Skip to main content
Journal of Neurology, Neurosurgery, and Psychiatry logoLink to Journal of Neurology, Neurosurgery, and Psychiatry
. 2003 May;74(5):561–565. doi: 10.1136/jnnp.74.5.561

Intraventricular monitoring for temporal lobe epilepsy: report on technique and initial results in eight patients

J Song 1, B Abou-Khalil 1, P Konrad 1
PMCID: PMC1738458  PMID: 12700290

Abstract

Objective and importance: Resective surgery is an effective treatment for refractory temporal lobe epilepsy. In difficult cases, invasive monitoring may be needed to precisely lateralise and localise seizure foci of mesial temporal origin. The authors present a modified technique for image guided, endoscopic placement of an intraventricular electrode array (IVE) that abuts the amygdalo-hippocampal complex.

Methods: Eight patients with suspected mesial temporal lobe epilepsy had placement of an IVE in conjunction with other invasive electrodes. Seven of these patients also had subdural grid or strip electrodes and four had foramen ovale electrodes. Frameless image guidance was used to place a custom 10-contact depth electrode through a rigid neuroendoscope within the atrium of the lateral ventricle. Once proper orientation towards the temporal horn was confirmed, the IVE array was advanced into the temporal horn to the temporal tip. The endoscope was removed and electrode placement was confirmed through an intraoperative lateral skull radiograph and on visual inspection at the time of resection in two cases.

Results: The IVE was crucial for localisation in one patient and helped localisation in four others. Surgery was offered to seven patients. The only serious complication of IVE placement was a thalamic contusion presumably from an errant electrode tip. One electrode was inadvertently placed into the frontal horn. There were no deaths and no permanent morbidity associated with the procedure.

Conclusion: Endoscopically placed temporal horn, intraventricular electrodes provide an alternative to transcortical depth electrode placement. The technique hopefully can avoid complications associated with multiple depth electrode placements, especially when bilateral amygdalo-hippocampal electrical recordings are desired, although there may be a steep learning curve.

Full Text

The Full Text of this article is available as a PDF (194.3 KB).

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Behrens E., Zentner J., van Roost D., Hufnagel A., Elger C. E., Schramm J. Subdural and depth electrodes in the presurgical evaluation of epilepsy. Acta Neurochir (Wien) 1994;128(1-4):84–87. doi: 10.1007/BF01400656. [DOI] [PubMed] [Google Scholar]
  2. Blatt D. R., Roper S. N., Friedman W. A. Invasive monitoring of limbic epilepsy using stereotactic depth and subdural strip electrodes: surgical technique. Surg Neurol. 1997 Jul;48(1):74–79. doi: 10.1016/s0090-3019(96)00277-7. [DOI] [PubMed] [Google Scholar]
  3. Blume W. T., Parrent A. G., Kaibara M. Stereotactic amygdalohippocampotomy and mesial temporal spikes. Epilepsia. 1997 Aug;38(8):930–936. doi: 10.1111/j.1528-1157.1997.tb01259.x. [DOI] [PubMed] [Google Scholar]
  4. Cahan L. D., Sutherling W., McCullough M. A., Rausch R., Engel J., Jr, Crandall P. H. Review of the 20-year UCLA experience with surgery for epilepsy. Cleve Clin Q. 1984 Summer;51(2):313–318. doi: 10.3949/ccjm.51.2.313. [DOI] [PubMed] [Google Scholar]
  5. McBride M. C., Binnie C. D., Janota I., Polkey C. E. Predictive value of intraoperative electrocorticograms in resective epilepsy surgery. Ann Neurol. 1991 Oct;30(4):526–532. doi: 10.1002/ana.410300404. [DOI] [PubMed] [Google Scholar]
  6. Nakase H., Ohnishi H., Touho H., Karasawa J., Yamamoto S., Shimizu K. An intra-arterial electrode for intracranial electro-encephalogram recordings. Acta Neurochir (Wien) 1995;136(1-2):103–105. doi: 10.1007/BF01411445. [DOI] [PubMed] [Google Scholar]
  7. Polkey C. E., Binnie C. D., Janota I. Acute hippocampal recording and pathology at temporal lobe resection and amygdalo-hippocampectomy for epilepsy. J Neurol Neurosurg Psychiatry. 1989 Sep;52(9):1050–1057. doi: 10.1136/jnnp.52.9.1050. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Ross D. A., Brunberg J. A., Drury I., Henry T. R. Intracerebral depth electrode monitoring in partial epilepsy: the morbidity and efficacy of placement using magnetic resonance image-guided stereotactic surgery. Neurosurgery. 1996 Aug;39(2):327–334. doi: 10.1097/00006123-199608000-00018. [DOI] [PubMed] [Google Scholar]
  9. Spencer S. S., Spencer D. D., Williamson P. D., Mattson R. Combined depth and subdural electrode investigation in uncontrolled epilepsy. Neurology. 1990 Jan;40(1):74–79. doi: 10.1212/wnl.40.1.74. [DOI] [PubMed] [Google Scholar]

Articles from Journal of Neurology, Neurosurgery, and Psychiatry are provided here courtesy of BMJ Publishing Group

RESOURCES