Abstract
Grey-scale ultrasonography was used in 212 unselected patients in whom the presence or absence of pancreatic disease was subsequently confirmed by other means. Ultrasonographic criteria were established in the first 92 patients and by reference to previous experience. The remaining 120 patients were studied prospectively. The accuracy and clinical impact of the ultrasonographic diagnosis were judged alongside a standard clinical assessment. Clinical diagnoses were tentative and inaccurate. Ultrasound failed in three cases; otherwise it detected all the 33 patients with chronic pancreatic disease and correctly distinguished cancer from chronic pancreatitis. The ultrasonographic diagnosis of a normal pancreas was always correct, but four false-positive diagnoses were made in patients subsequently judged to have no pancreatic disease. Ultrasonography gave more accurate or more confident and accurate information than the clinical assessment in 57 of the 98 patients studied as problems in diagnosis. With this degree of accuracy ultrasonography should be the first imaging investigation in patients suspected of suffering from pancreatic disease. In our gastrointestinal unit the combination of grey-scale ultrasonography with techniques designed to outline the duct systems (such as endoscopic pancreatography) provides precise diagnosis and documentation of pancreatic disease.
Full text
PDF


Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Aramson N. Cold agglutinins. N Engl J Med. 1977 Sep 29;297(13):727–728. doi: 10.1056/NEJM197709292971316. [DOI] [PubMed] [Google Scholar]
- Baker M. L., Dalrymple G. V. Biological effects of diagnostic ultrasound: a review. Radiology. 1978 Feb;126(2):479–483. doi: 10.1148/126.2.479. [DOI] [PubMed] [Google Scholar]
- Cotton P. B., Denyer M. E., Kreel L., Husband J., Meire H. B., Lees W. Comparative clinical impact of endoscopic pancreatography, grey-scale ultrasonography, and computed tomography (EMI scanning) in pancreatic disease: preliminary report. Gut. 1978 Aug;19(8):679–684. doi: 10.1136/gut.19.8.679. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Cotton P. B. ERCP. Gut. 1977 Apr;18(4):316–341. doi: 10.1136/gut.18.4.316. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Doust B. D., Pearce J. D. Gray-scale ultrasonic properties of the normal and inflamed pancreas. Radiology. 1976 Sep;120(3):653–657. doi: 10.1148/120.3.653. [DOI] [PubMed] [Google Scholar]
- Duncan J. G., Imrie C. W., Blumgart L. H. Ultrasound in the management of acute pancreatitis. Br J Radiol. 1976 Oct;49(586):858–862. doi: 10.1259/0007-1285-49-586-858. [DOI] [PubMed] [Google Scholar]
- Felson B., Freimanis A. K. Echographic study of the pancreas. JAMA. 1975 Apr 21;232(3):287–289. doi: 10.1001/jama.232.3.287. [DOI] [PubMed] [Google Scholar]
- Ferrucci J. T., Jr Radiology of the pancreas, 1976: sonography and ductography. Radiol Clin North Am. 1976 Dec;14(3):543–561. [PubMed] [Google Scholar]
- Fitzgerald P. J., Fortner J. G., Watson R. C., Schwartz M. K., Sherlock P., Benua R. S., Cubilla A. L., Schottenfeld D., Miller D., Winawer S. J. The value of diagnostic aids in detecting pancreas cancer. Cancer. 1978 Mar;41(3):868–879. doi: 10.1002/1097-0142(197803)41:3<868::aid-cncr2820410314>3.0.co;2-0. [DOI] [PubMed] [Google Scholar]
- Freeny P. C., Ball T. J. Rapid diagnosis of pancreatic carcinoma. Radiology. 1978 Jun;127(3):627–633. doi: 10.1148/127.3.627. [DOI] [PubMed] [Google Scholar]
- Haber K., Freimanis A. K., Asher W. M. Demonstration and dimensional analysis of the normal pancreas with gray-scale echography. AJR Am J Roentgenol. 1976 Mar;126(3):624–628. doi: 10.2214/ajr.126.3.624. [DOI] [PubMed] [Google Scholar]
- Holtz U., Falck J., Franken F. H. ERP und Pankreas-Sonographie, eine kritische Gegenüberstellung. Z Gastroenterol. 1977 Oct;15(10):600–600. [PubMed] [Google Scholar]
- Howry D. H. A brief atlas of diagnostic ultrasonic radiologic results. Radiol Clin North Am. 1965 Dec;3(3):433–452. [PubMed] [Google Scholar]
- Husband J. E., Meire H. B., Kreel L. Comparison of ultrasound and computer-assisted tomography in pancreatic diagnosis. Br J Radiol. 1977 Dec;50(600):855–862. doi: 10.1259/0007-1285-50-600-855. [DOI] [PubMed] [Google Scholar]
- Lutz H., Petzoldt R., Hofmann K. P., Rösch W. Ultraschalldiagnostik bei Pankreaserkrankungen. Leistungsfähigkeit der Ultraschalldiagnostik bei Pankreaserkrankungen im Vergleich zur endoskopisch retrograden Pankreasgangdarstellung. Klin Wochenschr. 1975 May 1;53(9):419–424. doi: 10.1007/BF01493366. [DOI] [PubMed] [Google Scholar]
- Taylor K. J., Rosenfield A. T. Visualization of the liver, biliary tree and pancreas. Part III: ultrasound scanning. Clin Gastroenterol. 1978 May;7(2):488–516. [PubMed] [Google Scholar]
- Walls W. J., Gonzalez G., Martin N. L., Templeton A. W. B-scan ultrasound evaluation of the pancreas. Advantages and accuracy compared to other diagnostic techniques. Radiology. 1975 Jan;114(1):127–134. doi: 10.1148/114.1.127. [DOI] [PubMed] [Google Scholar]
- Wood R. A., Moossa A. R., Blackstone M. O., Bowie J., Collins P., Lu C. T. Comparative value of four methods of investigating the pancreas. Surgery. 1976 Oct;80(4):518–522. [PubMed] [Google Scholar]
- Woodward B., Warwick R. How safe is diagnostic sonar? Br J Radiol. 1970 Oct;43(514):719–725. doi: 10.1259/0007-1285-43-514-719. [DOI] [PubMed] [Google Scholar]