkola R., Makoi Z. Doppler-derived cardiac output in healthy newborn infants in relation to physiological patency of the ductus arteriosus. Pediatr Cardiol. 1988;9(2):79–83. doi: 10.1007/BF02083704. [DOI] [PubMed] [Google Scholar]
  12. Irestedt L., Lagercrantz H., Hjemdahl P., Hägnevik K., Belfrage P. Fetal and maternal plasma catecholamine levels at elective cesarean section under general or epidural anesthesia versus vaginal delivery. Am J Obstet Gynecol. 1982 Apr 15;142(8):1004–1010. doi: 10.1016/0002-9378(82)90783-9. [DOI] [PubMed] [Google Scholar]
  13. Klopfenstein H. S., Rudolph A. M. Postnatal changes in the circulation and responses to volume loading in sheep. Circ Res. 1978 Jun;42(6):839–845. doi: 10.1161/01.res.42.6.839. [DOI] [PubMed] [Google Scholar]
  14. Levy B., Targett R. C., Bardou A., McIlroy M. B. Quantitative ascending aortic Doppler blood velocity in normal human subjects. Cardiovasc Res. 1985 Jul;19(7):383–393. doi: 10.1093/cvr/19.7.383. [DOI] [PubMed] [Google Scholar]
  15. Liu P., Feldman H. S., Covino B. M., Giasi R., Covino B. G. Acute cardiovascular toxicity of intravenous amide local anesthetics in anesthetized ventilated dogs. Anesth Analg. 1982 Apr;61(4):317–322. [PubMed] [Google Scholar]
  16. Lundell B. P., Lindstrom D. P., Arnold T. G. Neonatal cerebral blood flow velocity I. An in vitro validation of the pulsed Doppler technique. Acta Paediatr Scand. 1984 Nov;73(6):810–815. doi: 10.1111/j.1651-2227.1984.tb17780.x. [DOI] [PubMed] [Google Scholar]
  17. Lundell B. P., Wallgren C. G. Assessment of left ventricular adaptation to extrauterine circulation. Acta Paediatr Scand. 1982 Sep;71(5):745–752. doi: 10.1111/j.1651-2227.1982.tb09513.x. [DOI] [PubMed] [Google Scholar]
  18. MOSS A. J., EMMANOUILIDES G., DUFFIE E. R., Jr Closure of the ductus arteriosus in the newborn infant. Pediatrics. 1963 Jul;32:25–30. [PubMed] [Google Scholar]
  19. Mellander M., Sabel K. G., Caidahl K., Solymar L., Eriksson B. Doppler determination of cardiac output in infants and children: comparison with simultaneous thermodilution. Pediatr Cardiol. 1987;8(4):241–246. doi: 10.1007/BF02427536. [DOI] [PubMed] [Google Scholar]
  20. Sahn D. J., DeMaria A., Kisslo J., Weyman A. Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements. Circulation. 1978 Dec;58(6):1072–1083. doi: 10.1161/01.cir.58.6.1072. [DOI] [PubMed] [Google Scholar]
  21. Sonesson S. E., Broberger U. Arterial blood pressure in the very low birthweight neonate. Evaluation of an automatic oscillometric technique. Acta Paediatr Scand. 1987 Mar;76(2):338–341. doi: 10.1111/j.1651-2227.1987.tb10471.x. [DOI] [PubMed] [Google Scholar]
  22. Sonesson S. E., Winberg P., Lundell B. P. Early postnatal changes in intracranial arterial blood flow velocities in term infants. Pediatr Res. 1987 Oct;22(4):461–464. doi: 10.1203/00006450-198710000-00020. [DOI] [PubMed] [Google Scholar]
  23. Walther F. J., Siassi B., King J., Wu P. Y. Normal values of aortic root measurements in neonates. Pediatr Cardiol. 1985;6(2):61–63. doi: 10.1007/BF02282739. [DOI] [PubMed] [Google Scholar]
  24. Walther F. J., Siassi B., Ramadan N. A., Ananda A. K., Wu P. Y. Pulsed Doppler determinations of cardiac output in neonates: normal standards for clinical use. Pediatrics. 1985 Nov;76(5):829–833. [PubMed] [Google Scholar]

Articles from Archives of Disease in Childhood are provided here courtesy of BMJ Publishing Group

RESOURCES