Skip to main content
Applied and Environmental Microbiology logoLink to Applied and Environmental Microbiology
. 1977 May;33(5):1229–1232. doi: 10.1128/aem.33.5.1229-1232.1977

Comparison of two direct-count techniques for enumerating aquatic bacteria.

W B Bowden
PMCID: PMC170857  PMID: 327933

Abstract

Planktonic bacteria from an estuary were concentrated on membrane filters and counted with both a scanning electron microscope and an epi-illuminated fluorescent microscope. Counts on 0.2 micron Nuclepore filters (polycarbonate) were significantly higher (P less than 0.001) than counts on 0.2-micron Sartorius filters (cellulose). In contrast, there was not a statistically significant difference between the two techniques when Nuclepore filters were used (0.5 less than P less than 0.9). The average cell volume from this study area was 0.047 micron3. The estimated number of bacteria ranged from 10(6) to 10(7) bacteria per ml, representing from 4 to 40 mg of C per m3.

Full text

PDF
1229

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Fleischer R. L., Price P. B., Symes E. M. Novel Filter for Biological Materials. Science. 1964 Jan 17;143(3603):249–250. doi: 10.1126/science.143.3603.249. [DOI] [PubMed] [Google Scholar]
  2. Gray T. R. Stereoscan electron microscopy of soil microorganisms. Science. 1967 Mar 31;155(3770):1668–1670. doi: 10.1126/science.155.3770.1668. [DOI] [PubMed] [Google Scholar]
  3. Hagen C. A., Hawrylewicz E. J., Anderson B. T., Tolkacz V. K., Cephus M. L. Use of the scanning electron microscope for viewing bacteria in soil. Appl Microbiol. 1968 Jun;16(6):932–934. doi: 10.1128/am.16.6.932-934.1968. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Hobbie J. E., Daley R. J., Jasper S. Use of nuclepore filters for counting bacteria by fluorescence microscopy. Appl Environ Microbiol. 1977 May;33(5):1225–1228. doi: 10.1128/aem.33.5.1225-1228.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Kurtzman C. P., Baker F. L., Smiley M. J. Specimen holder to critical-point dry microorganisms for scanning electron microscopy. Appl Microbiol. 1974 Oct;28(4):708–712. doi: 10.1128/am.28.4.708-712.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Todd R. L., Kerr T. J. Scanning electron microscopy of microbial cells on membrane filters. Appl Microbiol. 1972 Jun;23(6):1160–1162. doi: 10.1128/am.23.6.1160-1162.1972. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Watson S. W., Novitsky T. J., Quinby H. L., Valois F. W. Determination of bacterial number and biomass in the marine environment. Appl Environ Microbiol. 1977 Apr;33(4):940–946. doi: 10.1128/aem.33.4.940-946.1977. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Applied and Environmental Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES