Abstract
OBJECTIVES: To assess the magnitude of error in pulmonary function measurements introduced by variation in spirometer temperature under field conditions. In a large scale epidemiological study of school children, the influence was investigated of spirometer temperature on forced expiratory volume in 1 second (FEV1) measured with dry rolling seal volumetric spirometers and conventional body temperature, pressure, and saturation (BTPS) corrections. METHODS: Linear regression analyses were performed on data from 995 test-retest pairs on 851 different children, with 1-110 days between test and retest, and spirometer temperature differences between -13 degrees C and +9 degrees C. RESULTS: After adjusting for effects of growth (test-retest intervals) and circadian variation (changes in times of testing), differences in standard BTPS corrected FEV1 showed significant (p < 0.05) dependence on differences in spirometer temperature between tests (-0.24%/degree C). CONCLUSIONS: When spirometer temperatures vary widely, standard BTPS correction does not fully adjust for gas contraction. To improve accuracy of volume measurements in epidemiological studies, additional correction for variation in spirometer temperature should be considered.
Full Text
The Full Text of this article is available as a PDF (64.1 KB).
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Hankinson J. L., Castellan R. M., Kinsley K. B., Keimig D. G. Effect of spirometer temperature on measurement of FEV1 shift changes. J Occup Med. 1986 Dec;28(12):1222–1225. [PubMed] [Google Scholar]
- Hankinson J. L., Viola J. O. Dynamic BTPS correction factors for spirometric data. J Appl Physiol Respir Environ Exerc Physiol. 1983 Oct;55(4):1354–1360. doi: 10.1152/jappl.1983.55.4.1354. [DOI] [PubMed] [Google Scholar]
- Linn W. S., Solomon J. C., Gong H., Jr, Avol E. L., Navidi W. C., Peters J. M. Standardization of multiple spirometers at widely separated times and places. Am J Respir Crit Care Med. 1996 Apr;153(4 Pt 1):1309–1313. doi: 10.1164/ajrccm.153.4.8616559. [DOI] [PubMed] [Google Scholar]
- Linn W. S., Solomon J. C., Gong H., Jr, Avol E. L., Peters J. M. Temperature standardization of multiple spirometers. J Occup Environ Med. 1998 Feb;40(2):148–152. doi: 10.1097/00043764-199802000-00011. [DOI] [PubMed] [Google Scholar]
- Perks W. H., Sopwith T., Brown D., Jones C. H., Green M. Effects of temperature on Vitalograph spirometer readings. Thorax. 1983 Aug;38(8):592–594. doi: 10.1136/thx.38.8.592. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pincock A. C., Miller M. R. The effect of temperature on recording spirograms. Am Rev Respir Dis. 1983 Nov;128(5):894–898. doi: 10.1164/arrd.1983.128.5.894. [DOI] [PubMed] [Google Scholar]
- Quanjer P. H., Tammeling G. J., Cotes J. E., Pedersen O. F., Peslin R., Yernault J. C. Lung volumes and forced ventilatory flows. Report Working Party Standardization of Lung Function Tests, European Community for Steel and Coal. Official Statement of the European Respiratory Society. Eur Respir J Suppl. 1993 Mar;16:5–40. [PubMed] [Google Scholar]