The glomerular filtration rate (GFR) was estimated using 125I-iothalamate by the cumulative integral method in 95 subjects — 16 normal subjects and 79 patients with suspected or proved renal disease. This method is accurate, simple to perform and theoretically sound. It minimizes errors due to transit time and bladder storage. The normal range of GFR was determined to be 71 ± 10 (two standard deviations) ml/min/m2. In 66 patients serum creatinine levels were compared with the GFR value expressed per square metre. For any given serum creatinine level there is a wide range of GFR values. A serum creatinine value in the normal range, i.e. between 0.7 and 1.3 mg/dl, cannot be used to predict the patient's GFR. The micro blood sampling technique makes this method particularly useful in infants.

Full text

PDF
1358

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Arant B. S., Jr, Edelmann C. M., Jr, Spitzer A. The congruence of creatinine and inulin clearances in children: use of the Technicon AutoAnalyzer. J Pediatr. 1972 Sep;81(3):559–561. doi: 10.1016/s0022-3476(72)80191-4. [DOI] [PubMed] [Google Scholar]
  2. Blaufox M. D., Merrill J. P. Simplified hippuran clearance. Measurement of renal function in man with simplified hippuran clearances. Nephron. 1966;3(5):274–281. doi: 10.1159/000179542. [DOI] [PubMed] [Google Scholar]
  3. Cohen M. L., Smith F. G., Jr, Mindell R. S., Vernier R. L. A simple, reliable method of measuring glomerular filtration rate using single, low dose sodium iothalamate I-131. Pediatrics. 1969 Mar;43(3):407–415. [PubMed] [Google Scholar]
  4. Cole B. R., Giangiacomo J., Ingelfinger J. R., Robson A. M. Measurement of renal function without urine collection. A critical evaluation of the constant-infusion technic for determination of inulin and para-aminohippurate. N Engl J Med. 1972 Nov 30;287(22):1109–1114. doi: 10.1056/NEJM197211302872202. [DOI] [PubMed] [Google Scholar]
  5. Dodge W. F., Travis L. B., Daeschner C. W. Comparison of endogenous creatinine clearance with inulin clearance. Am J Dis Child. 1967 Jun;113(6):683–692. doi: 10.1001/archpedi.1967.02090210097010. [DOI] [PubMed] [Google Scholar]
  6. Harries J. D., Mildenberger R. R., Malowany A. S., Drummond K. N. A computerized cummulative integral method for the precise measurement of the glomerular filtration rate. 1. Proc Soc Exp Biol Med. 1972 Sep;140(4):1148–1155. doi: 10.3181/00379727-140-36630. [DOI] [PubMed] [Google Scholar]
  7. Riep R. J., Nelp W. B. Mechanism of excretion of radioiodinated sodium iothalamate. Radiology. 1969 Oct;93(4):807–811. doi: 10.1148/93.4.807. [DOI] [PubMed] [Google Scholar]
  8. Sakai T., Leumann E. P., Holliday M. A. Single injection clearance in children. Pediatrics. 1969 Dec;44(6):905–911. [PubMed] [Google Scholar]
  9. Sigman E. M., Elwood C. M., Knox F. The measurement of glomerular filtration rate in man with sodium iothalamate 131-I (Conray). J Nucl Med. 1966 Jan;7(1):60–68. [PubMed] [Google Scholar]

Articles from Canadian Medical Association Journal are provided here courtesy of Canadian Medical Association

RESOURCES