Abstract
Background: When the ductus arteriosus (DA) is patent, the ductal shunt is proportional to the ratio of left ventricular output (LVO) to systemic blood flow. Systemic blood flow can be estimated by measuring flow in the superior vena cava (SVC).
Objective: To re-evaluate the accuracy of standard echocardiographic markers of patent ductus arteriosus (PDA) using LVO/SVC flow ratio.
Methods: Prospective study. Preterm infants of 24–30 weeks gestational age and postnatal age less than 48 hours. The following echocardiographic criteria were measured: left atrial to aortic root ratio (LA/Ao); DA diameter by B mode and colour Doppler; mean and end diastolic flow velocity of the left pulmonary artery (LPA); LVO; SVC flow.
Results: Twenty three preterm infants were enrolled (median gestational age 28 weeks (range 24–30), median birth weight 840 g (500–1440)). The DA was closed in eight (mean (SD) LVO/SVC 2.4 (0.3)) and open in 15 (mean (SD) LVO/SVC 4.5 (0.6)). An LA/Ao ratio ⩾1.4, a DA diameter ⩾1.4 mm/kg, and a mean and end diastolic flow velocity of LPA respectively ⩾0.42 and ⩾0.20 m/s identified an LVO/SVC ⩾4 with a sensitivity and a specificity above 90%.
Conclusion: This study indicates that LA/Ao ratio, DA diameter, and mean and end diastolic flow velocity of the LPA are accurate markers of PDA. These standard echocardiographic variables are easy to measure and need less skill and resources than direct measurements of ductal shunt.
Full Text
The Full Text of this article is available as a PDF (127.0 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Alverson D. C., Eldridge M., Aldrich M., Werner S. B., Angelus P., Berman W., Jr Effect of patent ductus arteriosus on lower extremity blood flow velocity patterns in preterm infants. Am J Perinatol. 1984 Apr;1(3):216–222. doi: 10.1055/s-2007-1000008. [DOI] [PubMed] [Google Scholar]
- Bömelburg T., Jorch G. Abnormal blood flow patterns in renal arteries of small preterm infants with patent ductus arteriosus detected by Doppler ultrasonography. Eur J Pediatr. 1989 Jun;148(7):660–664. doi: 10.1007/BF00441528. [DOI] [PubMed] [Google Scholar]
- Bömelburg T., Jorch G. Abnormal blood flow patterns in renal arteries of small preterm infants with patent ductus arteriosus detected by Doppler ultrasonography. Eur J Pediatr. 1989 Jun;148(7):660–664. doi: 10.1007/BF00441528. [DOI] [PubMed] [Google Scholar]
- Cheifetz I. M., Meliones J. N. Hemodynamic effects of high-frequency oscillatory ventilation: a little volume goes a long way. Crit Care Med. 2000 Jan;28(1):282–284. doi: 10.1097/00003246-200001000-00064. [DOI] [PubMed] [Google Scholar]
- Davies M. W., Betheras F. R., Swaminathan M. A preliminary study of the application of the transductal velocity ratio for assessing persistent ductus arteriosus. Arch Dis Child Fetal Neonatal Ed. 2000 May;82(3):F195–F199. doi: 10.1136/fn.82.3.F195. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ellison R. C., Peckham G. J., Lang P., Talner N. S., Lerer T. J., Lin L., Dooley K. J., Nadas A. S. Evaluation of the preterm infant for patent ductus arteriosus. Pediatrics. 1983 Mar;71(3):364–372. [PubMed] [Google Scholar]
- Evans N. Diagnosis of patent ductus arteriosus in the preterm newborn. Arch Dis Child. 1993 Jan;68(1 Spec No):58–61. doi: 10.1136/adc.68.1_spec_no.58. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Evans N., Iyer P. Assessment of ductus arteriosus shunt in preterm infants supported by mechanical ventilation: effect of interatrial shunting. J Pediatr. 1994 Nov;125(5 Pt 1):778–785. doi: 10.1016/s0022-3476(94)70078-8. [DOI] [PubMed] [Google Scholar]
- Evans N., Iyer P. Incompetence of the foramen ovale in preterm infants supported by mechanical ventilation. J Pediatr. 1994 Nov;125(5 Pt 1):786–792. doi: 10.1016/s0022-3476(94)70079-6. [DOI] [PubMed] [Google Scholar]
- Gournay V., Cambonie G., Rozé J. C. Doppler echocardiographic assessment of pulmonary blood flow in healthy newborns. Acta Paediatr. 1998 Apr;87(4):419–423. doi: 10.1080/08035259850157020. [DOI] [PubMed] [Google Scholar]
- Hirsimäki H., Kero P., Wanne O. Doppler ultrasound and clinical evaluation in detection and grading of patient ductus arteriosus in neonates. Crit Care Med. 1990 May;18(5):490–493. doi: 10.1097/00003246-199005000-00005. [DOI] [PubMed] [Google Scholar]
- Ichihashi K., Shiraishi H., Endou H., Kuramatsu T., Yano S., Yanagisawa M. Cerebral and abdominal arterial hemodynamics in preterm infants with patent ductus arteriosus. Acta Paediatr Jpn. 1990 Aug;32(4):349–356. doi: 10.1111/j.1442-200x.1990.tb00842.x. [DOI] [PubMed] [Google Scholar]
- Johnson G. L., Breart G. L., Gewitz M. H., Brenner J. I., Lang P., Dooley K. J., Ellison R. C. Echocardiographic characteristics of premature infants with patient ductus arteriosus. Pediatrics. 1983 Dec;72(6):864–871. [PubMed] [Google Scholar]
- Kluckow M., Evans N. Ductal shunting, high pulmonary blood flow, and pulmonary hemorrhage. J Pediatr. 2000 Jul;137(1):68–72. doi: 10.1067/mpd.2000.106569. [DOI] [PubMed] [Google Scholar]
- Kluckow M., Evans N. Early echocardiographic prediction of symptomatic patent ductus arteriosus in preterm infants undergoing mechanical ventilation. J Pediatr. 1995 Nov;127(5):774–779. doi: 10.1016/s0022-3476(95)70172-9. [DOI] [PubMed] [Google Scholar]
- Kluckow M., Evans N. Low superior vena cava flow and intraventricular haemorrhage in preterm infants. Arch Dis Child Fetal Neonatal Ed. 2000 May;82(3):F188–F194. doi: 10.1136/fn.82.3.F188. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kluckow M., Evans N. Superior vena cava flow in newborn infants: a novel marker of systemic blood flow. Arch Dis Child Fetal Neonatal Ed. 2000 May;82(3):F182–F187. doi: 10.1136/fn.82.3.F182. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Kupferschmid C., Lang D., Pohlandt F. Sensitivity, specificity and predictive value of clinical findings, m-mode echocardiography and continuous-wave Doppler sonography in the diagnosis of symptomatic patent ductus arteriosus in preterm infants. Eur J Pediatr. 1988 Apr;147(3):279–282. doi: 10.1007/BF00442695. [DOI] [PubMed] [Google Scholar]
- Lindner W., Seidel M., Versmold H. T., Döhlemann C., Riegel K. P. Stroke volume and left ventricular output in preterm infants with patent ductus arteriosus. Pediatr Res. 1990 Mar;27(3):278–281. doi: 10.1203/00006450-199003000-00015. [DOI] [PubMed] [Google Scholar]
- Mandelbaum-Isken V. H., Linderkamp O. Cardiac output by pulsed Doppler in neonates using the apical window. Pediatr Cardiol. 1991 Jan;12(1):13–16. doi: 10.1007/BF02238491. [DOI] [PubMed] [Google Scholar]
- Maroto E., Fouron J. C., Aké E., van Doesburg N. H., Cartwright D., Teyssier G., Bard H. Closure of the ductus arteriosus: determinant factor in the appearance of transient peripheral pulmonary stenosis of the neonate. J Pediatr. 1991 Dec;119(6):955–959. doi: 10.1016/s0022-3476(05)83055-0. [DOI] [PubMed] [Google Scholar]
- Maruyama K., Koizumi T., Tomomasa T., Morikawa A. Intestinal blood-flow velocity in uncomplicated preterm infants during the early neonatal period. Pediatr Radiol. 1999 Jun;29(6):472–477. doi: 10.1007/s002470050621. [DOI] [PubMed] [Google Scholar]
- Phillipos E. Z., Robertson M. A., Byrne P. J. Serial assessment of ductus arteriosus hemodynamics in hyaline membrane disease. Pediatrics. 1996 Dec;98(6 Pt 1):1149–1153. [PubMed] [Google Scholar]
- Pladys P., Wodey E., Beuchée A., Branger B., Bétrémieux P. Left ventricle output and mean arterial blood pressure in preterm infants during the 1st day of life. Eur J Pediatr. 1999 Oct;158(10):817–824. doi: 10.1007/s004310051213. [DOI] [PubMed] [Google Scholar]
- Shimada S., Kasai T., Konishi M., Fujiwara T. Effects of patent ductus arteriosus on left ventricular output and organ blood flows in preterm infants with respiratory distress syndrome treated with surfactant. J Pediatr. 1994 Aug;125(2):270–277. doi: 10.1016/s0022-3476(94)70210-1. [DOI] [PubMed] [Google Scholar]
- Shortland D. B., Gibson N. A., Levene M. I., Archer L. N., Evans D. H., Shaw D. E. Patent ductus arteriosus and cerebral circulation in preterm infants. Dev Med Child Neurol. 1990 May;32(5):386–393. doi: 10.1111/j.1469-8749.1990.tb16957.x. [DOI] [PubMed] [Google Scholar]
- Skelton R., Evans N., Smythe J. A blinded comparison of clinical and echocardiographic evaluation of the preterm infant for patent ductus arteriosus. J Paediatr Child Health. 1994 Oct;30(5):406–411. doi: 10.1111/j.1440-1754.1994.tb00689.x. [DOI] [PubMed] [Google Scholar]
- Suzumura H., Nitta A., Tanaka G., Arisaka O. Diastolic flow velocity of the left pulmonary artery of patent ductus arteriosus in preterm infants. Pediatr Int. 2001 Apr;43(2):146–151. doi: 10.1046/j.1442-200x.2001.01365.x. [DOI] [PubMed] [Google Scholar]
- Walther F. J., Kim D. H., Ebrahimi M., Siassi B. Pulsed Doppler measurement of left ventricular output as early predictor of symptomatic patent ductus arteriosus in very preterm infants. Biol Neonate. 1989;56(3):121–128. doi: 10.1159/000243112. [DOI] [PubMed] [Google Scholar]