Abstract
AIMS—A case-control study was performed to evaluate soft contact lens (SCL) wear modality as a risk factor for microbial keratitis. METHODS—Contact lens wearers presenting as new patients to Moorfields Eye Hospital accident and emergency department during a 12 month period completed a self administered questionnaire detailing demographic data and contact lens use habits. Cases were patients with a clinical diagnosis of SCL related microbial keratitis. Controls were SCL users attending with disorders unrelated to contact lens wear. Odds ratios (estimates of relative risks) and 95% confidence limits (CL) were calculated through multivariable logistic regression analysis. RESULTS—There were 89 cases and 566 controls. A substantially increased risk with 1-4 weekly disposable SCL compared with non-disposable SCL was identified among both daily wear (DW) (odds ratio =3.51, 95% CL 1.60-7.66, p=0.002) and extended wear (odds ratio 4.76, 95% CL 1.52-14.87, p=0.007) users after adjustment for demographic, lens use and hygiene variables. Other significant factors among DW users were "occasional" overnight use, use of chlorine based (as opposed to other chemical) systems in combination with poor storage case hygiene, and irregular disinfection. CONCLUSION—Properties of some disposable SCL may be partly responsible for these excess risks. It is also possible, however, that this finding is largely a reflection of widespread complacency among patients and practitioners with respect to disposable SCL fitting and use. Keywords: microbial keratitis; disposable contact lenses
Full Text
The Full Text of this article is available as a PDF (68.3 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Brennan N. A., Lowe R., Efron N., Harris M. G. In vivo dehydration of disposable (Acuvue) contact lenses. Optom Vis Sci. 1990 Mar;67(3):201–203. doi: 10.1097/00006324-199003000-00010. [DOI] [PubMed] [Google Scholar]
- Buehler P. O., Schein O. D., Stamler J. F., Verdier D. D., Katz J. The increased risk of ulcerative keratitis among disposable soft contact lens users. Arch Ophthalmol. 1992 Nov;110(11):1555–1558. doi: 10.1001/archopht.1992.01080230055019. [DOI] [PubMed] [Google Scholar]
- Cutter G. R., Chalmers R. L., Roseman M. The clinical presentation, prevalence, and risk factors of focal corneal infiltrates in soft contact lens wearers. CLAO J. 1996 Jan;22(1):30–37. [PubMed] [Google Scholar]
- Dart J. K., Stapleton F., Minassian D. Contact lenses and other risk factors in microbial keratitis. Lancet. 1991 Sep 14;338(8768):650–653. doi: 10.1016/0140-6736(91)91231-i. [DOI] [PubMed] [Google Scholar]
- Hamano H., Watanabe K., Hamano T., Mitsunaga S., Kotani S., Okada A. A study of the complications induced by conventional and disposable contact lenses. CLAO J. 1994 Apr;20(2):103–108. [PubMed] [Google Scholar]
- Helton D. O., Watson L. S. Hydrogel contact lens dehydration rates determined by thermogravimetric analysis. CLAO J. 1991 Jan;17(1):59–61. [PubMed] [Google Scholar]
- Matthews T. D., Frazer D. G., Minassian D. C., Radford C. F., Dart J. K. Risks of keratitis and patterns of use with disposable contact lenses. Arch Ophthalmol. 1992 Nov;110(11):1559–1562. doi: 10.1001/archopht.1992.01080230059020. [DOI] [PubMed] [Google Scholar]
- Nason R. J., Boshnick E. L., Cannon W. M., Dubow B. W., Freeman M. I., Kame R. T., Lanier J. C., Jr, Lopanik R. W., Quinn T. G., Jr, Rigel L. E. Multisite comparison of contact lens modalities. Daily disposable wear vs. conventional daily wear in successful contact lens wearers. J Am Optom Assoc. 1994 Nov;65(11):774–780. [PubMed] [Google Scholar]
- Nilsson S. E., Montan P. G. The annualized incidence of contact lens induced keratitis in Sweden and its relation to lens type and wear schedule: results of a 3-month prospective study. CLAO J. 1994 Oct;20(4):225–230. doi: 10.1097/00140068-199410000-00006. [DOI] [PubMed] [Google Scholar]
- Nilsson S. E., Montan P. G. The hospitalized cases of contact lens induced keratitis in Sweden and their relation to lens type and wear schedule: results of a three-year retrospective study. CLAO J. 1994 Apr;20(2):97–101. [PubMed] [Google Scholar]
- Poggio E. C., Abelson M. B. Complications and symptoms with disposable daily wear contact lenses and conventional soft daily wear contact lenses. CLAO J. 1993 Apr;19(2):95–102. [PubMed] [Google Scholar]
- Poggio E. C., Abelson M. Complications and symptoms in disposable extended wear lenses compared with conventional soft daily wear and soft extended wear lenses. CLAO J. 1993 Jan;19(1):31–39. doi: 10.1097/00140068-199301000-00006. [DOI] [PubMed] [Google Scholar]
- Pritchard N., Fonn D. Dehydration, lens movement and dryness ratings of hydrogel contact lenses. Ophthalmic Physiol Opt. 1995 Jul;15(4):281–286. [PubMed] [Google Scholar]
- Radford C. F., Bacon A. S., Dart J. K., Minassian D. C. Risk factors for acanthamoeba keratitis in contact lens users: a case-control study. BMJ. 1995 Jun 17;310(6994):1567–1570. doi: 10.1136/bmj.310.6994.1567. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sack R. A., Jones B., Antignani A., Libow R., Harvey H. Specificity and biological activity of the protein deposited on the hydrogel surface. Relationship of polymer structure to biofilm formation. Invest Ophthalmol Vis Sci. 1987 May;28(5):842–849. [PubMed] [Google Scholar]
- Schein O. D., Buehler P. O., Stamler J. F., Verdier D. D., Katz J. The impact of overnight wear on the risk of contact lens-associated ulcerative keratitis. Arch Ophthalmol. 1994 Feb;112(2):186–190. doi: 10.1001/archopht.1994.01090140062024. [DOI] [PubMed] [Google Scholar]
- Schein O. D., Glynn R. J., Poggio E. C., Seddon J. M., Kenyon K. R. The relative risk of ulcerative keratitis among users of daily-wear and extended-wear soft contact lenses. A case-control study. Microbial Keratitis Study Group. N Engl J Med. 1989 Sep 21;321(12):773–778. doi: 10.1056/NEJM198909213211201. [DOI] [PubMed] [Google Scholar]
- Solomon O. D., Freeman M. I., Boshnick E. L., Cannon W. M., Dubow B. W., Kame R. T., Lanier J. C., Jr, Lopanik R. W., Quinn T. G., Rigel L. E. A 3-year prospective study of the clinical performance of daily disposable contact lenses compared with frequent replacement and conventional daily wear contact lenses. CLAO J. 1996 Oct;22(4):250–257. [PubMed] [Google Scholar]
- Stapleton F., Dart J. K., Minassian D. Risk factors with contact lens related suppurative keratitis. CLAO J. 1993 Oct;19(4):204–210. [PubMed] [Google Scholar]