Abstract
BACKGROUND—The gold standard diagnostic test for obstructive sleep apnoea (OSA) is overnight polysomnography (PSG) which is costly in terms of time and money. Consequently, a number of alternatives to PSG have been proposed. Oximetry is appealing because of its widespread availability and ease of application. The diagnostic performance of an automated analysis algorithm based on falls and recovery of digitally recorded oxygen saturation was compared with PSG. METHODS—Two hundred and forty six patients with suspected OSA were randomly selected for PSG and automated off line analysis of the digitally recorded oximeter signal. RESULTS—The PSG derived apnoea hypopnoea index (AHI) and oximeter derived respiratory disturbance index (RDI) were highly correlated (R = 0.97). The mean (2SD) of the differences between AHI and RDI was 2.18 (12.34)/h. The sensitivity and specificity of the algorithm depended on the AHI and RDI criteria selected for OSA case designation. Using case designation criteria of 15/h for AHI and RDI, the sensitivity and specificity were 98% and 88%, respectively. If the PSG derived AHI included EEG based arousals as part of the hypopnoea definition, the mean (2SD) of the differences between RDI and AHI was -0.12 (15.62)/h and the sensitivity and specificity profile did not change significantly. CONCLUSIONS—In a population of patients suspected of having OSA, off line automated analysis of the oximetry signal provides a close estimate of AHI as well as excellent diagnostic sensitivity and specificity for OSA.
Full Text
The Full Text of this article is available as a PDF (162.1 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Ancoli-Israel S., Kripke D. F., Mason W., Messin S. Comparisons of home sleep recordings and polysomnograms in older adults with sleep disorders. Sleep. 1981 Sep;4(3):283–291. doi: 10.1093/sleep/4.3.283. [DOI] [PubMed] [Google Scholar]
- Bland J. M., Altman D. G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986 Feb 8;1(8476):307–310. [PubMed] [Google Scholar]
- Cooper B. G., Veale D., Griffiths C. J., Gibson G. J. Value of nocturnal oxygen saturation as a screening test for sleep apnoea. Thorax. 1991 Aug;46(8):586–588. doi: 10.1136/thx.46.8.586. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Douglas N. J., Thomas S., Jan M. A. Clinical value of polysomnography. Lancet. 1992 Feb 8;339(8789):347–350. doi: 10.1016/0140-6736(92)91660-z. [DOI] [PubMed] [Google Scholar]
- Farney R. J., Walker L. E., Jensen R. L., Walker J. M. Ear oximetry to detect apnea and differentiate rapid eye movement (REM) and non-REM (NREM) sleep. Screening for the sleep apnea syndrome. Chest. 1986 Apr;89(4):533–539. doi: 10.1378/chest.89.4.533. [DOI] [PubMed] [Google Scholar]
- Gould G. A., Whyte K. F., Rhind G. B., Airlie M. A., Catterall J. R., Shapiro C. M., Douglas N. J. The sleep hypopnea syndrome. Am Rev Respir Dis. 1988 Apr;137(4):895–898. doi: 10.1164/ajrccm/137.4.895. [DOI] [PubMed] [Google Scholar]
- Gyulay S., Olson L. G., Hensley M. J., King M. T., Allen K. M., Saunders N. A. A comparison of clinical assessment and home oximetry in the diagnosis of obstructive sleep apnea. Am Rev Respir Dis. 1993 Jan;147(1):50–53. doi: 10.1164/ajrccm/147.1.50. [DOI] [PubMed] [Google Scholar]
- Hla K. M., Young T. B., Bidwell T., Palta M., Skatrud J. B., Dempsey J. Sleep apnea and hypertension. A population-based study. Ann Intern Med. 1994 Mar 1;120(5):382–388. doi: 10.7326/0003-4819-120-5-199403010-00005. [DOI] [PubMed] [Google Scholar]
- Issa F. G., Morrison D., Hadjuk E., Iyer A., Feroah T., Remmers J. E. Digital monitoring of sleep-disordered breathing using snoring sound and arterial oxygen saturation. Am Rev Respir Dis. 1993 Oct;148(4 Pt 1):1023–1029. doi: 10.1164/ajrccm/148.4_Pt_1.1023. [DOI] [PubMed] [Google Scholar]
- Orr W. C., Eiken T., Pegram V., Jones R., Rundell O. H. A laboratory validation study of a portable system for remote recording of sleep-related respiratory disorders. Chest. 1994 Jan;105(1):160–162. doi: 10.1378/chest.105.1.160. [DOI] [PubMed] [Google Scholar]
- Redline S., Tosteson T., Boucher M. A., Millman R. P. Measurement of sleep-related breathing disturbances in epidemiologic studies. Assessment of the validity and reproducibility of a portable monitoring device. Chest. 1991 Nov;100(5):1281–1286. doi: 10.1378/chest.100.5.1281. [DOI] [PubMed] [Google Scholar]
- Stoohs R., Guilleminault C. MESAM 4: an ambulatory device for the detection of patients at risk for obstructive sleep apnea syndrome (OSAS). Chest. 1992 May;101(5):1221–1227. doi: 10.1378/chest.101.5.1221. [DOI] [PubMed] [Google Scholar]
- Sériès F., Marc I., Cormier Y., La Forge J. Utility of nocturnal home oximetry for case finding in patients with suspected sleep apnea hypopnea syndrome. Ann Intern Med. 1993 Sep 15;119(6):449–453. doi: 10.7326/0003-4819-119-6-199309150-00001. [DOI] [PubMed] [Google Scholar]
- Tsai W. H., Flemons W. W., Whitelaw W. A., Remmers J. E. A comparison of apnea-hypopnea indices derived from different definitions of hypopnea. Am J Respir Crit Care Med. 1999 Jan;159(1):43–48. doi: 10.1164/ajrccm.159.1.9709017. [DOI] [PubMed] [Google Scholar]
- White D. P., Gibb T. J., Wall J. M., Westbrook P. R. Assessment of accuracy and analysis time of a novel device to monitor sleep and breathing in the home. Sleep. 1995 Feb;18(2):115–126. doi: 10.1093/sleep/18.2.115. [DOI] [PubMed] [Google Scholar]
- Williams A. J., Yu G., Santiago S., Stein M. Screening for sleep apnea using pulse oximetry and a clinical score. Chest. 1991 Sep;100(3):631–635. doi: 10.1378/chest.100.3.631. [DOI] [PubMed] [Google Scholar]
- Young T., Palta M., Dempsey J., Skatrud J., Weber S., Badr S. The occurrence of sleep-disordered breathing among middle-aged adults. N Engl J Med. 1993 Apr 29;328(17):1230–1235. doi: 10.1056/NEJM199304293281704. [DOI] [PubMed] [Google Scholar]