Abstract
OBJECTIVES. Reported cases of building-related asthma and hypersensitivity pneumonitis among workers in a Denver office building prompted an epidemiologic investigation. METHODS. A cross-sectional, self-administered survey of employees in the office building of the reported cases was compared with that of employees in a comparison building. RESULTS. A significant excess of respiratory disease existed among 512 Denver workers (case building) compared with 281 office workers in a suburban agency (control building). Denver employees had a higher prevalence of respiratory symptoms, and the prevalence of physician-diagnosed asthma with onset or exacerbation since building occupancy was 4.9 times greater for Denver employees than for suburban employees. Asthma was not associated with any particular ventilation system in the building. Water incursion from a below-grade wall may have contributed to the problem, but the etiology is unknown. CONCLUSIONS. This investigation provided evidence of office building-related asthma. Individual cases may be sentinel events for other cases of work-related asthma or hypersensitivity pneumonitis and may indicate a need for public health investigation of remediable causes.
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- Baker E. L. Sentinel Event Notification System for Occupational Risks (SENSOR): the concept. Am J Public Health. 1989 Dec;79 (Suppl):18–20. doi: 10.2105/ajph.79.suppl.18. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bernstein R. S., Sorenson W. G., Garabrant D., Reaux C., Treitman R. D. Exposures to respirable, airborne Penicillium from a contaminated ventilation system: clinical, environmental and epidemiological aspects. Am Ind Hyg Assoc J. 1983 Mar;44(3):161–169. doi: 10.1080/15298668391404581. [DOI] [PubMed] [Google Scholar]
- Burge P. S., Finnegan M., Horsfield N., Emery D., Austwick P., Davies P. S., Pickering C. A. Occupational asthma in a factory with a contaminated humidifier. Thorax. 1985 Apr;40(4):248–254. doi: 10.1136/thx.40.4.248. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Chan-Yeung M., Lam S. Occupational asthma. Am Rev Respir Dis. 1986 Apr;133(4):686–703. doi: 10.1164/arrd.1986.133.4.686. [DOI] [PubMed] [Google Scholar]
- Coleman A., Colby T. V. Histologic diagnosis of extrinsic allergic alveolitis. Am J Surg Pathol. 1988 Jul;12(7):514–518. doi: 10.1097/00000478-198807000-00002. [DOI] [PubMed] [Google Scholar]
- Finnegan M. J., Pickering C. A. Building related illness. Clin Allergy. 1986 Sep;16(5):389–405. doi: 10.1111/j.1365-2222.1986.tb01974.x. [DOI] [PubMed] [Google Scholar]
- Hodgson M. J., Morey P. R., Attfield M., Fink J. N., Rhodes W. W., Sorenson W., Visvesvara G. S. Pulmonary disease associated with cafeteria flooding. Arch Environ Health. 1985 Mar-Apr;40(2):96–101. doi: 10.1080/00039896.1985.10545897. [DOI] [PubMed] [Google Scholar]
- Matte T. D., Baker E. L., Honchar P. A. The selection and definition of targeted work-related conditions for surveillance under SENSOR. Am J Public Health. 1989 Dec;79 (Suppl):21–25. doi: 10.2105/ajph.79.suppl.21. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Mendell M. J., Smith A. H. Consistent pattern of elevated symptoms in air-conditioned office buildings: a reanalysis of epidemiologic studies. Am J Public Health. 1990 Oct;80(10):1193–1199. doi: 10.2105/ajph.80.10.1193. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Reyes C. N., Wenzel F. J., Lawton B. R., Emanuel D. A. The pulmonary pathology of farmer's lung disease. Chest. 1982 Feb;81(2):142–146. doi: 10.1378/chest.81.2.142. [DOI] [PubMed] [Google Scholar]
- Robertson A. S., Burge P. S. Building sickness. Practitioner. 1985 Jun;229(1404):531–534. [PubMed] [Google Scholar]
- Rutstein D. D., Mullan R. J., Frazier T. M., Halperin W. E., Melius J. M., Sestito J. P. Sentinel Health Events (occupational): a basis for physician recognition and public health surveillance. Am J Public Health. 1983 Sep;73(9):1054–1062. doi: 10.2105/ajph.73.9.1054. [DOI] [PMC free article] [PubMed] [Google Scholar]