Abstract
BACKGROUND—Corneal infections due to contact lens contamination are risks associated with contact lens wear. Care systems which reduce these risks are desirable. METHODS—This study evaluated a contact lens cleaning device using normal saline initially and then four contact lens solutions. RESULTS—Using saline, six out of 10 tests resulted in complete removal of challenge organisms or showed reductions to 10 cfu/ml or <10 cfu/ml. Tests upon organism using multipurpose solutions showed >6 log reductions in 2-3 minutes. With laboratory made biofilms, similar results were obtained. CONCLUSIONS—This device improves lens cleaning and enhances lens care solutions. When used correctly it should lead to significant reductions in microbial keratitis associated with inadequate contact lens hygiene.
Full Text
The Full Text of this article is available as a PDF (91.6 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Dart J. K. Disease and risks associated with contact lenses. Br J Ophthalmol. 1993 Jan;77(1):49–53. doi: 10.1136/bjo.77.1.49. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Gray T. B., Cursons R. T., Sherwan J. F., Rose P. R. Acanthamoeba, bacterial, and fungal contamination of contact lens storage cases. Br J Ophthalmol. 1995 Jun;79(6):601–605. doi: 10.1136/bjo.79.6.601. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Holden B. A., La Hood D., Grant T., Newton-Howes J., Baleriola-Lucas C., Willcox M. D., Sweeney D. F. Gram-negative bacteria can induce contact lens related acute red eye (CLARE) responses. CLAO J. 1996 Jan;22(1):47–52. [PubMed] [Google Scholar]
- Houlsby R. D., Ghajar M., Chavez G. Microbiological evaluation of soft contact lens disinfecting solutions. J Am Optom Assoc. 1984 Mar;55(3):205–211. [PubMed] [Google Scholar]
- Kanpolat A., Kalayci D., Arman D., Dürük K. Contamination in contact lens care systems. CLAO J. 1992 Apr;18(2):105–107. [PubMed] [Google Scholar]
- Key J. E., Monnat K. Comparative disinfectant efficacy of two disinfecting solutions against Pseudomonas aeruginosa. CLAO J. 1996 Apr;22(2):118–121. [PubMed] [Google Scholar]
- Matthews T. D., Frazer D. G., Minassian D. C., Radford C. F., Dart J. K. Risks of keratitis and patterns of use with disposable contact lenses. Arch Ophthalmol. 1992 Nov;110(11):1559–1562. doi: 10.1001/archopht.1992.01080230059020. [DOI] [PubMed] [Google Scholar]
- Rosenthal R. A., Stein J. M., McAnally C. L., Schlech B. A. A comparative study of the microbiologic effectiveness of chemical disinfectants and peroxide-neutralizer systems. CLAO J. 1995 Apr;21(2):99–110. [PubMed] [Google Scholar]
- Wilson L. A., Sawant A. D., Simmons R. B., Ahearn D. G. Microbial contamination of contact lens storage cases and solutions. Am J Ophthalmol. 1990 Aug 15;110(2):193–198. doi: 10.1016/s0002-9394(14)76991-0. [DOI] [PubMed] [Google Scholar]
