Abstract
A high-performance liquid chromatographic method for the determination of amphotericin B concentrations in human serum without bilirubin interference was developed and compared with a microbiological assay. The high-performance liquid chromatographic assay utilized a reversed-phase trimethyl silica column, simple sample preparation, and visible detection. Reproducibility studies yielded coefficient-of-variation ranges from 1.02 to 2.11% for within-day precision and 2.88 to 4.32% for between-day precision. The correlation coefficient with the microbiological assay was 0.984 for amphotericin B.
Full text
PDF


Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Bach P. R. Quantitative extraction of amphotericin B from serum and its determination by high-pressure liquid chromatography. Antimicrob Agents Chemother. 1984 Sep;26(3):314–317. doi: 10.1128/aac.26.3.314. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bannatyne R. M., Cheung R., Devlin H. R. Microassay foramphotericin B. Antimicrob Agents Chemother. 1977 Jan;11(1):44–46. doi: 10.1128/aac.11.1.44. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Golas C. L., Prober C. G., MacLeod S. M., Soldin S. J. Measurement of amphotericin B in serum or plasma by high-performance liquid chromatography. J Chromatogr. 1983 Dec 9;278(2):387–395. doi: 10.1016/s0378-4347(00)84798-2. [DOI] [PubMed] [Google Scholar]
- Granich G. G., Kobayashi G. S., Krogstad D. J. Sensitive high-pressure liquid chromatographic assay for amphotericin B which incorporates an internal standard. Antimicrob Agents Chemother. 1986 Apr;29(4):584–588. doi: 10.1128/aac.29.4.584. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Graybill J. R., Craven P. C. Antifungal agents used in systemic mycoses. Activity and therapeutic use. Drugs. 1983 Jan;25(1):41–62. doi: 10.2165/00003495-198325010-00003. [DOI] [PubMed] [Google Scholar]
- Leclercq M., Fouillit M., Panteix G., Guinet R. Reproducible measurement of amphotericin B in serum by high-performance liquid chromatography in alkaline buffer. J Chromatogr. 1985 Feb 8;337(2):423–428. doi: 10.1016/0378-4347(85)80058-x. [DOI] [PubMed] [Google Scholar]
- Mayhew J. W., Fiore C., Murray T., Barza M. An internally-standardized assay for amphotericin B in tissues and plasma. J Chromatogr. 1983 May 13;274:271–279. doi: 10.1016/s0378-4347(00)84430-8. [DOI] [PubMed] [Google Scholar]
- Miller R. P., Bates J. H. Amphotericin B toxicity. A follow-up report of 53 patients. Ann Intern Med. 1969 Dec;71(6):1089–1095. doi: 10.7326/0003-4819-71-6-1089. [DOI] [PubMed] [Google Scholar]
- Nilsson-Ehle I., Yoshikawa T. T., Edwards J. E., Schotz M. C., Guze L. B. Quantitation of amphotericin B with use of high-pressure liquid chromatography. J Infect Dis. 1977 Mar;135(3):414–422. doi: 10.1093/infdis/135.3.414. [DOI] [PubMed] [Google Scholar]
- Shadomy S., McCay J. A., Schwartz S. I. Bioassay for hamycin and amphotericin B in serum and other biological fluids. Appl Microbiol. 1969 Apr;17(4):497–503. doi: 10.1128/am.17.4.497-503.1969. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Warnock D. W., Richardson M. D., Turner A. High performance liquid chromatographic (HPLC) and other non-biological methods for quantitation of antifungal drugs. J Antimicrob Chemother. 1982 Dec;10(6):467–478. doi: 10.1093/jac/10.6.467. [DOI] [PubMed] [Google Scholar]