Skip to main content
The BMJ logoLink to The BMJ
. 1989 Aug 12;299(6696):427–431. doi: 10.1136/bmj.299.6696.427

Carbohydrate deficient transferrin: a marker for alcohol abuse.

A Kapur 1, G Wild 1, A Milford-Ward 1, D R Triger 1
PMCID: PMC1837301  PMID: 2571374

Abstract

OBJECTIVE--To assess the value of serum carbohydrate deficient transferrin as detected by isoelectric focusing on agarose as an indicator of alcohol abuse. DESIGN--Coded analysis of serum samples taken from patients with carefully defined alcohol intake both with and without liver disease. Comparison of carbohydrate deficient transferrin with standard laboratory tests for alcohol abuse. SETTING--A teaching hospital unit with an interest in general medicine and liver disease. PATIENTS--22 "Self confessed" alcoholics admitting to a daily alcohol intake of at least 80 g for a minimum of three weeks; 15 of the 22 self confessed alcoholics admitted to hospital for alcohol withdrawal; 68 patients with alcoholic liver disease confirmed by biopsy attending outpatient clinics and claiming to be drinking less than 50 g alcohol daily; 47 patients with non-alcoholic liver disorders confirmed by biopsy; and 38 patients with disorders other than of the liver and no evidence of excessive alcohol consumption. INTERVENTION--Serial studies performed on the 15 patients undergoing alcohol withdrawal in hospital. MAIN OUTCOME measure--Determination of relative value of techniques for detecting alcohol abuse. RESULTS--Carbohydrate deficient transferrin was detected in 19 of the 22 (86%) self confessed alcohol abusers, none of the 47 patients with non-alcoholic liver disease, and one of the 38 (3%) controls. Withdrawal of alcohol led to the disappearance of carbohydrate deficient transferrin at a variable rate, though in some subjects it remained detectable for up to 15 days. Carbohydrate deficient transferrin was considerably superior to the currently available conventional markers for alcohol abuse. CONCLUSION--As the technique is fairly simple, sensitive, and inexpensive we suggest that it may be valuable in detecting alcohol abuse.

Full text

PDF
427

Images in this article

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Chalmers D. M., Rinsler M. G., MacDermott S., Spicer C. C., Levi A. J. Biochemical and haematological indicators of excessive alcohol consumption. Gut. 1981 Dec;22(12):992–996. doi: 10.1136/gut.22.12.992. [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Christmore D. S., Kelly R. C., Doshier L. A. Improved recovery and stability of ethanol in automated headspace analysis. J Forensic Sci. 1984 Oct;29(4):1038–1044. [PubMed] [Google Scholar]
  3. Lewis K. O., Paton A. ABC of alcohol: tools of detection. Br Med J (Clin Res Ed) 1981 Dec 5;283(6305):1531–1532. doi: 10.1136/bmj.283.6305.1531. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Poupon R. E., Papoz L., Sarmini H., Elinck R. A study of the microheterogeneity of transferrin in cirrhotic patients. Clin Chim Acta. 1985 Oct 15;151(3):245–251. doi: 10.1016/0009-8981(85)90087-7. [DOI] [PubMed] [Google Scholar]
  5. Skrede S., Blomhoff J. P., Gjone E. Biochemical features of acute and chronic hepatitis. Ann Clin Res. 1976 Jun;8(3):182–199. [PubMed] [Google Scholar]
  6. Stibler H., Borg S., Allgulander C. Clinical significance of abnormal heterogeneity of transferrin in relation to alcohol consumption. Acta Med Scand. 1979;206(4):275–281. doi: 10.1111/j.0954-6820.1979.tb13510.x. [DOI] [PubMed] [Google Scholar]
  7. Stibler H., Kjellin K. G. Isoelectric focusing and electrophoresis of the CSF proteins in tremor of different origins. J Neurol Sci. 1976 Dec;30(2-3):269–285. doi: 10.1016/0022-510x(76)90133-7. [DOI] [PubMed] [Google Scholar]
  8. Storey E. L., Anderson G. J., Mack U., Powell L. W., Halliday J. W. Desialylated transferrin as a serological marker of chronic excessive alcohol ingestion. Lancet. 1987 Jun 6;1(8545):1292–1294. doi: 10.1016/s0140-6736(87)90544-7. [DOI] [PubMed] [Google Scholar]
  9. Trowbridge E. A., Reardon D. M., Bradey L., Hutchinson D., Warren C. W. Automated haematology: construction of univariate reference ranges for blood cell count and size. Med Lab Sci. 1989 Jan;46(1):23–32. [PubMed] [Google Scholar]
  10. Whitfield J. B., Hensley W. J., Bryden D., Gallagher H. Some laboratory correlates of drinking habits. Ann Clin Biochem. 1978 Nov;15(6):297–303. doi: 10.1177/000456327801500171. [DOI] [PubMed] [Google Scholar]
  11. van Eijk H. G., van Noort W. L., Dubelaar M. L., van der Heul C. The microheterogeneity of human transferrins in biological fluids. Clin Chim Acta. 1983 Aug 15;132(2):167–171. doi: 10.1016/0009-8981(83)90244-9. [DOI] [PubMed] [Google Scholar]

Articles from BMJ : British Medical Journal are provided here courtesy of BMJ Publishing Group

RESOURCES