Abstract
AIMS—To compare arterial blood gas (ABG) readings obtained with a multiparameter intra-arterial sensor with those from an ABG analyser. METHODS—An MPIAS with the ability to measure continuously pH, PaCO2, and PaO2 was introduced via an umbilical arterial catheter in 27 neonates requiring intensive care. They underwent 3260 hours of MPIAS monitoring, during which 753 ABG readings were performed. RESULTS—Overall bias (mean difference: MPIAS-ABG) and precision (standard deviation of differences) values were: −0.002 and 0.022,respectively, for pH; +0.26 and 0.52 for PaCO2 (kPa); and −0.19 and 0.99 for PaO2 (kPa). This gave 95% limits of agreement as: −0.047 to +0.042 for pH, −0.76 to +1.28 kPa for PaCO2, and −2.13 to +1.75 kPa for PaO2. For each variable, precision across readings from the same individual was better than overall precision for all data. No complications related to the use of the catheter were observed. CONCLUSIONS—Continuous MPIAS ABG monitoring is an exciting development, with the potential to reduce blood transfusions and improve ABG homeostasis.
Full Text
The Full Text of this article is available as a PDF (124.4 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Bland J. M., Altman D. G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986 Feb 8;1(8476):307–310. [PubMed] [Google Scholar]
- Brünstler I., Enders A., Versmold H. T. Skin surface PCO2 monitoring in newborn infants in shock: effect of hypotension and electrode temperature. J Pediatr. 1982 Mar;100(3):454–457. doi: 10.1016/s0022-3476(82)80459-9. [DOI] [PubMed] [Google Scholar]
- Carter B., Hochmann M., Osborne A., Nisbet A., Campbell N. A comparison of two transcutaneous monitors for the measurement of arterial PO2 and PCO2 in neonates. Anaesth Intensive Care. 1995 Dec;23(6):708–714. doi: 10.1177/0310057X9502300610. [DOI] [PubMed] [Google Scholar]
- Cassady G. Transcutaneous monitoring in the newborn infant. J Pediatr. 1983 Dec;103(6):837–848. doi: 10.1016/s0022-3476(83)80698-2. [DOI] [PubMed] [Google Scholar]
- Chan V., Greenough A. The effect of frequency on carbon dioxide levels during high frequency oscillation. J Perinat Med. 1994;22(2):103–106. doi: 10.1515/jpme.1994.22.2.103. [DOI] [PubMed] [Google Scholar]
- Cooke R. W. Factors associated with periventricular haemorrhage in very low birthweight infants. Arch Dis Child. 1981 Jun;56(6):425–431. doi: 10.1136/adc.56.6.425. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Dear P. R. Monitoring oxygen in the newborn: saturation or partial pressure? Arch Dis Child. 1987 Sep;62(9):879–881. doi: 10.1136/adc.62.9.879. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Goddard P., Keith I., Marcovitch H., Roberton N. R., Rolfe P., Scopes J. W. Use of a continuously recording intravascular oxygen electrode in the newborn. Arch Dis Child. 1974 Nov;49(11):853–860. doi: 10.1136/adc.49.11.853. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Greisen G., Munck H., Lou H. Severe hypocarbia in preterm infants and neurodevelopmental deficit. Acta Paediatr Scand. 1987 May;76(3):401–404. doi: 10.1111/j.1651-2227.1987.tb10489.x. [DOI] [PubMed] [Google Scholar]
- Hansen T. N., Tooley W. H. Skin surface carbon dioxide tension in sick infants. Pediatrics. 1979 Dec;64(6):942–945. [PubMed] [Google Scholar]
- Ikonen R. S., Janas M. O., Koivikko M. J., Laippala P., Kuusinen E. J. Hyperbilirubinemia, hypocarbia and periventricular leukomalacia in preterm infants: relationship to cerebral palsy. Acta Paediatr. 1992 Oct;81(10):802–807. doi: 10.1111/j.1651-2227.1992.tb12107.x. [DOI] [PubMed] [Google Scholar]
- Jennis M. S., Peabody J. L. Pulse oximetry: an alternative method for the assessment of oxygenation in newborn infants. Pediatrics. 1987 Apr;79(4):524–528. [PubMed] [Google Scholar]
- Kampelmacher M. J., van Kesteren R. G., Winckers E. K. Instrumental variability of respiratory blood gases among different blood gas analysers in different laboratories. Eur Respir J. 1997 Jun;10(6):1341–1344. doi: 10.1183/09031936.97.10061341. [DOI] [PubMed] [Google Scholar]
- Kost G. J., Chow J. L., Kenny M. A. Monitoring of transcutaneous carbon dioxide tension. Am J Clin Pathol. 1983 Dec;80(6):832–838. doi: 10.1093/ajcp/80.6.832. [DOI] [PubMed] [Google Scholar]
- Kresch M. J., Lin W. H., Thrall R. S. Surfactant replacement therapy. Thorax. 1996 Nov;51(11):1137–1154. doi: 10.1136/thx.51.11.1137. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Leahy F. A., Cates D., MacCallum M., Rigatto H. Effect of CO2 and 100% O2 on cerebral blood flow in preterm infants. J Appl Physiol Respir Environ Exerc Physiol. 1980 Mar;48(3):468–472. doi: 10.1152/jappl.1980.48.3.468. [DOI] [PubMed] [Google Scholar]
- Levene M. I., Fawer C. L., Lamont R. F. Risk factors in the development of intraventricular haemorrhage in the preterm neonate. Arch Dis Child. 1982 Jun;57(6):410–417. doi: 10.1136/adc.57.6.410. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Mahutte C. K., Holody M., Maxwell T. P., Chen P. A., Sasse S. A. Development of a patient-dedicated, on-demand, blood gas monitor. Am J Respir Crit Care Med. 1994 Apr;149(4 Pt 1):852–859. doi: 10.1164/ajrccm.149.4.8143046. [DOI] [PubMed] [Google Scholar]
- Martin R. J., Beoglos A., Miller M. J., DiFiore J. M., Robertson S. S., Carlo W. A. Increasing arterial carbon dioxide tension: influence on transcutaneous carbon dioxide tension measurements. Pediatrics. 1988 May;81(5):684–687. [PubMed] [Google Scholar]
- Pollitzer M. J., Soutter L. P., Reynolds E. O. Continuous monitoring of arterial oxygen tension in infants: four years of experience with an intravascular oxygen electrode. Pediatrics. 1980 Jul;66(1):31–36. [PubMed] [Google Scholar]
- Rennie J. M. Transcutaneous carbon dioxide monitoring. Arch Dis Child. 1990 Apr;65(4 Spec No):345–346. doi: 10.1136/adc.65.4_spec_no.345. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Venkatesh B., Clutton Brock T. H., Hendry S. P. A multiparameter sensor for continuous intra-arterial blood gas monitoring: a prospective evaluation. Crit Care Med. 1994 Apr;22(4):588–594. doi: 10.1097/00003246-199404000-00013. [DOI] [PubMed] [Google Scholar]
- Venkatesh B., Clutton-Brock T. H., Hendry S. P. Continuous measurement of blood gases using a combined electrochemical and spectrophotometric sensor. J Med Eng Technol. 1994 Sep-Oct;18(5):165–168. doi: 10.3109/03091909409030246. [DOI] [PubMed] [Google Scholar]
- Wahr J. A., Lau W., Tremper K. K., Hallock L., Smith K. Accuracy and precision of a new, portable, handheld blood gas analyzer, the IRMA. J Clin Monit. 1996 Jul;12(4):317–324. doi: 10.1007/BF02221753. [DOI] [PubMed] [Google Scholar]
- Weiss I. K., Fink S., Edmunds S., Harrison R., Donnelly K. Continuous arterial gas monitoring: initial experience with the Paratrend 7 in children. Intensive Care Med. 1996 Dec;22(12):1414–1417. doi: 10.1007/BF01709562. [DOI] [PubMed] [Google Scholar]
- Wilkinson A. R., Phibbs R. H., Gregory G. A. Improved accuracy of continuous measurement of arterial oxygen tension in sick newborn infants. Criteria for reading and recalibrating the electrode. Arch Dis Child. 1979 Apr;54(4):307–310. doi: 10.1136/adc.54.4.307. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wimberley P. D., Frederiksen P. S., Witt-Hansen J., Melberg S. G., Friis-Hansen B. Evaluation of a transcutaneous oxygen and carbon dioxide monitor in a neonatal intensive care department. Acta Paediatr Scand. 1985 May;74(3):352–359. doi: 10.1111/j.1651-2227.1985.tb10983.x. [DOI] [PubMed] [Google Scholar]
- Zaloga G. P., Roberts P. R., Black K., Santamauro J. T., Klase E., Suleiman M. Hand-held blood gas analyzer is accurate in the critical care setting. Crit Care Med. 1996 Jun;24(6):957–962. doi: 10.1097/00003246-199606000-00014. [DOI] [PubMed] [Google Scholar]
- Zollinger A., Spahn D. R., Singer T., Zalunardo M. P., Stoehr S., Weder W., Pasch T. Accuracy and clinical performance of a continuous intra-arterial blood-gas monitoring system during thoracoscopic surgery. Br J Anaesth. 1997 Jul;79(1):47–52. doi: 10.1093/bja/79.1.47. [DOI] [PubMed] [Google Scholar]