OBJECTIVE—To determine the best method of preparing synovial fluid specimens for use in quality assurance (QA) surveys designed to assess accuracy of crystal identification.
METHODS—A previously published method (A) was compared with a new method (B) in the setting of a QA survey. Ten Australian, one New Zealand, and one Hong Kong hospital laboratories took part in the survey. Each laboratory examined six different synovial fluid specimens prepared using method A (first round) and a separate six specimens using method B (second round). In method A, a drop of synovial fluid on a glass slide was surrounded by a rim of Ultramount, sealed with a coverslip, and distributed. The participating laboratory did not need to perform any processing of the specimen before examination. In method B, a capillary tip was filled with synovial fluid, heat sealed, and distributed. The fluid was expelled onto a glass slide in preparation for examination after arrival in the participating laboratory.
RESULTS—Using method A 36 of 71 (51%) of the specimens were rated as satisfactory, compared with 53 of 61 (87%) of the specimens using method B (Fisher's exact test, p<0.001).
CONCLUSIONS—An improved method of preparation of synovial fluid specimens for QA surveys is described. Using the new method it is feasible to perform a synovial fluid QA survey covering a large area (Australasia).