Technique for Avoiding Femoral Osteotomy in Removing Uncemented Implants

MM Mullins 1, P Piriou 1, T Judet 1
PMCID: PMC1963751

The removal of distally fixed, uncemented, femoral components is one of the major challenges in revision orthopaedic surgery. Saw blades often have insufficient length to reach the distal part of the component and long chisels are inevitably wider proximally and can cause metaphyseal damage. We report the use of Illizarov wires passed serially using a power driver between the implant and host bone to divide the distal bone implant interface (Fig. 1). Their flexibility minimises damage to the proximal femur and the femoral component can be removed without resorting to femoral osteotomy and the attendant increased morbidity and complications.

Figure 1.

Figure 1

Illizarov wire passing between implant and bone to free prosthesis distally.


Articles from Annals of The Royal College of Surgeons of England are provided here courtesy of The Royal College of Surgeons of England