Intermittent ductal patency in healthy newborn infants: demonstration by colour Doppler flow mapping.

M K Lim 1, K Hanretty 1, A B Houston 1, S Lilley 1, E P Murtagh 1
PMCID: PMC1590452  PMID: 1444565

Abstract

Colour Doppler flow mapping was used to determine the time of closure of the arterial duct in 51 healthy newborn infants. Initial time of closure corresponded with previous reports: 20% on the first day, 82% by the second day, 96% by the third day, and 100% by the fourth day. Twenty infants were delivered by caesarean section and followed up for seven days even if the duct had apparently closed; in six intermittent patency was demonstrated with flow in the third, fourth or fifth day, although earlier functional closure had been observed. All were found to be closed on the sixth and seventh days. It is necessary to be aware of the phenomenon of intermittent closure in any study determining or assessing the effect of any intervention on ductal patency.

Full text

PDF
1217

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Drayton M. R., Skidmore R. Ductus arteriosus blood flow during first 48 hours of life. Arch Dis Child. 1987 Oct;62(10):1030–1034. doi: 10.1136/adc.62.10.1030. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Gentile R., Stevenson G., Dooley T., Franklin D., Kawabori I., Pearlman A. Pulsed Doppler echocardiographic determination of time of ductal closure in normal newborn infants. J Pediatr. 1981 Mar;98(3):443–448. doi: 10.1016/s0022-3476(81)80719-6. [DOI] [PubMed] [Google Scholar]
  3. MOSS A. J., EMMANOUILIDES G., DUFFIE E. R., Jr Closure of the ductus arteriosus in the newborn infant. Pediatrics. 1963 Jul;32:25–30. [PubMed] [Google Scholar]
  4. Mandorla S. Il dotto arterioso nel neonato sano, studiato con il Doppler continuo guidato dal Doppler bidimensionale a codice di colore. G Ital Cardiol. 1990 Aug;20(8):705–712. [PubMed] [Google Scholar]
  5. Reller M. D., Ziegler M. L., Rice M. J., Solin R. C., McDonald R. W. Duration of ductal shunting in healthy preterm infants: an echocardiographic color flow Doppler study. J Pediatr. 1988 Mar;112(3):441–446. doi: 10.1016/s0022-3476(88)80333-0. [DOI] [PubMed] [Google Scholar]
  6. Sherman F. S., Sahn D. J. Pediatric Doppler echocardiography 1987: major advances in technology. J Pediatr. 1987 Mar;110(3):333–342. doi: 10.1016/s0022-3476(87)80490-0. [DOI] [PubMed] [Google Scholar]

Articles from Archives of Disease in Childhood are provided here courtesy of BMJ Publishing Group

RESOURCES