Abstract
The changes in transcutaneous oxygen tension (TcPO2) during 123 observations of 10 care procedures were compared with the intrinsic variability of the TcPO2 at the time of the procedures. Standard deviations of the TcPO2 were measured by planimetry from continuous recording in undisturbed infants during a 10-minute control period immediately before each procedure. The decrement of TcPO2 during the procedure and the change in TcPO2 5 minutes after the procedure had ended were measured. A chest x-ray film had the most striking early hypoxic effect, but all the procedures produced early hypoxia in at least one-quarter of the infants. The significant decreases in oxygenation with particular procedures indicate areas in which changes in techniques might be applied to the benefit of the neonate.
Full text
PDF



Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Fenner A., Müller R., Busse H. G., Junge M., Wolfsdorf J. Transcutaneous determination of arterial oxygen tension. Pediatrics. 1975 Feb;55(2):224–231. [PubMed] [Google Scholar]
- Friis-Hansen B., Lou H. C., Marstrand-Christiansen P., Scheibel E. The influence of apnea and physical activity on arterial blood pressure and transcutaneous oxygen tension in the newborn. Birth Defects Orig Artic Ser. 1979;15(4):461–468. [PubMed] [Google Scholar]
- Hanson N., Okken A. Transcutaneous oxygen tension of newborn infants in different behavioral states. Pediatr Res. 1980 Aug;14(8):911–915. doi: 10.1203/00006450-198008000-00003. [DOI] [PubMed] [Google Scholar]
- Huch R., Huch A., Albani M., Gabriel M., Schulte F. J., Wolf H., Rupprath G., Emmrich P., Stechele U., Duc G. Transcutaneous PO2 monitoring in routine management of infants and children with cardiorespiratory problems. Pediatrics. 1976 May;57(5):681–690. [PubMed] [Google Scholar]
- Huch R., Huch A., Lübbers D. W. Transcutaneous measurement of blood Po2 (tcPo2) -- Method and application in perinatal medicine. J Perinat Med. 1973;1(3):183–191. doi: 10.1515/jpme.1973.1.3.183. [DOI] [PubMed] [Google Scholar]
- Huch R., Lübbers W., Huch A. Reliability of transcutaneous monitoring of arterial PO2 in newborn infants. Arch Dis Child. 1974 Mar;49(3):213–218. doi: 10.1136/adc.49.3.213. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Leraillez J., Iannascoli F., Brioude R., Canet J. Cutaneous PO2: value of analysis of the tracings in neonatal cardiorespiratory pathology. Birth Defects Orig Artic Ser. 1979;15(4):399–406. [PubMed] [Google Scholar]
- Long J. G., Lucey J. F., Philip A. G. Noise and hypoxemia in the intensive care nursery. Pediatrics. 1980 Jan;65(1):143–145. [PubMed] [Google Scholar]
- Long J. G., Philip A. G., Lucey J. F. Excessive handling as a cause of hypoxemia. Pediatrics. 1980 Feb;65(2):203–207. [PubMed] [Google Scholar]
- Martin R. J., Okken A., Rubin D. Changes in arterial oxygen tension during active and quiet sleep in the neonate. Birth Defects Orig Artic Ser. 1979;15(4):493–494. [PubMed] [Google Scholar]
- Monin P., Vert P., Andre M., Vibert M. Transcutaneous PO2 monitoring (tcPO2) in the newborn during apneic spells, convulsions, cardiac catheterizations, and exchange transfusions. Birth Defects Orig Artic Ser. 1979;15(4):469–491. [PubMed] [Google Scholar]
- Peabody J. L., Gregory G. A., Willis M. M., Philip A. G., Lucey J. F. Failure of conventional monitoring to detect apnea resulting in hypoxemia. Birth Defects Orig Artic Ser. 1979;15(4):274–284. [PubMed] [Google Scholar]
- Rawlings D. J., Miller P. A., Engel R. R. The effect of circumcision on transcutaneous PO2 in term infants. Am J Dis Child. 1980 Jul;134(7):676–678. doi: 10.1001/archpedi.1980.02130190044011. [DOI] [PubMed] [Google Scholar]
- Watts J. L., Sinclair J. C. Expression of continuous transcutaneous recordings of PO2. Acta Anaesthesiol Scand Suppl. 1978;68:98–100. doi: 10.1111/j.1399-6576.1978.tb01401.x. [DOI] [PubMed] [Google Scholar]