Skip to main content
British Medical Journal logoLink to British Medical Journal
. 1967 Apr 8;2(5544):88–91. doi: 10.1136/bmj.2.5544.88

Cryoprecipitate and the plastic blood-bag system: provision of adequate replacement therapy for routine treatment of haemophilia.

E Bennett, K M Dormandy, W G Churchill, A R Coward, M Smith, T E Cleghorn
PMCID: PMC1841290  PMID: 6020855

Full text

PDF
88

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. ANSTALL H. B., GROVE-RASMUSSEN M., SHAW R. S. Optimal conditions for storage of fresh frozen plasma. Transfusion. 1961 Mar-Apr;1:87–93. doi: 10.1111/j.1537-2995.1961.tb00018.x. [DOI] [PubMed] [Google Scholar]
  2. Bennett E., Dormandy K. Pool's cryoprecipitate and exhausted plasma in the treatment of von Willebrand's disease and factor-XI deficiency. Lancet. 1966 Oct 1;2(7466):731–732. doi: 10.1016/s0140-6736(66)92985-0. [DOI] [PubMed] [Google Scholar]
  3. Brown D. L., Hardisty R. M., Kosoy M. H., Bracken C. Antihaemophilic globulin: preparation by an improved cryoprecipitation method and clinical use. Br Med J. 1967 Apr 8;2(5544):79–85. doi: 10.1136/bmj.2.5544.79. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. HARDISTY R. M., MACPHERSON J. C. A one-stage factor VIII (antihaemophilic globulin) assay and its use on venous and capillary plasma. Thromb Diath Haemorrh. 1962 May 15;7:215–228. [PubMed] [Google Scholar]
  5. KLIMAN A., SCHWAB P. J. Plasmapheresis with simple equipment. Am J Clin Pathol. 1961 Oct;36:379–382. doi: 10.1093/ajcp/36.4_ts.379. [DOI] [PubMed] [Google Scholar]
  6. Pool J. G., Shannon A. E. Production of high-potency concentrates of antihemophilic globulin in a closed-bag system. N Engl J Med. 1965 Dec 30;273(27):1443–1447. doi: 10.1056/NEJM196512302732701. [DOI] [PubMed] [Google Scholar]
  7. Preston A. E. The factor-8 activity in fresh and stored plasma. Br J Haematol. 1967 Jan;13(1):42–59. doi: 10.1111/j.1365-2141.1967.tb08693.x. [DOI] [PubMed] [Google Scholar]
  8. Simson L. R., Oberman H. A., Penner J. A., Lien D. M., Warner C. L. A method for preparing plasma factor 8 (antihemophilic globulin) concentrate. Am J Clin Pathol. 1966 Apr;45(4):373–376. doi: 10.1093/ajcp/45.4.373. [DOI] [PubMed] [Google Scholar]
  9. WALTER C. W. A new technic for collection, storage, and administration of unadulterated whole blood. Surg Forum. 1950:483–490. [PubMed] [Google Scholar]
  10. WALTER C. W., BUTTON L. N., RITTS R. E., Jr An evaluation of human blood processed in plastic transfusion equipment. Surg Gynecol Obstet. 1957 Sep;105(3):365–369. [PubMed] [Google Scholar]

Articles from British Medical Journal are provided here courtesy of BMJ Publishing Group

RESOURCES