Abstract
OBJECTIVES. The common operation of fuel-powered resurfacing equipment in enclosed ice skating rinks has the potential for producing high concentrations of carbon monoxide and nitrogen dioxide. Exposures to these gaseous combustion products may adversely affect the health of those inside the rink. Little information is available on pollutant concentrations under normal operating conditions. METHODS. One-week average nitrogen dioxide concentrations in 70 northeastern US rinks were measured with passive samplers during normal winter season conditions. RESULTS. The median nitrogen dioxide level inside rinks was 180 ppb, more than 10 times higher than the median outdoor concentration. One-week average nitrogen dioxide concentrations above 1000 ppb were measured in 10% of the rinks. CONCLUSIONS. Considering that short-term peak concentrations were likely to have reached two to five times the measured 1-week averages, our results suggest that nitrogen dioxide levels were well above short-term air quality guidelines and constitute a public health concern of considerable magnitude.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- Anderson D. E. Problems created for ice arenas by engine exhaust. Am Ind Hyg Assoc J. 1971 Dec;32(12):790–801. doi: 10.1080/0002889718506542. [DOI] [PubMed] [Google Scholar]
- Bauer M. A., Utell M. J., Morrow P. E., Speers D. M., Gibb F. R. Inhalation of 0.30 ppm nitrogen dioxide potentiates exercise-induced bronchospasm in asthmatics. Am Rev Respir Dis. 1986 Dec;134(6):1203–1208. doi: 10.1164/arrd.1986.134.6.1203. [DOI] [PubMed] [Google Scholar]
- Bylin G., Lindvall T., Rehn T., Sundin B. Effects of short-term exposure to ambient nitrogen dioxide concentrations on human bronchial reactivity and lung function. Eur J Respir Dis. 1985 Mar;66(3):205–217. [PubMed] [Google Scholar]
- Centers for Disease Control (CDC) Nitrogen dioxide and carbon monoxide intoxication in an indoor ice arena--Wisconsin, 1992. MMWR Morb Mortal Wkly Rep. 1992 May 29;41(21):383–385. [PubMed] [Google Scholar]
- Dewailly E., Allaire S., Nantel A. Nitrogen dioxide poisoning at a skating rink--Quebec. Can Dis Wkly Rep. 1988 Apr 16;14(15):61–62. [PubMed] [Google Scholar]
- Epler G. R. Silo-filler's disease: a new perspective. Mayo Clin Proc. 1989 Mar;64(3):368–370. doi: 10.1016/s0025-6196(12)65260-4. [DOI] [PubMed] [Google Scholar]
- Folinsbee L. J. Does nitrogen dioxide exposure increase airways responsiveness? Toxicol Ind Health. 1992 Sep-Oct;8(5):273–283. [PubMed] [Google Scholar]
- Ford D. P., Rothman N. Nitrogen dioxide-induced respiratory illness in ice hockey players. JAMA. 1990 Jun 13;263(22):3024–3025. doi: 10.1001/jama.263.22.3024. [DOI] [PubMed] [Google Scholar]
- Frampton M. W., Morrow P. E., Cox C., Gibb F. R., Speers D. M., Utell M. J. Effects of nitrogen dioxide exposure on pulmonary function and airway reactivity in normal humans. Am Rev Respir Dis. 1991 Mar;143(3):522–527. doi: 10.1164/ajrccm/143.3.522. [DOI] [PubMed] [Google Scholar]
- Hasselblad V., Eddy D. M., Kotchmar D. J. Synthesis of environmental evidence: nitrogen dioxide epidemiology studies. J Air Waste Manage Assoc. 1992 May;42(5):662–671. doi: 10.1080/10473289.1992.10467018. [DOI] [PubMed] [Google Scholar]
- Hedberg K., Hedberg C. W., Iber C., White K. E., Osterholm M. T., Jones D. B., Flink J. R., MacDonald K. L. An outbreak of nitrogen dioxide-induced respiratory illness among ice hockey players. JAMA. 1989 Dec 1;262(21):3014–3017. [PubMed] [Google Scholar]
- Linn W. S., Shamoo D. A., Avol E. L., Whynot J. D., Anderson K. R., Venet T. G., Hackney J. D. Dose-response study of asthmatic volunteers exposed to nitrogen dioxide during intermittent exercise. Arch Environ Health. 1986 Sep-Oct;41(5):292–296. doi: 10.1080/00039896.1986.9936699. [DOI] [PubMed] [Google Scholar]
- Lévesque B., Dewailly E., Lavoie R., Prud'Homme D., Allaire S. Carbon monoxide in indoor ice skating rinks: evaluation of absorption by adult hockey players. Am J Public Health. 1990 May;80(5):594–598. doi: 10.2105/ajph.80.5.594. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Miller R. K., Ryan M. C., Bilowus P. Carbon monoxide poisoning in indoor ice skating arenas. Va Med. 1989 Feb;116(2):74–76. [PubMed] [Google Scholar]
- Mohsenin V. Effect of vitamin C on NO2-induced airway hyperresponsiveness in normal subjects. A randomized double-blind experiment. Am Rev Respir Dis. 1987 Dec;136(6):1408–1411. doi: 10.1164/ajrccm/136.6.1408. [DOI] [PubMed] [Google Scholar]
- Morrow P. E. Toxicological data on NOx: an overview. J Toxicol Environ Health. 1984;13(2-3):205–227. doi: 10.1080/15287398409530494. [DOI] [PubMed] [Google Scholar]
- Neas L. M., Dockery D. W., Ware J. H., Spengler J. D., Speizer F. E., Ferris B. G., Jr Association of indoor nitrogen dioxide with respiratory symptoms and pulmonary function in children. Am J Epidemiol. 1991 Jul 15;134(2):204–219. doi: 10.1093/oxfordjournals.aje.a116073. [DOI] [PubMed] [Google Scholar]
- Orehek J., Massari J. P., Gayrard P., Grimaud C., Charpin J. Effect of short-term, low-level nitrogen dioxide exposure on bronchial sensitivity of asthmatic patients. J Clin Invest. 1976 Feb;57(2):301–307. doi: 10.1172/JCI108281. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Petreas M., Liu K. S., Chang B. H., Hayward S. B., Sexton K. A survey of nitrogen dioxide levels measured inside mobile homes. JAPCA. 1988 May;38(5):647–651. doi: 10.1080/08940630.1988.10466405. [DOI] [PubMed] [Google Scholar]
- Sexton K., Liu K. S., Petreas M. X. Formaldehyde concentrations inside private residences: a mail-out approach to indoor air monitoring. J Air Pollut Control Assoc. 1986 Jun;36(6):698–704. doi: 10.1080/00022470.1986.10466104. [DOI] [PubMed] [Google Scholar]
- Spengler J. D., Stone K. R., Lilley F. W. High carbon monoxide levels measured in enclosed skating rinks. J Air Pollut Control Assoc. 1978 Aug;28(8):776–779. doi: 10.1080/00022470.1978.10470658. [DOI] [PubMed] [Google Scholar]