Skip to main content
The British Journal of Ophthalmology logoLink to The British Journal of Ophthalmology
. 2001 Aug;85(8):939–941. doi: 10.1136/bjo.85.8.939

Accuracy of intraocular lens power calculation in paediatric cataract surgery

C Tromans 1, P Haigh 1, S Biswas 1, I Lloyd 1
PMCID: PMC1724100  PMID: 11466250

Abstract

AIMS—To determine the accuracy of intraocular lens (IOL) power calculation in a group of pseudophakic children.
METHODS—A retrospective analysis of biometric and refractive data was performed on 52 eyes of 40 infants and children, who successfully underwent cataract extraction and IOL implantation. The following parameters were included: age at the time of surgery, keratometry, axial length, estimated refraction, and the power of IOL implanted. The postoperative refractive outcome was taken as the spherical equivalent of the refraction at 3 months after surgery. The prediction error was taken as the absolute difference between the estimated and actual postoperative refraction. The data were analysed to assess the effects of age at the time of surgery, keratometry, and axial length on the accuracy of calculation of IOL power.
RESULTS—For the overall group the mean and median prediction errors were 1.40 D and 0.84 D (SD 1.60). The mean and median prediction errors in eyes with axial lengths ⩾20 mm were 1.07 D and 0.71 D (SD 0.98) and in eyes <20 mm were 2.63 D and 2.61 D (SD 2.65). The mean and median prediction errors in eyes in children aged ⩾36 months were 1.06 D and 0.68 D (SD 1.02) and in children aged <36 months was 2.56 D and 2.29 D (SD 2.50). The differences between the prediction errors for both axial length and age were statistically significant (p<0.05).
CONCLUSIONS—For the overall group IOL power calculation is satisfactory. In eyes with axial lengths less than 20 mm and in children less than 36 months of age larger errors can arise. This study demonstrates the need for an IOL formula specifically designed for paediatric use.



Full Text

The Full Text of this article is available as a PDF (103.0 KB).

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Ainsworth J. R., Cohen S., Levin A. V., Rootman D. S. Pediatric cataract management with variations in surgical technique and aphakic optical correction. Ophthalmology. 1997 Jul;104(7):1096–1101. doi: 10.1016/s0161-6420(97)30179-1. [DOI] [PubMed] [Google Scholar]
  2. Andreo L. K., Wilson M. E., Saunders R. A. Predictive value of regression and theoretical IOL formulas in pediatric intraocular lens implantation. J Pediatr Ophthalmol Strabismus. 1997 Jul-Aug;34(4):240–243. doi: 10.3928/0191-3913-19970701-12. [DOI] [PubMed] [Google Scholar]
  3. Awner S., Buckley E. G., DeVaro J. M., Seaber J. H. Unilateral pseudophakia in children under 4 years. J Pediatr Ophthalmol Strabismus. 1996 Jul-Aug;33(4):230–236. doi: 10.3928/0191-3913-19960701-06. [DOI] [PubMed] [Google Scholar]
  4. Binkhorst R. D. The optical design of intraocular lens implants. Ophthalmic Surg. 1975 Fall;6(3):17–31. [PubMed] [Google Scholar]
  5. Colenbrander M. C. Calculation of the power of an iris clip lens for distant vision. Br J Ophthalmol. 1973 Oct;57(10):735–740. doi: 10.1136/bjo.57.10.735. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Dahan E., Drusedau M. U. Choice of lens and dioptric power in pediatric pseudophakia. J Cataract Refract Surg. 1997;23 (Suppl 1):618–623. doi: 10.1016/s0886-3350(97)80043-0. [DOI] [PubMed] [Google Scholar]
  7. Flitcroft D. I., Knight-Nanan D., Bowell R., Lanigan B., O'Keefe M. Intraocular lenses in children: changes in axial length, corneal curvature, and refraction. Br J Ophthalmol. 1999 Mar;83(3):265–269. doi: 10.1136/bjo.83.3.265. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Gordon R. A., Donzis P. B. Refractive development of the human eye. Arch Ophthalmol. 1985 Jun;103(6):785–789. doi: 10.1001/archopht.1985.01050060045020. [DOI] [PubMed] [Google Scholar]
  9. Holladay J. T., Gills J. P., Leidlein J., Cherchio M. Achieving emmetropia in extremely short eyes with two piggyback posterior chamber intraocular lenses. Ophthalmology. 1996 Jul;103(7):1118–1123. doi: 10.1016/s0161-6420(96)30558-7. [DOI] [PubMed] [Google Scholar]
  10. Holladay J. T. Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations. J Cataract Refract Surg. 1997 Nov;23(9):1356–1370. doi: 10.1016/s0886-3350(97)80115-0. [DOI] [PubMed] [Google Scholar]
  11. Hutchinson A. K., Drews-Botsch C., Lambert S. R. Myopic shift after intraocular lens implantation during childhood. Ophthalmology. 1997 Nov;104(11):1752–1757. doi: 10.1016/s0161-6420(97)30031-1. [DOI] [PubMed] [Google Scholar]
  12. Inagaki Y. The rapid change of corneal curvature in the neonatal period and infancy. Arch Ophthalmol. 1986 Jul;104(7):1026–1027. doi: 10.1001/archopht.1986.01050190084044. [DOI] [PubMed] [Google Scholar]
  13. Inatomi M., Ishii K., Koide R., Kora Y., Ozawa T. Intraocular lens power calculation for microphthalmos. J Cataract Refract Surg. 1997 Oct;23(8):1208–1212. doi: 10.1016/s0886-3350(97)80317-3. [DOI] [PubMed] [Google Scholar]
  14. JANSSON F., KOCK E. Determination of the velocity of ultrasound in the human lens and vitreous. Acta Ophthalmol (Copenh) 1962;40:420–433. doi: 10.1111/j.1755-3768.1962.tb02390.x. [DOI] [PubMed] [Google Scholar]
  15. Larsen J. S. The sagittal growth of the eye. 1. Ultrasonic measurement of the depth of the anterior chamber from birth to puberty. Acta Ophthalmol (Copenh) 1971;49(2):239–262. doi: 10.1111/j.1755-3768.1971.tb00949.x. [DOI] [PubMed] [Google Scholar]
  16. Manning C. A., Kloess P. M. Comparison of portable automated keratometry and manual keratometry for IOL calculation. J Cataract Refract Surg. 1997 Oct;23(8):1213–1216. doi: 10.1016/s0886-3350(97)80318-5. [DOI] [PubMed] [Google Scholar]
  17. McClatchey S. K., Parks M. M. Theoretic refractive changes after lens implantation in childhood. Ophthalmology. 1997 Nov;104(11):1744–1751. doi: 10.1016/s0161-6420(97)30032-3. [DOI] [PubMed] [Google Scholar]
  18. Olsen T., Thim K., Corydon L. Accuracy of the newer generation intraocular lens power calculation formulas in long and short eyes. J Cataract Refract Surg. 1991 Mar;17(2):187–193. doi: 10.1016/s0886-3350(13)80249-0. [DOI] [PubMed] [Google Scholar]
  19. Plager D. A., Lipsky S. N., Snyder S. K., Sprunger D. T., Ellis F. D., Sondhi N. Capsular management and refractive error in pediatric intraocular lenses. Ophthalmology. 1997 Apr;104(4):600–607. doi: 10.1016/s0161-6420(97)30264-4. [DOI] [PubMed] [Google Scholar]
  20. Retzlaff J. A., Sanders D. R., Kraff M. C. Development of the SRK/T intraocular lens implant power calculation formula. J Cataract Refract Surg. 1990 May;16(3):333–340. doi: 10.1016/s0886-3350(13)80705-5. [DOI] [PubMed] [Google Scholar]
  21. Sanders D., Retzlaff J., Kraff M., Kratz R., Gills J., Levine R., Colvard M., Weisel J., Loyd T. Comparison of the accuracy of the Binkhorst, Colenbrander, and SRK implant power prediction formulas. J Am Intraocul Implant Soc. 1981 Fall;7(4):337–340. doi: 10.1016/s0146-2776(81)80031-6. [DOI] [PubMed] [Google Scholar]
  22. Zwaan J., Mullaney P. B., Awad A., al-Mesfer S., Wheeler D. T. Pediatric intraocular lens implantation. Surgical results and complications in more than 300 patients. Ophthalmology. 1998 Jan;105(1):112–119. doi: 10.1016/s0161-6420(98)91568-8. [DOI] [PubMed] [Google Scholar]