Abstract
A new instrument, Eyetone, has been produced for use with a Dextrostix reagent strip for estimating blood sugar levels. It differs from the Dextrostix Reflectance Meter in having only one meter scale, a two-point calibration, and a range of measurement limited to 10-400 mg/100 ml. Results with the manufacturers' original calibration were unsatisfactory, but when recalibrated the performance of the instrument gave a regression equation line close to the ideal. The three Eyetone instruments tested were comparable in their accuracy and functional stability. Packed cell volumes in the blood samples in the range of 30-50% had a negligible effect on the results. The Dextrostix-Eyetone method represents a quick and reliable alternative to conventional laboratory methods for blood sugar estimation. It is especially useful for patients outside hospital.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- BRANDT L., NORDEN A., SCHERSTEN B., TRYDING N. A DIABETES DETECTION CAMPAIGN IN SOUTHERN SWEDEN. RESULTS OF 69,000 EXAMINATIONS. Acta Med Scand. 1964 Nov;176:555–561. doi: 10.1111/j.0954-6820.1964.tb00658.x. [DOI] [PubMed] [Google Scholar]
- COHEN S. L., LEGG S., BIRD R. ABEDSIDE METHOD OF BLOOD-GLUCOSE ESTIMATION. Lancet. 1964 Oct 24;2(7365):883–884. doi: 10.1016/s0140-6736(64)90739-1. [DOI] [PubMed] [Google Scholar]
- HULTMAN E. Rapid specific method for determination of aldosaccharides in body fluids. Nature. 1959 Jan 10;183(4654):108–109. doi: 10.1038/183108a0. [DOI] [PubMed] [Google Scholar]
- Haworth J. C., Dilling L. A., Van Woert M. Blood glucose determination in infants and children. The reflectance meter-enzyme test strip system. Am J Dis Child. 1972 May;123(5):469–471. doi: 10.1001/archpedi.1972.02110110097008. [DOI] [PubMed] [Google Scholar]
- Jarrett R. J., Keen H., Hardwick C. "Instant" blood sugar measurement using Dextrostix and a reflectance meter. Diabetes. 1970 Oct;19(10):724–726. doi: 10.2337/diab.19.10.724. [DOI] [PubMed] [Google Scholar]
- Junker K., Ditzel J. Inaccuracy of test strips with reflectance meter in determination of high blood-sugars. Lancet. 1972 Apr 15;1(7755):815–817. doi: 10.1016/s0140-6736(72)90800-8. [DOI] [PubMed] [Google Scholar]
- RENNIE I. D., KEEN H., SOUTHON A. A RAPID ENZYME-STRIP METHOD FOR ESTIMATING BLOOD-SUGAR. Lancet. 1964 Oct 24;2(7365):884–886. doi: 10.1016/s0140-6736(64)90740-8. [DOI] [PubMed] [Google Scholar]
- Widdowson G. M., Penton J. R. Determination of serum or plasma glucose on the "AutoAnalyzer II" by use of the hexokinase reaction. Clin Chem. 1972 Mar;18(3):299–300. [PubMed] [Google Scholar]
- ZALME E., KNOWLES H. C., Jr A PLEA FOR PLASMA SUGAR. Diabetes. 1965 Mar;14:165–166. doi: 10.2337/diab.14.3.165. [DOI] [PubMed] [Google Scholar]