Abstract
To assess risk factors associated with the contamination of the domestic environment by legionellae, 211 houses in the Quebec City area were randomly selected and water samples were collected from the hot water tank, the shower heads, and the most frequently used faucet. After centrifugation, concentrated samples were seeded in triplicate on BCYE and GPV media. Data on the characteristics of the hot water system and plumbing in the house and on the personal habits of the occupants were collected for each house. Among these 211 houses, hot water was provided by either an oil or gas heater in 33 and by an electric heater in 178. Legionellae were isolated from none of the samples from houses with oil or gas heaters and from 39% (69 of 178) of those with electric water heaters (P less than 0.0001). This association remained highly significant after control for water temperature and other variables in a stratified analysis. In the 178 houses with an electric heater, 12% of the faucets, 15% of the shower heads, and 37% of the water heaters were contaminated. Legionella pneumophila serogroups 2 and 4 were the most frequently isolated strains. Logistic regression showed that factors associated with electric water heater contamination were (i) location of the house in older districts of the city (P less than 0.0001), (ii) old age of the water heater (P = 0.003), and (iii) low water temperature (P = 0.05). Contamination of the water heater was the only factor significantly associated with the contamination of peripheral outlets (P less than 0.0001).(ABSTRACT TRUNCATED AT 250 WORDS)
Full text
PDFSelected References
These references are in PubMed. This may not be the complete list of references from this article.
- Bartlett C. L., Kurtz J. B., Hutchison J. G., Turner G. C., Wright A. E. Legionella in hospital and hotel water supplies. Lancet. 1983 Dec 3;2(8362):1315–1315. doi: 10.1016/s0140-6736(83)91203-5. [DOI] [PubMed] [Google Scholar]
- Bornstein N., Vieilly C., Nowicki M., Paucod J. C., Fleurette J. Epidemiological evidence of legionellosis transmission through domestic hot water supply systems and possibilities of control. Isr J Med Sci. 1986 Sep;22(9):655–661. [PubMed] [Google Scholar]
- Breiman R. F., Fields B. S., Sanden G. N., Volmer L., Meier A., Spika J. S. Association of shower use with Legionnaires' disease. Possible role of amoebae. JAMA. 1990 Jun 6;263(21):2924–2926. [PubMed] [Google Scholar]
- Castellani Pastoris M., Viganò E. F., Passi C. A family cluster of Legionella pneumophila infections. Scand J Infect Dis. 1988;20(5):489–493. doi: 10.3109/00365548809032496. [DOI] [PubMed] [Google Scholar]
- Ciesielski C. A., Blaser M. J., Wang W. L. Role of stagnation and obstruction of water flow in isolation of Legionella pneumophila from hospital plumbing. Appl Environ Microbiol. 1984 Nov;48(5):984–987. doi: 10.1128/aem.48.5.984-987.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Dennis P. J., Taylor J. A., Fitzgeorge R. B., Bartlett C. L., Barrow G. I. Legionella pneumophila in water plumbing systems. Lancet. 1982 Apr 24;1(8278):949–951. doi: 10.1016/s0140-6736(82)91944-4. [DOI] [PubMed] [Google Scholar]
- Dennis P. J., Wright A. E., Rutter D. A., Death J. E., Jones B. P. Legionella pneumophila in aerosols from shower baths. J Hyg (Lond) 1984 Oct;93(2):349–353. doi: 10.1017/s0022172400064901. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Desplaces N., Nahapetian K., Dournon E. Inventaire des Legionella dans l'environnement parisien. Implications pratiques. Presse Med. 1984 Sep 15;13(31):1875–1879. [PubMed] [Google Scholar]
- Dondero T. J., Jr, Rendtorff R. C., Mallison G. F., Weeks R. M., Levy J. S., Wong E. W., Schaffner W. An outbreak of Legionnaires' disease associated with a contaminated air-conditioning cooling tower. N Engl J Med. 1980 Feb 14;302(7):365–370. doi: 10.1056/NEJM198002143020703. [DOI] [PubMed] [Google Scholar]
- Dutka B. J., Walsh K., Ewan P., El-Shaarawi A., Tobin R. S. Incidence of Legionella organisms in selected Ontario (Canada) cities. Sci Total Environ. 1984 Nov;39(3):237–249. doi: 10.1016/0048-9697(84)90081-0. [DOI] [PubMed] [Google Scholar]
- Fliermans C. B., Cherry W. B., Orrison L. H., Smith S. J., Tison D. L., Pope D. H. Ecological distribution of Legionella pneumophila. Appl Environ Microbiol. 1981 Jan;41(1):9–16. doi: 10.1128/aem.41.1.9-16.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Fraser D. W., Tsai T. R., Orenstein W., Parkin W. E., Beecham H. J., Sharrar R. G., Harris J., Mallison G. F., Martin S. M., McDade J. E. Legionnaires' disease: description of an epidemic of pneumonia. N Engl J Med. 1977 Dec 1;297(22):1189–1197. doi: 10.1056/NEJM197712012972201. [DOI] [PubMed] [Google Scholar]
- Glick T. H., Gregg M. B., Berman B., Mallison G., Rhodes W. W., Jr, Kassanoff I. Pontiac fever. An epidemic of unknown etiology in a health department: I. Clinical and epidemiologic aspects. Am J Epidemiol. 1978 Feb;107(2):149–160. doi: 10.1093/oxfordjournals.aje.a112517. [DOI] [PubMed] [Google Scholar]
- Gosting L. H., Cabrian K., Sturge J. C., Goldstein L. C. Identification of a species-specific antigen in Legionella pneumophila by a monoclonal antibody. J Clin Microbiol. 1984 Dec;20(6):1031–1035. doi: 10.1128/jcm.20.6.1031-1035.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Groothuis D. G., Veenendaal H. R., Dijkstra H. L. Influence of temperature on the number of Legionella pneumophila in hot water systems. J Appl Bacteriol. 1985 Dec;59(6):529–536. doi: 10.1111/j.1365-2672.1985.tb03356.x. [DOI] [PubMed] [Google Scholar]
- Helms C. M., Massanari R. M., Zeitler R., Streed S., Gilchrist M. J., Hall N., Hausler W. J., Jr, Sywassink J., Johnson W., Wintermeyer L. Legionnaires' disease associated with a hospital water system: a cluster of 24 nosocomial cases. Ann Intern Med. 1983 Aug;99(2):172–178. doi: 10.7326/0003-4819-99-2-172. [DOI] [PubMed] [Google Scholar]
- Hsu S. C., Martin R., Wentworth B. B. Isolation of Legionella species from drinking water. Appl Environ Microbiol. 1984 Oct;48(4):830–832. doi: 10.1128/aem.48.4.830-832.1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Joly J. R., Boissinot M., Duchaine J., Duval M., Rafrafi J., Ramsay D., Letarte R. Ecological distribution of Legionellaceae in the Quebec city area. Can J Microbiol. 1984 Jan;30(1):63–67. doi: 10.1139/m84-011. [DOI] [PubMed] [Google Scholar]
- Joly J. R., Winn W. C. Correlation of subtypes of Legionella pneumophila defined by monoclonal antibodies with epidemiological classification of cases and environmental sources. J Infect Dis. 1984 Nov;150(5):667–671. doi: 10.1093/infdis/150.5.667. [DOI] [PubMed] [Google Scholar]
- Joly J. Legionella and domestic water heaters in the Quebec City area. Can Med Assoc J. 1985 Jan 15;132(2):160–160. [PMC free article] [PubMed] [Google Scholar]
- Lee T. C., Stout J. E., Yu V. L. Factors predisposing to Legionella pneumophila colonization in residential water systems. Arch Environ Health. 1988 Jan-Feb;43(1):59–62. doi: 10.1080/00039896.1988.9934375. [DOI] [PubMed] [Google Scholar]
- MANTEL N., HAENSZEL W. Statistical aspects of the analysis of data from retrospective studies of disease. J Natl Cancer Inst. 1959 Apr;22(4):719–748. [PubMed] [Google Scholar]
- Morris G. K., Patton C. M., Feeley J. C., Johnson S. E., Gorman G., Martin W. T., Skaliy P., Mallison G. F., Politi B. D., Mackel D. C. Isolation of the Legionnaires' disease bacterium from environmental samples. Ann Intern Med. 1979 Apr;90(4):664–666. doi: 10.7326/0003-4819-90-4-664. [DOI] [PubMed] [Google Scholar]
- Ortiz-Roque C. M., Hazen T. C. Abundance and distribution of Legionellaceae in Puerto Rican waters. Appl Environ Microbiol. 1987 Sep;53(9):2231–2236. doi: 10.1128/aem.53.9.2231-2236.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Pasculle A. W., Feeley J. C., Gibson R. J., Cordes L. G., Myerowitz R. L., Patton C. M., Gorman G. W., Carmack C. L., Ezzell J. W., Dowling J. N. Pittsburgh pneumonia agent: direct isolation from human lung tissue. J Infect Dis. 1980 Jun;141(6):727–732. doi: 10.1093/infdis/141.6.727. [DOI] [PubMed] [Google Scholar]
- Politi B. D., Fraser D. W., Mallison G. F., Mohatt J. V., Morris G. K., Patton C. M., Feeley J. C., Telle R. D., Bennett J. V. A major focus of Legionnaires' disease in Bloomington, Indiana. Ann Intern Med. 1979 Apr;90(4):587–591. doi: 10.7326/0003-4819-90-4-587. [DOI] [PubMed] [Google Scholar]
- Rowbotham T. J. Preliminary report on the pathogenicity of Legionella pneumophila for freshwater and soil amoebae. J Clin Pathol. 1980 Dec;33(12):1179–1183. doi: 10.1136/jcp.33.12.1179. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ruf B., Schürmann D., Horbach I., Seidel K., Pohle H. D. Nosocomial legionella pneumonia: demonstration of potable water as the source of infection. Epidemiol Infect. 1988 Dec;101(3):647–654. doi: 10.1017/s0950268800029526. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Schlech W. F., 3rd, Gorman G. W., Payne M. C., Broome C. V. Legionnaires' disease in the Caribbean. An outbreak associated with a resort hotel. Arch Intern Med. 1985 Nov;145(11):2076–2079. [PubMed] [Google Scholar]
- Schofield G. M., Locci R. Colonization of components of a model hot water system by Legionella pneumophila. J Appl Bacteriol. 1985 Feb;58(2):151–162. doi: 10.1111/j.1365-2672.1985.tb01442.x. [DOI] [PubMed] [Google Scholar]
- States S. J., Conley L. F., Kuchta J. M., Oleck B. M., Lipovich M. J., Wolford R. S., Wadowsky R. M., McNamara A. M., Sykora J. L., Keleti G. Survival and multiplication of Legionella pneumophila in municipal drinking water systems. Appl Environ Microbiol. 1987 May;53(5):979–986. doi: 10.1128/aem.53.5.979-986.1987. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Stout J. E., Yu V. L., Best M. G. Ecology of Legionella pneumophila within water distribution systems. Appl Environ Microbiol. 1985 Jan;49(1):221–228. doi: 10.1128/aem.49.1.221-228.1985. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Stout J. E., Yu V. L., Muraca P. Legionnaires' disease acquired within the homes of two patients. Link to the home water supply. JAMA. 1987 Mar 6;257(9):1215–1217. [PubMed] [Google Scholar]
- Stout J., Yu V. L., Vickers R. M., Zuravleff J., Best M., Brown A., Yee R. B., Wadowsky R. Ubiquitousness of Legionella pneumophila in the water supply of a hospital with endemic Legionnaires' disease. N Engl J Med. 1982 Feb 25;306(8):466–468. doi: 10.1056/NEJM198202253060807. [DOI] [PubMed] [Google Scholar]
- Swann R. A., Peel M. M., Rouch G. J. Isolation of Legionella pneumophila from hospital water systems in Victoria. Med J Aust. 1982 Sep 4;2(5):226–228. doi: 10.5694/j.1326-5377.1982.tb124341.x. [DOI] [PubMed] [Google Scholar]
- Tobin J. O., Bartlett C. L., Waitkins S. A., Barrow G. I., Macrae A. D., Taylor A. G., Fallon R. J., Lynch F. R. Legionnaires' disease: further evidence to implicate water storage and distribution systems as sources. Br Med J (Clin Res Ed) 1981 Feb 14;282(6263):573–573. doi: 10.1136/bmj.282.6263.573. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tobin J. O., Beare J., Dunnill M. S., Fisher-Hoch S., French M., Mitchell R. G., Morris P. J., Muers M. F. Legionnaires' disease in a transplant unit: isolation of the causative agent from shower baths. Lancet. 1980 Jul 19;2(8186):118–121. doi: 10.1016/s0140-6736(80)90005-7. [DOI] [PubMed] [Google Scholar]
- Tobin J. O., Swann R. A., Bartlett C. L. Isolation of Legionella pneumophila from water systems: methods and preliminary results. Br Med J (Clin Res Ed) 1981 Feb 14;282(6263):515–517. doi: 10.1136/bmj.282.6263.515. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wadowsky R. M., Butler L. J., Cook M. K., Verma S. M., Paul M. A., Fields B. S., Keleti G., Sykora J. L., Yee R. B. Growth-supporting activity for Legionella pneumophila in tap water cultures and implication of hartmannellid amoebae as growth factors. Appl Environ Microbiol. 1988 Nov;54(11):2677–2682. doi: 10.1128/aem.54.11.2677-2682.1988. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wadowsky R. M., Yee R. B. Glycine-containing selective medium for isolation of Legionellaceae from environmental specimens. Appl Environ Microbiol. 1981 Nov;42(5):768–772. doi: 10.1128/aem.42.5.768-772.1981. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Wadowsky R. M., Yee R. B., Mezmar L., Wing E. J., Dowling J. N. Hot water systems as sources of Legionella pneumophila in hospital and nonhospital plumbing fixtures. Appl Environ Microbiol. 1982 May;43(5):1104–1110. doi: 10.1128/aem.43.5.1104-1110.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Yee R. B., Wadowsky R. M. Multiplication of Legionella pneumophila in unsterilized tap water. Appl Environ Microbiol. 1982 Jun;43(6):1330–1334. doi: 10.1128/aem.43.6.1330-1334.1982. [DOI] [PMC free article] [PubMed] [Google Scholar]