Skip to main content
Applied and Environmental Microbiology logoLink to Applied and Environmental Microbiology
. 1996 Jul;62(7):2236–2243. doi: 10.1128/aem.62.7.2236-2243.1996

Comparison of commercially available kits with standard methods for the detection of coliforms and Escherichia coli in foods.

K Venkateswaran 1, A Murakoshi 1, M Satake 1
PMCID: PMC168004  PMID: 8779561

Abstract

Three commercially available kits that were supplemented with substrates for enzyme reactions were evaluated to determine their abilities to detect coliforms and fecal coliforms in foods. Japanese and U.S. Food and Drug Administration standard methods, as well as two agar plate methods, were compared with the three commercial kits. A total of 50 food samples from various retailers were examined. The levels of detection of coliforms were high with the commercial kits (78 to 98%) compared with the levels of detection with the standard methods (80 to 83%) and the agar plate methods (56 to 83%). Among the kits tested, the Colilert kit had highest level of recovery of coliforms (98%), and the level of recovery of Escherichia coli as determined by beta-glucuronidase activity with the Colilert kit (83%) was comparable to the level of recovery obtained by the U.S. Food and Drug Administration method (87%). Isolation of E. coli on the basis of the beta-glucuronidase enzyme reaction was found to be good. Levine's eosine methylene blue agar, which has been widely used in various laboratories to isolate E. coli was compared with 4-methylumbelliferyl-beta-D-glucuronide (MUG)-supplemented agar for isolation of E. coli. Only 47% of the E. coli was detected when eosine methylene blue agar was used; however, when violet red bile (VRB)-MUG agar was used, the E. coli detection rate was twice as high. Of the 200 E. coli strains isolated, only 2 were found to be MUG negative, and the gene responsible for beta-glucuronidase activity (uidA gene) was detected by the PCR method in these 2 strains. Of the 90 false-positive strains isolated that exhibited various E. coli characteristic features, only 2 non-E.coli strains hydrolyzed MUG and produced fluorescent substrate in VRB-MUG agar. However, the PCR did not amplify uidA gene products in these VRB-MUG fluorescence-positive strains.

Full Text

The Full Text of this article is available as a PDF (336.0 KB).

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bej A. K., DiCesare J. L., Haff L., Atlas R. M. Detection of Escherichia coli and Shigella spp. in water by using the polymerase chain reaction and gene probes for uid. Appl Environ Microbiol. 1991 Apr;57(4):1013–1017. doi: 10.1128/aem.57.4.1013-1017.1991. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Brenner K. P., Rankin C. C., Roybal Y. R., Stelma G. N., Jr, Scarpino P. V., Dufour A. P. New medium for the simultaneous detection of total coliforms and Escherichia coli in water. Appl Environ Microbiol. 1993 Nov;59(11):3534–3544. doi: 10.1128/aem.59.11.3534-3544.1993. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Chang G. W., Brill J., Lum R. Proportion of beta-D-glucuronidase-negative Escherichia coli in human fecal samples. Appl Environ Microbiol. 1989 Feb;55(2):335–339. doi: 10.1128/aem.55.2.335-339.1989. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Clark D. L., Milner B. B., Stewart M. H., Wolfe R. L., Olson B. H. Comparative study of commercial 4-methylumbelliferyl-beta-D-glucuronide preparations with the Standard Methods membrane filtration fecal coliform test for the detection of Escherichia coli in water samples. Appl Environ Microbiol. 1991 May;57(5):1528–1534. doi: 10.1128/aem.57.5.1528-1534.1991. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Clark J. A., el-Shaarawi A. H. Evaluation of commercial presence-absence test kits for detection of total coliforms, Escherichia coli, and other indicator bacteria. Appl Environ Microbiol. 1993 Feb;59(2):380–388. doi: 10.1128/aem.59.2.380-388.1993. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Edberg S. C., Allen M. J., Smith D. B. National field evaluation of a defined substrate method for the simultaneous detection of total coliforms and Escherichia coli from drinking water: comparison with presence-absence techniques. Appl Environ Microbiol. 1989 Apr;55(4):1003–1008. doi: 10.1128/aem.55.4.1003-1008.1989. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Feng P. C., Hartman P. A. Fluorogenic assays for immediate confirmation of Escherichia coli. Appl Environ Microbiol. 1982 Jun;43(6):1320–1329. doi: 10.1128/aem.43.6.1320-1329.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Feng P., Lampel K. A. Genetic analysis of uidA expression in enterohaemorrhagic Escherichia coli serotype O157:H7. Microbiology. 1994 Aug;140(Pt 8):2101–2107. doi: 10.1099/13500872-140-8-2101. [DOI] [PubMed] [Google Scholar]
  9. Feng P., Lum R., Chang G. W. Identification of uidA gene sequences in beta-D-glucuronidase-negative Escherichia coli. Appl Environ Microbiol. 1991 Jan;57(1):320–323. doi: 10.1128/aem.57.1.320-323.1991. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Hahn G., Wittrock E. Comparison of chromogenic and fluorogenic substances for differentiation of coliforms and Escherichia coli in soft cheese. Acta Microbiol Hung. 1991;38(3-4):265–271. [PubMed] [Google Scholar]
  11. Le Minor L. Tetrathionate-reductase, beta glucuronidase et test a l'ONPG chez des cultures du genre Salmonella. Zentralbl Bakteriol Orig A. 1979 Apr;243(2-3):321–325. [PubMed] [Google Scholar]
  12. Manafi M., Kneifel W., Bascomb S. Fluorogenic and chromogenic substrates used in bacterial diagnostics. Microbiol Rev. 1991 Sep;55(3):335–348. doi: 10.1128/mr.55.3.335-348.1991. [DOI] [PMC free article] [PubMed] [Google Scholar]
  13. Moberg L. J. Fluorogenic assay for rapid detection of Escherichia coli in food. Appl Environ Microbiol. 1985 Dec;50(6):1383–1387. doi: 10.1128/aem.50.6.1383-1387.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
  14. Moberg L. J., Wagner M. K., Kellen L. A. Fluorogenic assay for rapid detection of Escherichia coli in chilled and frozen foods: collaborative study. J Assoc Off Anal Chem. 1988 May-Jun;71(3):589–602. [PubMed] [Google Scholar]
  15. Olson B. H., Clark D. L., Milner B. B., Stewart M. H., Wolfe R. L. Total coliform detection in drinking water: comparison of membrane filtration with Colilert and Coliquik. Appl Environ Microbiol. 1991 May;57(5):1535–1539. doi: 10.1128/aem.57.5.1535-1539.1991. [DOI] [PMC free article] [PubMed] [Google Scholar]
  16. Palmer C. J., Tsai Y. L., Lang A. L., Sangermano L. R. Evaluation of colilert-marine water for detection of total coliforms and Escherichia coli in the marine environment. Appl Environ Microbiol. 1993 Mar;59(3):786–790. doi: 10.1128/aem.59.3.786-790.1993. [DOI] [PMC free article] [PubMed] [Google Scholar]
  17. Park S. J., Lee E. J., Lee D. H., Lee S. H., Kim S. J. Spectrofluorometric assay for rapid detection of total and fecal coliforms from surface water. Appl Environ Microbiol. 1995 May;61(5):2027–2029. doi: 10.1128/aem.61.5.2027-2029.1995. [DOI] [PMC free article] [PubMed] [Google Scholar]
  18. Poelma P. L., Wilson C. R., Andrews W. H. Rapid fluorogenic enumeration of Escherichia coli in selected, naturally contaminated high moisture foods. J Assoc Off Anal Chem. 1987 Nov-Dec;70(6):991–993. [PubMed] [Google Scholar]
  19. Rice E. W., Allen M. J., Brenner D. J., Edberg S. C. Assay for beta-glucuronidase in species of the genus Escherichia and its applications for drinking-water analysis. Appl Environ Microbiol. 1991 Feb;57(2):592–593. doi: 10.1128/aem.57.2.592-593.1991. [DOI] [PMC free article] [PubMed] [Google Scholar]
  20. Rice E. W., Allen M. J., Edberg S. C. Efficacy of beta-glucuronidase assay for identification of Escherichia coli by the defined-substrate technology. Appl Environ Microbiol. 1990 May;56(5):1203–1205. doi: 10.1128/aem.56.5.1203-1205.1990. [DOI] [PMC free article] [PubMed] [Google Scholar]
  21. Robison B. J. Evaluation of a fluorogenic assay for detection of Escherichia coli in foods. Appl Environ Microbiol. 1984 Aug;48(2):285–288. doi: 10.1128/aem.48.2.285-288.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  22. Tsai Y. L., Palmer C. J., Sangermano L. R. Detection of Escherichia coli in sewage and sludge by polymerase chain reaction. Appl Environ Microbiol. 1993 Feb;59(2):353–357. doi: 10.1128/aem.59.2.353-357.1993. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Applied and Environmental Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES