Abstract
A human reference serum pool, lot 89-S, has been developed for use in quantitating concentrations of antibody to Streptococcus pneumoniae. Weight-based units have been assigned to antibodies to 11 pneumococcal polysaccharide (PnPs) serotypes (1, 3, 4, 5, 6B, 7F, 9V, 14, 18C, 19F, and 23F) by using enzyme-linked immunosorbent assay methodology and a human standard reference serum, USNRP IS 1644. The experimentally derived assignments for anti-PnPs antibodies of the immunoglobulin G (IgG), IgM, and IgA isotypes in lot 89-S correlate well to the separately determined immunoglobulin assignment. These assignments for this antipneumococcal standard serum were used to quantitate IgG, IgM, and IgA isotype levels and the total immunoglobulin level in pediatric samples from a pneumococcal conjugate vaccine trial. The data indicate that these assignments may be used to assess levels of antibody to PnPs serotypes in human serum.
Full Text
The Full Text of this article is available as a PDF (228.7 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Griswold W. R., Chalquest R. R. Theoretical analysis of the accuracy of calibrated immunoassays for measuring antibody concentration. Mol Immunol. 1991 Jul;28(7):727–732. doi: 10.1016/0161-5890(91)90115-z. [DOI] [PubMed] [Google Scholar]
- Konradsen H. B., Sørensen U. B., Henrichsen J. A modified enzyme-linked immunosorbent assay for measuring type-specific anti-pneumococcal capsular polysaccharide antibodies. J Immunol Methods. 1993 Aug 26;164(1):13–20. doi: 10.1016/0022-1759(93)90270-h. [DOI] [PubMed] [Google Scholar]
- Koskela M., Leinonen M. Comparison of ELISA and RIA for measurement of pneumococcal antibodies before and after vaccination with 14-valent pneumococcal capsular polysaccharide vaccine. J Clin Pathol. 1981 Jan;34(1):93–98. doi: 10.1136/jcp.34.1.93. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Koskela M. Serum antibodies to pneumococcal C polysaccharide in children: response to acute pneumococcal otitis media or to vaccination. Pediatr Infect Dis J. 1987 Jun;6(6):519–526. doi: 10.1097/00006454-198706000-00006. [DOI] [PubMed] [Google Scholar]
- LIU T. Y., GOTSCHLICH E. C. The chemical composition of pneumococcal C-polysaccharide. J Biol Chem. 1963 Jun;238:1928–1934. [PubMed] [Google Scholar]
- Musher D. M., Luchi M. J., Watson D. A., Hamilton R., Baughn R. E. Pneumococcal polysaccharide vaccine in young adults and older bronchitics: determination of IgG responses by ELISA and the effect of adsorption of serum with non-type-specific cell wall polysaccharide. J Infect Dis. 1990 Apr;161(4):728–735. doi: 10.1093/infdis/161.4.728. [DOI] [PubMed] [Google Scholar]
- Pedersen F. K., Henrichsen J., Sørensen U. S., Nielsen J. L. Anti-C-carbohydrate antibodies after pneumococcal vaccination. Acta Pathol Microbiol Immunol Scand C. 1982 Dec;90(6):353–355. doi: 10.1111/j.1699-0463.1982.tb01462.x. [DOI] [PubMed] [Google Scholar]
- Pruslin F. H., To S. E., Winston R., Rodman T. C. Caveats and suggestions for the ELISA. J Immunol Methods. 1991 Mar 1;137(1):27–35. doi: 10.1016/0022-1759(91)90390-2. [DOI] [PubMed] [Google Scholar]
- Reimer C. B., Smith S. J., Wells T. W., Nakamura R. M., Keitges P. W., Ritchie R. F., Williams G. W., Hanson D. J., Dorsey D. B. Collaborative calibration of the U. S. National and the College of American Pathologists reference preparations for specific serum proteins. Am J Clin Pathol. 1982 Jan;77(1):12–19. doi: 10.1093/ajcp/77.1.12. [DOI] [PubMed] [Google Scholar]
- Robbins J. B. Vaccines for the prevention of encapsulated bacterial diseases: current status, problems and prospects for the future. Immunochemistry. 1978 Nov;15(10-11):839–854. doi: 10.1016/0161-5890(78)90117-7. [DOI] [PubMed] [Google Scholar]
- Rudolph K. M., Parkinson A. J. Measurement of pneumococcal capsular polysaccharide serotype-specific immunoglobulin G in human serum, a method for assigning weight-based units to proposed reference sera. Clin Diagn Lab Immunol. 1994 Sep;1(5):526–530. doi: 10.1128/cdli.1.5.526-530.1994. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Siber G. R., Priehs C., Madore D. V. Standardization of antibody assays for measuring the response to pneumococcal infection and immunization. Pediatr Infect Dis J. 1989 Jan;8(1 Suppl):S84–S91. [PubMed] [Google Scholar]
- Sørensen U. B., Henrichsen J. C-polysaccharide in a pneumococcal vaccine. Acta Pathol Microbiol Immunol Scand C. 1984 Dec;92(6):351–356. doi: 10.1111/j.1699-0463.1984.tb00099.x. [DOI] [PubMed] [Google Scholar]
- Zollinger W. D., Boslego J. W. A general approach to standardization of the solid-phase radioimmunoassay for quantitation of class-specific antibodies. J Immunol Methods. 1981;46(2):129–140. doi: 10.1016/0022-1759(81)90130-7. [DOI] [PubMed] [Google Scholar]
- Zollinger W. D., Dalrymple J. M., Artenstein M. S. Analysis of parameters affecting the solid phase radioimmunoassay quantitation of antibody to meningococcal antigens. J Immunol. 1976 Nov;117(5 PT2):1788–1798. [PubMed] [Google Scholar]