Skip to main content
Occupational and Environmental Medicine logoLink to Occupational and Environmental Medicine
. 2000 Feb;57(2):140–142. doi: 10.1136/oem.57.2.140

Half life of chromium in serum and urine in a former plasma cutter of stainless steel

R Petersen 1, J F Thomsen 1, N K Jorgensen 1, S Mikkelsen 1
PMCID: PMC1739905  PMID: 10711283

Abstract

For 8 years chromium in serum and urine has been followed up in a former plasma cutter of stainless steel who was exposed to airborne dust and fumes containing chromium during this work. After the first examination for serum chromium the exposure ended. Serum chromium concentration has been measured seven times during the period and was initially very high and has subsequently dropped slowly. The half life was 40 months in serum. Urinary chromium has been measured five times. The half life was 129 months in urine. The study shows that exposure to airborne dust and fumes containing chromium may cause accumulation of chromium in the body, and that when exposure ends, elimination of chromium is very slow. Previous studies suggest that chromium mainly accumulates in the lungs.


Keywords: chromium half life; plasma cutting; stainless steel

Full Text

The Full Text of this article is available as a PDF (105.6 KB).


Articles from Occupational and Environmental Medicine are provided here courtesy of BMJ Publishing Group

RESOURCES