Abstract
We describe a method of monitoring continuously subarachnoid pressure in the severely asphyxiated newborn by a percutaneously placed catheter. Five infants were studied for a total of 180 hours and although opening pressures were not appreciably raised in any, maximum pressures were above 20 mmHg in four infants and reached a peak of 48 mmHg in one.
Full text
PDF


Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Goitein K. J., Amit Y., Mussaffi H. Intracranial pressure in central nervous system infections and cerebral ischaemia of infancy. Arch Dis Child. 1983 Mar;58(3):184–186. doi: 10.1136/adc.58.3.184. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Horbar J. D., Yeager S., Philip A. G., Lucey J. F. Effect of application force on noninvasive measurements of intracranial pressure. Pediatrics. 1980 Sep;66(3):455–457. [PubMed] [Google Scholar]
- Mayer T., Walker M. L. Emergency intracranial pressure monitoring in pediatrics: management of the acute coma of brain insult. Clin Pediatr (Phila) 1982 Jul;21(7):391–396. doi: 10.1177/000992288202100701. [DOI] [PubMed] [Google Scholar]
- Nelson K. B., Ellenberg J. H. Apgar scores as predictors of chronic neurologic disability. Pediatrics. 1981 Jul;68(1):36–44. [PubMed] [Google Scholar]
- Scott H. Outcome of very severe birth asphyxia. Arch Dis Child. 1976 Sep;51(9):712–716. doi: 10.1136/adc.51.9.712. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Vidyasagar D., Raju T. N. A simple noninvasive technique of measuring intracranial pressure in the newborn. Pediatrics. 1977 Jun;59 (Suppl)(6 Pt 2):957–961. [PubMed] [Google Scholar]