Aims: To assess hazards associated with exposure to dust in the London Underground railway and to provide an informed opinion on the risks to workers and the travelling public of exposure to tunnel dust.

Methods: Concentrations of dust, as mass (PM2.5) and particle number, were measured at different underground stations and in train cabs; its size and composition were analysed; likely maximal exposures of staff and passengers were estimated; and in vitro toxicological testing of sample dusts in comparison with other dusts was performed.

Results: Concentrations on station platforms were 270–480 µg/m3 PM2.5 and 14 000–29 000 particles/cm3. Cab concentrations over a shift averaged 130–200 µg/m3 and 17 000–23 000 particles/cm3. The dust comprised by mass approximately 67% iron oxide, 1–2% quartz, and traces of other metals, the residue being volatile matter. The finest particles are drawn underground from the surface while the coarser dust is generated by interaction of brakes, wheels, and rails. Taking account of durations of exposure, drivers and station staff would have maximum exposures of about 200 µg/m3 over eight hours; the occupational exposure standard for welding fume, as iron oxide, is 5 mg/m3 over an eight hour shift. Toxicology showed the dust to have cytotoxic and inflammatory potential at high doses, consistent with its composition largely of iron oxide.

Discussion: It is unjustifiable to compare PM2.5 exposure underground with that on the surface, since the adverse effects of iron oxide and combustion generated particles differ. Concentrations of ultrafine particles are lower and of coarser (PM2.5) particles higher underground than on the surface. The concentrations underground are well below allowable workplace concentrations for iron oxide and unlikely to represent a significant cumulative risk to the health of workers or commuters.

Full Text

The Full Text of this article is available as a PDF (203.0 KB).

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Adams H. S., Nieuwenhuijsen M. J., Colvile R. N., McMullen M. A., Khandelwal P. Fine particle (PM2.5) personal exposure levels in transport microenvironments, London, UK. Sci Total Environ. 2001 Nov 12;279(1-3):29–44. doi: 10.1016/s0048-9697(01)00723-9. [DOI] [PubMed] [Google Scholar]
  2. Chillrud Steven N., Epstein David, Ross James M., Sax Sonja N., Pederson Dee, Spengler John D., Kinney Patrick L. Elevated airborne exposures of teenagers to manganese, chromium, and iron from steel dust and New York City's subway system. Environ Sci Technol. 2004 Feb 1;38(3):732–737. doi: 10.1021/es034734y. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Doherty M. J., Healy M., Richardson S. G., Fisher N. C. Total body iron overload in welder's siderosis. Occup Environ Med. 2004 Jan;61(1):82–85. [PMC free article] [PubMed] [Google Scholar]
  4. Driscoll K. E. Macrophage inflammatory proteins: biology and role in pulmonary inflammation. Exp Lung Res. 1994 Nov-Dec;20(6):473–490. doi: 10.3109/01902149409031733. [DOI] [PubMed] [Google Scholar]
  5. Ghio A. J., Carter J. D., Richards J. H., Brighton L. E., Lay J. C., Devlin R. B. Disruption of normal iron homeostasis after bronchial instillation of an iron-containing particle. Am J Physiol. 1998 Mar;274(3 Pt 1):L396–L403. doi: 10.1152/ajplung.1998.274.3.L396. [DOI] [PubMed] [Google Scholar]
  6. Gilmour P. S., Beswick P. H., Brown D. M., Donaldson K. Detection of surface free radical activity of respirable industrial fibres using supercoiled phi X174 RF1 plasmid DNA. Carcinogenesis. 1995 Dec;16(12):2973–2979. doi: 10.1093/carcin/16.12.2973. [DOI] [PubMed] [Google Scholar]
  7. Gilmour P. S., Brown D. M., Lindsay T. G., Beswick P. H., MacNee W., Donaldson K. Adverse health effects of PM10 particles: involvement of iron in generation of hydroxyl radical. Occup Environ Med. 1996 Dec;53(12):817–822. doi: 10.1136/oem.53.12.817. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Lieber M., Smith B., Szakal A., Nelson-Rees W., Todaro G. A continuous tumor-cell line from a human lung carcinoma with properties of type II alveolar epithelial cells. Int J Cancer. 1976 Jan 15;17(1):62–70. doi: 10.1002/ijc.2910170110. [DOI] [PubMed] [Google Scholar]
  9. McNeilly Jane D., Heal Mathew R., Beverland Iain J., Howe Alan, Gibson Mark D., Hibbs Leon R., MacNee William, Donaldson Ken. Soluble transition metals cause the pro-inflammatory effects of welding fumes in vitro. Toxicol Appl Pharmacol. 2004 Apr 1;196(1):95–107. doi: 10.1016/j.taap.2003.11.021. [DOI] [PubMed] [Google Scholar]
  10. Palmer Keith T., Poole Jason, Ayres Jon G., Mann Jonathan, Burge P. Sherwood, Coggon David. Exposure to metal fume and infectious pneumonia. Am J Epidemiol. 2003 Feb 1;157(3):227–233. doi: 10.1093/aje/kwf188. [DOI] [PubMed] [Google Scholar]
  11. Pfeifer G. D., Harrison R. M., Lynam D. R. Personal exposures to airborne metals in London taxi drivers and office workers in 1995 and 1996. Sci Total Environ. 1999 Sep 1;235(1-3):253–260. doi: 10.1016/s0048-9697(99)00201-6. [DOI] [PubMed] [Google Scholar]
  12. Schins Roel P. F., Lightbody Janet H., Borm Paul J. A., Shi Tingming, Donaldson Ken, Stone Vicki. Inflammatory effects of coarse and fine particulate matter in relation to chemical and biological constituents. Toxicol Appl Pharmacol. 2004 Feb 15;195(1):1–11. doi: 10.1016/j.taap.2003.10.002. [DOI] [PubMed] [Google Scholar]

Articles from Occupational and Environmental Medicine are provided here courtesy of BMJ Publishing Group

RESOURCES