Skip to main content
Journal of Clinical Pathology logoLink to Journal of Clinical Pathology
. 2001 Sep;54(9):664–668. doi: 10.1136/jcp.54.9.664

D-Dimer testing: the role of the clinical laboratory in the diagnosis of pulmonary embolism

B Mavromatis 1, C Kessler 1
PMCID: PMC1731521  PMID: 11533069

Abstract

Pulmonary embolism is a common, yet often unsuspected and unrecognised disease associated with a high mortality. New, objective, "user friendly" and cost effective diagnostic strategies are being explored. D-Dimers, the fibrinolytic degradation products of crosslinked fibrin, have emerged as the most useful of the procoagulant activity and ongoing fibrinolysis markers. D-Dimer measurements are very sensitive in excluding a diagnosis of pulmonary embolism in the setting of normal values, a low clinical suspicion, and non-diagnostic lung scans. Several assays have been developed and are reviewed.

Key Words: pulmonary embolism • D-dimer assay

Full Text

The Full Text of this article is available as a PDF (123.3 KB).

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bounameaux H., Cirafici P., de Moerloose P., Schneider P. A., Slosman D., Reber G., Unger P. F. Measurement of D-dimer in plasma as diagnostic aid in suspected pulmonary embolism. Lancet. 1991 Jan 26;337(8735):196–200. doi: 10.1016/0140-6736(91)92158-x. [DOI] [PubMed] [Google Scholar]
  2. Bounameaux H., Schneider P. A., Reber G., de Moerloose P., Krahenbuhl B. Measurement of plasma D-dimer for diagnosis of deep venous thrombosis. Am J Clin Pathol. 1989 Jan;91(1):82–85. doi: 10.1093/ajcp/91.1.82. [DOI] [PubMed] [Google Scholar]
  3. Bounameaux H., Schneider P. A., Slosman D., de Moerloose P., Reber G. Plasma D-dimer in suspected pulmonary embolism: a comparison with pulmonary angiography and ventilation--perfusion scintigraphy. Blood Coagul Fibrinolysis. 1990 Oct;1(4-5):577–579. [PubMed] [Google Scholar]
  4. Crippa L., D'Angelo S. V., Tomassini L., Rizzi B., D'Alessandro G., D'Angelo A. The utility and cost-effectiveness of D-dimer measurements in the diagnosis of deep vein thrombosis. Haematologica. 1997 Jul-Aug;82(4):446–451. [PubMed] [Google Scholar]
  5. Dale S., Gogstad G. O., Brosstad F., Godal H. C., Holtlund J., Mørk E., Brandsnes O., Borch S. M. Comparison of three D-dimer assays for the diagnosis of DVT:ELISA, latex and an immunofiltration assay (NycoCard D-Dimer). Thromb Haemost. 1994 Mar;71(3):270–274. [PubMed] [Google Scholar]
  6. Demers C., Ginsberg J. S., Johnston M., Brill-Edwards P., Panju A. D-dimer and thrombin-antithrombin III complexes in patients with clinically suspected pulmonary embolism. Thromb Haemost. 1992 Apr 2;67(4):408–412. [PubMed] [Google Scholar]
  7. Duet M., Benelhadj S., Kedra W., Vilain D., Ajzenberg C., Elkharrat D., Drouet L., Soria C., Mundler O. A new quantitative D-dimer assay appropriate in emergency: reliability of the assay for pulmonary embolism exclusion diagnosis. Thromb Res. 1998 Jul 1;91(1):1–5. doi: 10.1016/s0049-3848(98)00048-6. [DOI] [PubMed] [Google Scholar]
  8. Escoffre-Barbe M., Oger E., Leroyer C., Grimaux M., Le Moigne E., Nonent M., Bressollette L., Abgrall J. F., Soria C., Amiral J. Evaluation of a new rapid D-dimer assay for clinically suspected deep venous thrombosis (Liatest D-dimer). Am J Clin Pathol. 1998 Jun;109(6):748–753. doi: 10.1093/ajcp/109.6.748. [DOI] [PubMed] [Google Scholar]
  9. Ginsberg J. S., Wells P. S., Brill-Edwards P., Donovan D., Panju A., van Beek E. J., Patel A. Application of a novel and rapid whole blood assay for D-dimer in patients with clinically suspected pulmonary embolism. Thromb Haemost. 1995 Jan;73(1):35–38. [PubMed] [Google Scholar]
  10. Ginsberg J. S., Wells P. S., Kearon C., Anderson D., Crowther M., Weitz J. I., Bormanis J., Brill-Edwards P., Turpie A. G., MacKinnon B. Sensitivity and specificity of a rapid whole-blood assay for D-dimer in the diagnosis of pulmonary embolism. Ann Intern Med. 1998 Dec 15;129(12):1006–1011. doi: 10.7326/0003-4819-129-12-199812150-00003. [DOI] [PubMed] [Google Scholar]
  11. Goldhaber S. Z., Simons G. R., Elliott C. G., Haire W. D., Toltzis R., Blacklow S. C., Doolittle M. H., Weinberg D. S. Quantitative plasma D-dimer levels among patients undergoing pulmonary angiography for suspected pulmonary embolism. JAMA. 1993 Dec 15;270(23):2819–2822. [PubMed] [Google Scholar]
  12. Goldhaber S. Z., Vaughan D. E., Tumeh S. S., Loscalzo J. Utility of cross-linked fibrin degradation products in the diagnosis of pulmonary embolism. Am Heart J. 1988 Aug;116(2 Pt 1):505–508. doi: 10.1016/0002-8703(88)90625-4. [DOI] [PubMed] [Google Scholar]
  13. Goodman L. R., Curtin J. J., Mewissen M. W., Foley W. D., Lipchik R. J., Crain M. R., Sagar K. B., Collier B. D. Detection of pulmonary embolism in patients with unresolved clinical and scintigraphic diagnosis: helical CT versus angiography. AJR Am J Roentgenol. 1995 Jun;164(6):1369–1374. doi: 10.2214/ajr.164.6.7754875. [DOI] [PubMed] [Google Scholar]
  14. Harrison K. A., Haire W. D., Pappas A. A., Purnell G. L., Palmer S., Holdeman K. P., Fink L. M., Dalrymple G. V. Plasma D-dimer: a useful tool for evaluating suspected pulmonary embolus. J Nucl Med. 1993 Jun;34(6):896–898. [PubMed] [Google Scholar]
  15. Killick S. B., Pentek P. G., Mercieca J. E., Clarke M. F., Bevan D. H. Comparison of immunofiltration assay of plasma D-dimer with diagnostic imaging in deep vein thrombosis. Br J Haematol. 1997 Mar;96(4):846–849. doi: 10.1046/j.1365-2141.1997.d01-2097.x. [DOI] [PubMed] [Google Scholar]
  16. Knecht M. F., Heinrich F. Clinical evaluation of an immunoturbidimetric D-dimer assay in the diagnostic procedure of deep vein thrombosis and pulmonary embolism. Thromb Res. 1997 Dec 1;88(5):413–417. doi: 10.1016/s0049-3848(97)00276-4. [DOI] [PubMed] [Google Scholar]
  17. Laaban J. P., Achkar A., Horellou M. H., Conard J., Bouarfa N., Arkam R., Lorut C., Fretault J., Vadrot D., Samama M. Intérêt du dosage des D-dimères plasmatiques dans le diagnostic des accidents thrombo-emboliques veineux. Rev Mal Respir. 1997 Apr;14(2):119–127. [PubMed] [Google Scholar]
  18. Lee A. Y., Julian J. A., Levine M. N., Weitz J. I., Kearon C., Wells P. S., Ginsberg J. S. Clinical utility of a rapid whole-blood D-dimer assay in patients with cancer who present with suspected acute deep venous thrombosis. Ann Intern Med. 1999 Sep 21;131(6):417–423. doi: 10.7326/0003-4819-131-6-199909210-00004. [DOI] [PubMed] [Google Scholar]
  19. Leroyer C., Escoffre M., Le Moigne E., Grimaux M., Cagnioncle O., Oger E., Bressollette L., Abgrall J. F., Amiral J., Mottier D. Diagnostic value of a new sensitive membrane based technique for instantaneous D-dimer evaluation in patients with clinically suspected deep venous thrombosis. Thromb Haemost. 1997 Apr;77(4):637–640. [PubMed] [Google Scholar]
  20. Lesser B. A., Leeper K. V., Jr, Stein P. D., Saltzman H. A., Chen J., Thompson B. T., Hales C. A., Popovich J., Jr, Greenspan R. H., Weg J. G. The diagnosis of acute pulmonary embolism in patients with chronic obstructive pulmonary disease. Chest. 1992 Jul;102(1):17–22. doi: 10.1378/chest.102.1.17. [DOI] [PubMed] [Google Scholar]
  21. Lichey J., Reschofski I., Dissmann T., Priesnitz M., Hoffmann M., Lode H. Fibrin degradation product D-dimer in the diagnosis of pulmonary embolism. Klin Wochenschr. 1991 Aug 16;69(12):522–526. doi: 10.1007/BF01649289. [DOI] [PubMed] [Google Scholar]
  22. Lindahl T. L., Lundahl T. H., Ranby M., Fransson S. G. Clinical evaluation of a diagnostic strategy for deep venous thrombosis with exclusion by low plasma levels of fibrin degradation product D-dimer. Scand J Clin Lab Invest. 1998 Jul;58(4):307–316. doi: 10.1080/00365519850186481. [DOI] [PubMed] [Google Scholar]
  23. Mauron T., Baumgartner I., Z'Brun A., Demarmels Biasiutti F., Redondo M., Do D. D., Lämmle B., Wuillemin W. A. SimpliRED D-dimer assay: comparability of capillary and citrated venous whole blood, between-assay variability, and performance of the test for exclusion of deep vein thrombosis in symptomatic outpatients. Thromb Haemost. 1998 Jun;79(6):1217–1219. [PubMed] [Google Scholar]
  24. Oger E., Leroyer C., Bressollette L., Nonent M., Le Moigne E., Bizais Y., Amiral J., Grimaux M., Clavier J., Ill P. Evaluation of a new, rapid, and quantitative D-Dimer test in patients with suspected pulmonary embolism. Am J Respir Crit Care Med. 1998 Jul;158(1):65–70. doi: 10.1164/ajrccm.158.1.9710058. [DOI] [PubMed] [Google Scholar]
  25. Pallela V. R., Thakur M. L., Consigny P. M., Rao P. S., Vasileva-Belnikolavska D., Shi R. Imaging thromboembolism with Tc-99m-labeled thrombospondin receptor analogs TP-1201 and TP-1300. Thromb Res. 1999 Feb 15;93(4):191–202. doi: 10.1016/s0049-3848(98)00180-7. [DOI] [PubMed] [Google Scholar]
  26. Piccioli A., Prandoni P., Goldhaber S. Z. Epidemiologic characteristics, management, and outcome of deep venous thrombosis in a tertiary-care hospital: the Brigham and Women's Hospital DVT registry. Am Heart J. 1996 Nov;132(5):1010–1014. doi: 10.1016/s0002-8703(96)90014-9. [DOI] [PubMed] [Google Scholar]
  27. Stein P. D., Athanasoulis C., Alavi A., Greenspan R. H., Hales C. A., Saltzman H. A., Vreim C. E., Terrin M. L., Weg J. G. Complications and validity of pulmonary angiography in acute pulmonary embolism. Circulation. 1992 Feb;85(2):462–468. doi: 10.1161/01.cir.85.2.462. [DOI] [PubMed] [Google Scholar]
  28. Stein P. D., Henry J. W. Clinical characteristics of patients with acute pulmonary embolism stratified according to their presenting syndromes. Chest. 1997 Oct;112(4):974–979. doi: 10.1378/chest.112.4.974. [DOI] [PubMed] [Google Scholar]
  29. Stein P. D., Henry J. W. Prevalence of acute pulmonary embolism among patients in a general hospital and at autopsy. Chest. 1995 Oct;108(4):978–981. doi: 10.1378/chest.108.4.978. [DOI] [PubMed] [Google Scholar]
  30. Stevanovic G., Tucakovic G., Dotlic R., Kanjuh V. Correlation of clinical diagnoses with autopsy findings: a retrospective study of 2,145 consecutive autopsies. Hum Pathol. 1986 Dec;17(12):1225–1230. doi: 10.1016/s0046-8177(86)80564-0. [DOI] [PubMed] [Google Scholar]
  31. Turkstra F., Kuijer P. M., van Beek E. J., Brandjes D. P., ten Cate J. W., Büller H. R. Diagnostic utility of ultrasonography of leg veins in patients suspected of having pulmonary embolism. Ann Intern Med. 1997 May 15;126(10):775–781. doi: 10.7326/0003-4819-126-10-199705150-00005. [DOI] [PubMed] [Google Scholar]
  32. Turkstra F., van Beek E. J., ten Cate J. W., Büller H. R. Reliable rapid blood test for the exclusion of venous thromboembolism in symptomatic outpatients. Thromb Haemost. 1996 Jul;76(1):9–11. [PubMed] [Google Scholar]
  33. Veitl M., Hamwi A., Kurtaran A., Virgolini I., Vukovich T. Comparison of four rapid D-Dimer tests for diagnosis of pulmonary embolism. Thromb Res. 1996 Jun 1;82(5):399–407. doi: 10.1016/0049-3848(96)00089-8. [DOI] [PubMed] [Google Scholar]
  34. Wells P. S., Brill-Edwards P., Stevens P., Panju A., Patel A., Douketis J., Massicotte M. P., Hirsh J., Weitz J. I., Kearon C. A novel and rapid whole-blood assay for D-dimer in patients with clinically suspected deep vein thrombosis. Circulation. 1995 Apr 15;91(8):2184–2187. doi: 10.1161/01.cir.91.8.2184. [DOI] [PubMed] [Google Scholar]
  35. Wells P. S., Ginsberg J. S., Anderson D. R., Kearon C., Gent M., Turpie A. G., Bormanis J., Weitz J., Chamberlain M., Bowie D. Use of a clinical model for safe management of patients with suspected pulmonary embolism. Ann Intern Med. 1998 Dec 15;129(12):997–1005. doi: 10.7326/0003-4819-129-12-199812150-00002. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Clinical Pathology are provided here courtesy of BMJ Publishing Group

RESOURCES