Skip to main content
Applied Microbiology logoLink to Applied Microbiology
. 1975 Jul;30(1):58–65. doi: 10.1128/am.30.1.58-65.1975

Comparative Study of Four Microporous Filters for Concentrating Viruses from Drinking Water

Walter Jakubowski 1, William F Hill Jr 1, Norman A Clarke 1
PMCID: PMC187114  PMID: 167662

Abstract

Four microporous virus-adsorbent filter media for recovering low levels of virus from 380 liters of drinking water were compared. In addition, two of the filter media were compared with 1,900 liters of drinking water. The filter media evaluated were MF nitrocellulose membranes (293 mm), AA Cox M-780 epoxy-fiberglass-asbestos disks (267 mm), K-27 yarn-wound fiberglass cartridges + AA Cox M-780 disks (127 mm), and Balston epoxy-fiberglass tubes (24.5 by 63.5 mm). The filters were used to concentrate seeded poliovirus from 380 liters of finished drinking water. Sodium thiosulfate was added to the drinking water to neutralize chlorine, and hydrochloric acid was added to adjust the pH to 3.5. Virus was eluted from the filters with glycine-NaOH buffer at pH 11.5. In terms of virus recovery efficiency, the filter media ranked Balston > Cox 267-mm > MF 293-mm ≃ K-27 + Cox 127-mm, but differences were slight. The Balston filters and holders were also superior to the other systems in terms of size, weight, cost, and handling factors. Experiments with 2- and 8-μm porosity Balston filters showed no statistically significant difference in virus recovery. Virus was readily detected by the Balston and the MF 293-mm systems at input levels of 12 to 22 PFU/1,900 liters. Preliminary experiments indicated that an elution pH lower than 11.5 may be satisfactory.

Full text

PDF

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Anderson N. G., Waters D. A., Nunley C. E., Gibson R. F., Schilling R. M., Denny E. C., Cline G. B., Babelay E. F., Perardi T. E. K-series centrifuges. I. Development of the K-II continuous-sample-flow-with-banding centrifuge system for vaccine purification. Anal Biochem. 1969 Dec;32(3):460–494. doi: 10.1016/s0003-2697(69)80014-x. [DOI] [PubMed] [Google Scholar]
  2. Berg G., Dahling D. R., Berman D. Recovery of small quantities of viruses from clean waters on cellulose nitrate membrane filters. Appl Microbiol. 1971 Oct;22(4):608–614. doi: 10.1128/am.22.4.608-614.1971. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Hill W. F., Jr, Akin E. W., Benton W. H., Mayhew C. J., Jakubowski W. Apparatus for conditioning unlimited quantities of finished waters for enteric virus detection. Appl Microbiol. 1974 Jun;27(6):1177–1178. doi: 10.1128/am.27.6.1177-1178.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Hill W. F., Jr, Akin E. W., Benton W. H., Mayhew C. J., Metcalf T. G. Recovery of poliovirus from turbid estuarine water on microporous filters by the use of celite. Appl Microbiol. 1974 Mar;27(3):506–512. doi: 10.1128/am.27.3.506-512.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
  5. Jakubowski W., Hoff J. C., Anthony N. C., Hill W. F., Jr Epoxy-fiberglass adsorbent for concentrating viruses from large volumes of potable water. Appl Microbiol. 1974 Sep;28(3):501–502. doi: 10.1128/am.28.3.501-502.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Liu O. C., Brashear D. A., Seraichekas H. R., Barnick J. A., Metcalf T. G. Virus in water. I. A preliminary study on a flow-through gauze sampler for recovering virus from waters. Appl Microbiol. 1971 Mar;21(3):405–410. doi: 10.1128/am.21.3.405-410.1971. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Metcalf T. G., Wallis C., Melnick J. L. Environmental factors influencing isolation of enteroviruses from polluted surface waters. Appl Microbiol. 1974 May;27(5):920–926. doi: 10.1128/am.27.5.920-926.1974. [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Sobsey M. D., Wallis C., Henderson M., Melnick J. L. Concentration of enteroviruses from large volumes of water. Appl Microbiol. 1973 Oct;26(4):529–534. doi: 10.1128/am.26.4.529-534.1973. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Sweet B. H., McHale J. S., Hardy K. J., Klein E. Concentration of virus from water by electro-osmosis and forced-flow electrophoresis. Prep Biochem. 1971 Jan;1(1):77–89. doi: 10.1080/00327487108081931. [DOI] [PubMed] [Google Scholar]
  10. Ver B. A., Melnick J. L., Wallis C. Efficient filtration and sizing of viruses with membrane filters. J Virol. 1968 Jan;2(1):21–25. doi: 10.1128/jvi.2.1.21-25.1968. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Wallis C., Henderson M., Melnick J. L. Enterovirus concentration on cellulose membranes. Appl Microbiol. 1972 Mar;23(3):476–480. doi: 10.1128/am.23.3.476-480.1972. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Applied Microbiology are provided here courtesy of American Society for Microbiology (ASM)

RESOURCES