Skip to main content
Annals of The Royal College of Surgeons of England logoLink to Annals of The Royal College of Surgeons of England
. 2005 Nov;87(6):445–448. doi: 10.1308/003588405X71036

Blood ordering protocol based on proposed surgical implant in fractured neck of femur patients.

D G Morritt 1, A N Morritt 1, S P Kelley 1, M H Stone 1
PMCID: PMC1964110  PMID: 16263014

Abstract

INTRODUCTION: Fractured neck of femur patients frequently require blood transfusion. To improve the efficiency of blood ordering, we present a protocol which orders blood specific for the proposed surgical implant. PATIENTS AND METHODS: A retrospective audit over a 1-year period was performed. Patients were divided into six groups dependent on proposed surgical implant. The mean postoperative drop in haemoglobin concentration, the cross-match to transfusion ratio and transfusion indexes were calculated. RESULTS: Statistically significant differences in blood loss were found dependent on implant used. Using guidelines created by the British Committee for Standards in Haematology on the implementation of a maximum surgical blood ordering schedule, a new protocol for blood ordering based on proposed surgical implant was created. CONCLUSIONS: In fractured neck of femur patients awaiting operation, the type of implant can be used to anticipate blood loss and as a guide to blood ordering.


Articles from Annals of The Royal College of Surgeons of England are provided here courtesy of The Royal College of Surgeons of England