Abstract
Methods: The standard blood culture sampling kit was supplemented with an instruction sheet on the optimal method for drawing blood cultures and a large 62% ethyl alcohol impregnated wipe.
Results: There was a statistically significant reduction in the number of contaminants (p = 0.03).
Conclusions: Simple measures to encourage skin disinfection and appropriate sampling technique will reduce the incidence of contamination of blood cultures in the A&E department.
Full Text
The Full Text of this article is available as a PDF (70.5 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Calfee David P., Farr Barry M. Comparison of four antiseptic preparations for skin in the prevention of contamination of percutaneously drawn blood cultures: a randomized trial. J Clin Microbiol. 2002 May;40(5):1660–1665. doi: 10.1128/JCM.40.5.1660-1665.2002. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Finkelstein R., Fusman R., Oren I., Kassis I., Hashman N. Clinical and epidemiologic significance of coagulase-negative staphylococci bacteremia in a tertiary care university Israeli hospital. Am J Infect Control. 2002 Feb;30(1):21–25. doi: 10.1067/mic.2002.118406. [DOI] [PubMed] [Google Scholar]
- Kelly A. M. Clinical impact of blood cultures taken in the emergency department. J Accid Emerg Med. 1998 Jul;15(4):254–256. doi: 10.1136/emj.15.4.254. [DOI] [PMC free article] [PubMed] [Google Scholar]
- McGowan J. E., Jr Changing etiology of nosocomial bacteremia and fungemia and other hospital-acquired infections. Rev Infect Dis. 1985 Jul-Aug;7 (Suppl 3):S357–S370. doi: 10.1093/clinids/7.supplement_3.s357. [DOI] [PubMed] [Google Scholar]
- Mimoz O., Karim A., Mercat A., Cosseron M., Falissard B., Parker F., Richard C., Samii K., Nordmann P. Chlorhexidine compared with povidone-iodine as skin preparation before blood culture. A randomized, controlled trial. Ann Intern Med. 1999 Dec 7;131(11):834–837. doi: 10.7326/0003-4819-131-11-199912070-00006. [DOI] [PubMed] [Google Scholar]
- Schifman R. B., Strand C. L., Meier F. A., Howanitz P. J. Blood culture contamination: a College of American Pathologists Q-Probes study involving 640 institutions and 497134 specimens from adult patients. Arch Pathol Lab Med. 1998 Mar;122(3):216–221. [PubMed] [Google Scholar]
- Sturmann K. M., Bopp J., Molinari D., Akhtar S., Murphy J. Blood cultures in adult patients released from an urban emergency department: a 15-month experience. Acad Emerg Med. 1996 Aug;3(8):768–775. doi: 10.1111/j.1553-2712.1996.tb03513.x. [DOI] [PubMed] [Google Scholar]
- Trautner Barbara W., Clarridge Jill E., Darouiche Rabih O. Skin antisepsis kits containing alcohol and chlorhexidine gluconate or tincture of iodine are associated with low rates of blood culture contamination. Infect Control Hosp Epidemiol. 2002 Jul;23(7):397–401. doi: 10.1086/502073. [DOI] [PubMed] [Google Scholar]
- Weinstein M. P. Current blood culture methods and systems: clinical concepts, technology, and interpretation of results. Clin Infect Dis. 1996 Jul;23(1):40–46. doi: 10.1093/clinids/23.1.40. [DOI] [PubMed] [Google Scholar]