Skip to main content
Applied and Environmental Microbiology logoLink to Applied and Environmental Microbiology
. 1977 Jun;33(6):1259–1264. doi: 10.1128/aem.33.6.1259-1264.1977

Two-temperature membrane filter method for enumerating fecal coliform bacteria from chlorinated effluents.

B L Green, E M Clausen, W Litsky
PMCID: PMC170867  PMID: 327935

Abstract

Reports indicate that the standard membrane filter (MF) technique for recovery of fecal coliform bacteria from chlorinated sewage effluents is less effective than the multiple-tube (or most-probable-number [MPN]) procedure. A modified MF method was developed that requires a preincubation period of 5 h at 35 degrees C followed by 18+/-1 h at 44.5 degrees C. This procedure was evaluated by using both laboratory- and plant-chlorinated primary and secondary effluents. Results obtained by the modified MF method compared favorably with those of the MPN technique for the enumeration of fecal coliforms from chlorinated effluent. Agreement between these two methods was greatest with samples from secondary treatment plants. The average recovery of fecal coliforms by the standard MF procedure was only 14% that of the MPN method, whereas with the modified technique recovery was increased to 68% of the MPN counts. Enhanced recovery resulting from a simple modification in the incubation schedule makes the MF method a valuable adjunct for enumerating fecal coliforms from chlorinated effluents.

Full text

PDF
1259

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Braswell J. R., Hoadley A. W. Recovery of Escherichia coli from chlorinated secondary sewage. Appl Microbiol. 1974 Aug;28(2):328–329. doi: 10.1128/am.28.2.328-329.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Lin S. Evaluation of coliform tests for chlorinated secondary effluents. J Water Pollut Control Fed. 1973 Mar;45(1):498–506. [PubMed] [Google Scholar]
  3. McCARTHY J. A., THOMAS H. A., Jr, DELANEY J. E. Evaluation of the reliability of coliform density tests. Am J Public Health Nations Health. 1958 Dec;48(12):1628–1635. doi: 10.2105/ajph.48.12.1628. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Rose R. E., Geldreich E. E., Litsky W. Improved membrane filter method for fecal coliform analysis. Appl Microbiol. 1975 Apr;29(4):532–536. doi: 10.1128/am.29.4.532-536.1975. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Applied and Environmental Microbiology are provided here courtesy of American Society for Microbiology (ASM)