Skip to main content
Archives of Disease in Childhood logoLink to Archives of Disease in Childhood
. 2004 Dec;89(12):1168–1173. doi: 10.1136/adc.2003.046532

Interventional cardiac catheterisation in congenital heart disease

R Andrews 1, R Tulloh 1
PMCID: PMC1719759  PMID: 15557059

Full Text

The Full Text of this article is available as a PDF (231.4 KB).

Figure 1.

Figure 1

 Angiographic pictures of stent insertion for re-coarctation following subclavian flap repair; (A) pre-procedure, (B) stent insertion, (C) stent expansion by inflation of internal balloon, (D) final result.

Figure 2.

Figure 2

 Angiographic pictures of radiofrequency perforation for pulmonary atresia; (A) catheter against imperforate valve (lateral projection), (B) radiofrequency wire across valve, (C) balloon dilation of valve perforation, (D) antegrade flow established.

Figure 3.

Figure 3

 Devices for duct occlusion: a pair of Amplatzer Ductocclude devices, and a pair of Cook MReye coils.

Figure 4.

Figure 4

 An Amplatzer Septal Occluder for closure of atrial septal defects.

Figure 5.

Figure 5

 A Helex device for closure of atrial septal defects.

Figure 6.

Figure 6

 Angiographic pictures of device occlusion of a VSD; (A) + (B) balloon sizing of the defect, (C) + (D) deployment of the device.

Figure 7.

Figure 7

 A pair of implantable pulmonary valved stents. The fine tissue of a closed valve is shown in the device on the left.

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Acar P., Saliba Z., Bonhoeffer P., Aggoun Y., Bonnet D., Sidi D., Kachaner J. Influence of atrial septal defect anatomy in patient selection and assessment of closure with the Cardioseal device; a three-dimensional transoesophageal echocardiographic reconstruction. Eur Heart J. 2000 Apr;21(7):573–581. doi: 10.1053/euhj.1999.1855. [DOI] [PubMed] [Google Scholar]
  2. Agnoletti Gabriella, Piechaud Jean François, Bonhoeffer Philipp, Aggoun Yacine, Abdel-Massih Tony, Boudjemline Younes, Le Bihan Christine, Bonnet Damien, Sidi Daniel. Perforation of the atretic pulmonary valve. Long-term follow-up. J Am Coll Cardiol. 2003 Apr 16;41(8):1399–1403. doi: 10.1016/s0735-1097(03)00167-0. [DOI] [PubMed] [Google Scholar]
  3. Andrews R. E., Tulloh R. M. R., Rigby M. L. Percutaneous retrieval of central venous catheter fragments. Arch Dis Child. 2002 Aug;87(2):149–150. doi: 10.1136/adc.87.2.149. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Bass John L., Kalra G. S., Arora Ramesh, Masura Jozef, Gavora Pavlo, Thanopoulos Basil D., Torres William, Sievert Horst, Carminati Mario, Fischer Gunther. Initial human experience with the Amplatzer perimembranous ventricular septal occluder device. Catheter Cardiovasc Interv. 2003 Feb;58(2):238–245. doi: 10.1002/ccd.10406. [DOI] [PubMed] [Google Scholar]
  5. Beekman R. H., 3rd, Shim D., Lloyd T. R. Embolization therapy in pediatric cardiology. J Interv Cardiol. 1995 Oct;8(5):543–556. doi: 10.1111/j.1540-8183.1995.tb00582.x. [DOI] [PubMed] [Google Scholar]
  6. Benson L., McLaughlin P. R., Webb G. D. The European experience with coil occlusion of PDA: strength in numbers. Eur Heart J. 2001 Oct;22(19):1768–1769. doi: 10.1053/euhj.2001.2755. [DOI] [PubMed] [Google Scholar]
  7. Bonhoeffer P., Esteves C., Casal U., Tortoledo F., Yonga G., Patel T., Chisholm R., Luxereau P., Ruiz C. Percutaneous mitral valve dilatation with the Multi-Track System. Catheter Cardiovasc Interv. 1999 Oct;48(2):178–183. doi: 10.1002/(sici)1522-726x(199910)48:2<178::aid-ccd11>3.0.co;2-5. [DOI] [PubMed] [Google Scholar]
  8. Bonhoeffer Philipp, Boudjemline Younes, Qureshi Shakeel A., Le Bidois Jerome, Iserin Laurence, Acar Philippe, Merckx Jacques, Kachaner Jean, Sidi Daniel. Percutaneous insertion of the pulmonary valve. J Am Coll Cardiol. 2002 May 15;39(10):1664–1669. doi: 10.1016/s0735-1097(02)01822-3. [DOI] [PubMed] [Google Scholar]
  9. Boudjemline Younes, Bonhoeffer Philipp. Steps toward percutaneous aortic valve replacement. Circulation. 2002 Feb 12;105(6):775–778. doi: 10.1161/hc0602.103361. [DOI] [PubMed] [Google Scholar]
  10. Carminati M., Giusti S., Hausdorf G., Qureshi S., Tynan M., Witsenburg M., Hess J., Piechaud J. F., Bonhoeffer P., Donti A. A European multicentric experience using the CardioSEal and Starflex double umbrella devices to close interatrial communications holes within the oval fossa. Cardiol Young. 2000 Sep;10(5):519–526. doi: 10.1017/s1047951100008210. [DOI] [PubMed] [Google Scholar]
  11. Chessa Massimo, Carminati Mario, Cao Qi-Ling, Butera Gianfranco, Giusti Sandra, Bini Roberta Margherita, Hijazi Ziyad M. Transcatheter closure of congenital and acquired muscular ventricular septal defects using the Amplatzer device. J Invasive Cardiol. 2002 Jun;14(6):322–327. [PubMed] [Google Scholar]
  12. Duke C., Qureshi S. A. Aortic coarctation and recoarctation: to stent or not to stent? J Interv Cardiol. 2001 Jun;14(3):283–298. doi: 10.1111/j.1540-8183.2001.tb00335.x. [DOI] [PubMed] [Google Scholar]
  13. Echigo S. Balloon valvuloplasty for congenital heart disease: immediate and long-term results of multi-institutional study. Pediatr Int. 2001 Oct;43(5):542–547. doi: 10.1046/j.1442-200x.2001.01461.x. [DOI] [PubMed] [Google Scholar]
  14. Fischer G., Stieh J., Uebing A., Hoffmann U., Morf G., Kramer H. H. Experience with transcatheter closure of secundum atrial septal defects using the Amplatzer septal occluder: a single centre study in 236 consecutive patients. Heart. 2003 Feb;89(2):199–204. doi: 10.1136/heart.89.2.199. [DOI] [PMC free article] [PubMed] [Google Scholar]
  15. Hijazi Ziyad M. Device closure of ventricular septal defects. Catheter Cardiovasc Interv. 2003 Sep;60(1):107–114. doi: 10.1002/ccd.10567. [DOI] [PubMed] [Google Scholar]
  16. Hornung T. S., Benson L. N., McLaughlin P. R. Interventions for aortic coarctation. Cardiol Rev. 2002 May-Jun;10(3):139–148. doi: 10.1097/00045415-200205000-00002. [DOI] [PubMed] [Google Scholar]
  17. Levi Daniel S., Alejos Juan C., Moore John W. Future of interventional cardiology in pediatrics. Curr Opin Cardiol. 2003 Mar;18(2):79–90. doi: 10.1097/00001573-200303000-00002. [DOI] [PubMed] [Google Scholar]
  18. Lopez Leo, Ventura Roque, Welch Elizabeth M., Nykanen David G., Zahn Evan M. Echocardiographic considerations during deployment of the Helex Septal Occluder for closure of atrial septal defects. Cardiol Young. 2003 Jun;13(3):290–298. [PubMed] [Google Scholar]
  19. Okubo M., Benson L. N. Intravascular and intracardiac stents used in congenital heart disease. Curr Opin Cardiol. 2001 Mar;16(2):84–91. doi: 10.1097/00001573-200103000-00002. [DOI] [PubMed] [Google Scholar]
  20. Ovaert C., Qureshi S. A., Rosenthal E., Baker E. J., Tynan M. Growth of the right ventricle after successful transcatheter pulmonary valvotomy in neonates and infants with pulmonary atresia and intact ventricular septum. J Thorac Cardiovasc Surg. 1998 May;115(5):1055–1062. doi: 10.1016/S0022-5223(98)70405-2. [DOI] [PubMed] [Google Scholar]
  21. Pedra Carlos A. C., Pedra Simone R. F., Esteves Cesar A., Pontes Sérgio C., Jr, Braga Sérgio L. N., Arrieta S. Raul, Santana M. Virgínia T., Fontes Valmir F., Masura Jozef. Percutaneous closure of perimembranous ventricular septal defects with the Amplatzer device: technical and morphological considerations. Catheter Cardiovasc Interv. 2004 Mar;61(3):403–410. doi: 10.1002/ccd.10797. [DOI] [PubMed] [Google Scholar]
  22. Qureshi S. A., Redington A. N., Wren C., Ostman-Smith I., Patel R., Gibbs J. L., de Giovanni J. Recommendations of the British Paediatric Cardiac Association for therapeutic cardiac catheterisation in congenital cardiac disease. Cardiol Young. 2000 Nov;10(6):649–667. doi: 10.1017/s1047951100008982. [DOI] [PubMed] [Google Scholar]
  23. Razavi Reza, Hill Derek L. G., Keevil Stephen F., Miquel Marc E., Muthurangu Vivek, Hegde Sanjeet, Rhode Kawal, Barnett Michael, van Vaals Joop, Hawkes David J. Cardiac catheterisation guided by MRI in children and adults with congenital heart disease. Lancet. 2003 Dec 6;362(9399):1877–1882. doi: 10.1016/S0140-6736(03)14956-2. [DOI] [PubMed] [Google Scholar]
  24. Rueda F., Squitieri C., Ballerini L. Closure of the fenestration in the extracardiac Fontan with the Amplatzer duct occluder device. Catheter Cardiovasc Interv. 2001 Sep;54(1):88–92. doi: 10.1002/ccd.1245. [DOI] [PubMed] [Google Scholar]
  25. Ruiz C. E., Bailey L. L. Stenting the ductus arteriosus: A "wanna-be" Blalock-Taussig. Circulation. 1999 May 25;99(20):2608–2609. doi: 10.1161/01.cir.99.20.2608. [DOI] [PubMed] [Google Scholar]
  26. Trivedi Kalyani R., Benson Lee N. Interventional strategies in the management of peripheral pulmonary artery stenosis. J Interv Cardiol. 2003 Apr;16(2):171–188. doi: 10.1046/j.1540-8183.2003.08031.x. [DOI] [PubMed] [Google Scholar]
  27. Waight D. J., Hijazi Z. M. Pediatric interventional cardiology: the cardiologist's role and relationship with pediatric cardiothoracic surgery. Adv Card Surg. 2001;13:143–167. [PubMed] [Google Scholar]
  28. Waight David J., Cao Qi-Ling, Hijazi Ziyad M. Transcatheter Closure of Patent Ductus Arteriosus Using the Amplatzer Duct Occluder. Curr Interv Cardiol Rep. 2001 Aug;3(3):263–267. [PubMed] [Google Scholar]
  29. Wren C. Catheter ablation in paediatric arrhythmias. Arch Dis Child. 1999 Aug;81(2):102–104. doi: 10.1136/adc.81.2.102. [DOI] [PMC free article] [PubMed] [Google Scholar]
  30. Zellers Thomas M., Dixon Keith, Moake Lindy, Wright Janis, Ramaciotti Claudio. Bedside balloon atrial septostomy is safe, efficacious, and cost-effective compared with septostomy performed in the cardiac catheterization laboratory. Am J Cardiol. 2002 Mar 1;89(5):613–615. doi: 10.1016/s0002-9149(01)02309-8. [DOI] [PubMed] [Google Scholar]

Articles from Archives of Disease in Childhood are provided here courtesy of BMJ Publishing Group

RESOURCES